Priscila Maria Nascimento Martins de Albuquerque

Priscila Maria Nascimento Martins de Albuquerque

Auto-generated profile, based on publicly available information

Priscila Maria Nascimento Martins de Albuquerque

Department of Physiotherapy, Federal University of Pernambuco, Recife, Pernambuco, Brazil

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Manipulative and Physiological Therapeutics
Verified
Journal Article
Closed access
PAPriscila Maria Nascimento Martins de Albuquerque
Priscila Maria Nascimento Martins de Albuquerque
GAGeisa Guimarães de Alencar
Geisa Guimarães de Alencar
DODaniela Araújo de Oliveira
Daniela Araújo de Oliveira
GSGisela Rocha de Siqueira
Gisela Rocha de Siqueira
The aim of this study was to examine and interpret the concordance, accuracy, and reliability of photogrammetric protocols available in the literature for evaluating cervical lordosis in an adult population aged 18 to 59 years. A systematic search of 6 electronic databases (MEDLINE via PubMed, LILACS, CINAHL, Scopus, ScienceDirect, and Web of Science) located studies that assessed the reliability and/or concordance and/or accuracy of photogrammetric protocols for evaluating cervical lordosis, compared with radiography. Articles published through April 2016 were selected. Two independent reviewers used a critical appraisal tool (QUADAS and QAREL) to assess the quality of the selected studies. Two studies were included in the review and had high levels of reliability (intraclass correlation coefficient: 0.974-0.98). Only 1 study assessed the concordance between the methods, which was calculated using Pearson's correlation coefficient. To date, the accuracy of photogrammetry has not been investigated thoroughly. We encountered no study in the literature that investigated the accuracy of photogrammetry in diagnosing hyperlordosis of cervical spine. However, both current studies report high levels of intra- and interrater reliability. To increase the level of evidence of photogrammetry in the evaluation of cervical lordosis, it is necessary to conduct further studies using a larger sample to increase the external validity of the findings.

1 March 2022 in Journal of Manipulative and Physiological Therapeutics
Verified
Journal Article
Closed access
PAPriscila M.N.M. Albuquerque
Priscila M.N.M. Albuquerque
ESEricka P.C. Da Silva
Ericka P.C. Da Silva
TMThania M. de S. Melo
Thania M. de S. Melo
EMEduardo J.N. Montenegro
Eduardo J.N. Montenegro
DODaniella A. de Oliveira
Daniella A. de Oliveira
GSGisela Rocha de Siqueira
Gisela Rocha de Siqueira
The purpose of this study was to determine the accuracy and intrarater reliability of a palpatory protocol based on a combination of 3 palpatory methods to identify both the C7 spinous process (C7 SP) and the factors that affect the errors and inaccuracy of palpation. Twenty-five women between the ages of 18 and 60 years were submitted to a palpation protocol of the C7 SP, and a radiopaque marker was fixed on the skin at the possible location of the vertebrae. A radiograph and a photograph of the cervical spine were obtained in the same posture by a first rater. A second rater performed the same palpation protocol and took a second photograph. The accuracy and measurement error of the palpation protocol of C7 SP were assessed through radiographic images. The inter-rater reliability was estimated by the interclass correlation coefficient and assessed using photographs of each rater. The Pearson's correlation coefficients (r), the Fisher exact test, and the χ2 test were used to identify the factors associated with the error and inaccuracy of palpation. Accuracy of the C7 palpation was 76% with excellent reliability (interclass correlation coefficient = 0.99). There was a moderate correlation between weight and the measurement of palpation error (r = -0.6; P = .003). One hundred percent of inaccuracy palpation was related to the increased soft-tissue thickness (P = .005) in the cervical region. The palpation protocol described in this study was accurate and presented excellent reliability in identifying the C7 SP. Increased weight and dorsocervical fat pad were associated to error and palpation inaccuracy, respectively.