Nurdan Yildirim

Nurdan Yildirim

Auto-generated profile, based on publicly available information

Nurdan Yildirim

Department of Mechanical Engineering Yaşar University İzmir Turkey

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
NYNurdan Yildirim
Nurdan Yildirim
LBLevent Bilir
Levent Bilir

1 October 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
NYNurdan Yildirim
Nurdan Yildirim
SGSeda Genc
Seda Genc

1 August 2010 in Energy
Verified
Journal Article
Open access
NYNurdan Yildirim
Nurdan Yildirim
MTMacit Toksoy
Macit Toksoy
GÜLDEN GÖKCEN AKKURTGÜLDEN GÖKCEN AKKURT
GÜLDEN GÖKCEN AKKURT
Geothermal district heating system design consists of two parts: heating system and piping network design. District heating system design and a case study for a university campus is given in Yildirim et al. [1] in detail. In this study, piping network design optimisation is evaluated based on heat centre location depending upon the cost and common design parameters of piping networks which are pipe materials, target pressure loss (TPL) per unit length of pipes and installation type. Then a case study for the same campus is presented. © 2010 Elsevier Ltd


1 July 2017 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
LBLevent Bilir
Levent Bilir
NYNurdan Yildirim
Nurdan Yildirim

1 October 2009 in Applied Thermal Engineering
Verified
Journal Article
Open access
NON. Yildirim Ozcan
N. Yildirim Ozcan
GGG. Gokcen
G. Gokcen
Geothermal fluids contain non-condensable gases (NCGs) at various amounts. NCGs flow to a conventional geothermal power plant (GPP) with steam phase and should be withdrawn from the condenser by a gas removal system to prevent increase in condenser pressure and consequently decrease in power generation. Therefore, to remove NCGs from the system is critical especially at high NCG fractions. In this study, the net power output and specific steam consumption of a single-flash GPP is evaluated depending on the separator pressure, NCG fraction and wet bulb temperature of the environment, and three different conventional gas removal options which are two-stage steam jet ejector system, two-stage hybrid system and two-stage compressor system. A simulation code is written in EES to model the plant for each option. The model uses the data of Kizildere Geothermal Power Plant (KGPP) - Turkey, which is a single-flash plant with extremely high NCG fraction, to allow a comparison between the results of the modelling and the operational data of an actual single-flash GPP. Under given conditions, thermodynamic analysis resulted that NCG fraction is the most significant factor on GPP performance and the compressor system is the most efficient and robust option where the influence of the NCG fraction is limited