Saran Tantavisut

Saran Tantavisut

Auto-generated profile, based on publicly available information

Saran Tantavisut

Hip Fracture Research Unit, Department of Orthopaedics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
STSaran Tantavisut
Saran Tantavisut
ATAree Tanavalee
Aree Tanavalee
SHSittisak Honsawek
Sittisak Honsawek
TSTanyawan Suantawee
Tanyawan Suantawee
SNSrihatach Ngarmukos
Srihatach Ngarmukos
JCJohn J. Callaghan
John J. Callaghan
This study was performed to evaluate the antioxidative and anti-inflammatory effects of vitamin E on oxidative stress in the plasma, synovial fluid, and synovial tissue of patients with knee osteoarthritis. Seventy-two patients with late-stage knee osteoarthritis scheduled for total knee arthroplasty were randomized to take oral placebo (Group A) or 400 IU of vitamin E (Group B) once a day for 2 months before undergoing surgery. The blood levels of endpoints indicating oxidative stress or antioxidant capacity, Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index score (WOMAC), and adverse effects were compared before and after the intervention between the two groups. At surgery, these redox endpoints and histological findings were compared between the synovial fluid and synovial tissue. In blood samples, the pre-intervention of oxidative stress and antioxidative capacity were not different between Group A and Group B. In post-intervention blood samples, the Malondialdehyde (Group A 1.34 ± 0.10, Group B 1.00 ± 0.09, p < 0.02), Alpha tocopherol (Group A 15.92 ± 1.08, Group B 24.65 ± 1.47, p < 0.01) and Trolox equivalent antioxidant capacity (Group A 4.22 ± 0.10, Group B 5.04 ± 0.10, 0 < 0.01) were significantly different between Group A and Group B. In synovial fluid samples, the Malondialdehyde (Group A 1.42 ± 0.12, Group B 1.06 ± 1.08, p 0.01), Alphatocopherol (Group A 4.51, Group B 7.03, p < 0.01), Trolox equivalent antioxidant capacity (Group A, 1.89 ± 0.06, Group B 2.19 ± 0.10) were significantly different between Group A and Group B. The pre-intervention WOMAC score and KSS score were not different between Group A and Group B. The post-intervention WOMAC score was significantly improved in all categories in Group B (Pain: Group A 27.26 ± 0.89, Group B 19.19 ± 1.43, p < 0.01; Stiffness: Group A 8.23 ± 0.79, Group B 5.45 ± 0.73, p 0.01; Function: Group A 94.77 ± 4.22, Group B 72.74 ± 6.55, p < 0.01). The post-intervention KSS score was significantly improved in all categories in Group B (Clinical: Group A 25.31 ± 14.33, Group B 33.52 ± 16.96, p < 0.01; Functional: Group A 41.43 ± 16.11, Group B 51.61 ± 19.60, p 0.02). Significantly fewer synovial tissue cells were stained with nitrotyrosine and hematoxylin–eosin in Group B than in Group A. There were no differences in adverse effects or surgical complications between the groups. Vitamin E is an effective antioxidant that can improve clinical symptoms and reduce oxidative stress conditions in patients with late-stage knee osteoarthritis. This research project had been approved for registration at Thai Clinical Trials Registry (TCTR) since 2016–08-28 11:26:32 (Retrospective registered). The TCTR identification number is TCTR20160828001 .

1 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
HCH-thaichnok Chunate
H-thaichnok Chunate
JKJirapon Khamwannah
Jirapon Khamwannah
AAAbdul Azeez Abdu Aliyu
Abdul Azeez Abdu Aliyu
STSaran Tantavisut
Saran Tantavisut
CPChedtha Puncreobutr
Chedtha Puncreobutr
BLBoonrat Lohwongwatana
Boonrat Lohwongwatana
The aim of this study is to synthesize Titania nanotubes (TNTs) on the 3D-printed Ti-6Al-4V surface and investigate the loading of antibacterial vancomycin drug dose of 200 ppm for local drug treatment application for 24 h. The antibacterial drug release from synthesized nanotubes evaluated via the chemical surface measurement and the linear fitting of Korsmeyer–Peppas model was also assessed. The TNTs were synthesized on the Ti-6Al-4V surface through the anodization process at different anodization time. The TNTs morphology was characterized using field emission scanning electron microscope (FESEM). The wettability and the chemical composition of the Ti-6Al-4V surface and the TNTs were assessed using the contact angle meter, Fourier transform infrared spectrophotometer (FTIR) and the X-ray photoelectron spectroscopy (XPS). The vancomycin of 200 ppm release behavior under controlled atmosphere was measured by the high-performance liquid chromatography (HPLC) and hence, the position for retention time at 2.5 min was ascertained. The FESEM analysis confirmed the formation of nanostructured TNTs with vertically oriented, closely packed, smooth and unperforated walls. The maximum cumulative vancomycin release of 34.7% (69.5 ppm) was recorded at 24 h. The wetting angle of both Ti-6Al-4V implant and the TNTs were found below 90 degrees. This confirmed their excellent wettability.

30 November 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
STSaran Tantavisut
Saran Tantavisut
JLJiraporn Leanpolchareanchai
Jiraporn Leanpolchareanchai
AWAmaraporn Wongrakpanich
Amaraporn Wongrakpanich
Background and purpose: The purpose of this study was to investigate the effect of incorporating chitosan (Ch) and chitosan oligosaccharides (ChO) into the commercially premixed antibiotic-loaded bone cement (ALBC). We compare antibiotic release profiles, antibacterial activity, and mechanical properties among different ALBC formulations. The hypothesis was that increasing the amount of Ch and ChO in the cement mixture would increase the antibiotics released and bacterial control. ALBC mixed with Ch or ChO may create a greater effect due to its superior dissolving property.Materials and methods: The bone cement samples used in this project were made from Copal®G+V composed of vancomycin and gentamicin. To prepare the Ch and the ChO mixed bone cement samples, different amounts of Ch and ChO were added to the polymethylmethacrylate matrix with three concentrations (1%, 5%, and 10%). Drug elution assay, antimicrobial assay,in vitrocytotoxicity, and mechanical properties were conducted.Results: Bone cement samples made from Copal®G+V alone or combined with Ch or ChO can release vancomycin and gentamicin into the phosphate-buffered saline. Mixing ChO into the bone cements can increase the amount of drug released more than Ch. ChO 10% gave the highest amount of antibiotics released. All samples showed good antibacterial properties with good biocompatibilityin vitro. The microhardness values of the Ch and ChO groups increased significantly compared to the control group. In all groups tested, the microhardness of bone cements was reduced after the drug eluted out. However, this reduction of the Ch and ChO groups was in line with the control.Interpretation: Various attempts have been made to improve the ALBC efficacy. In our study, the best bone cement formulation was bone cement mixed with ChO (10%), which had the highest drug release profiles, was biocompatible, and contained antibacterial properties with acceptable mechanical properties. This phenomenon could result from the superior water solubility of the ChO. When ChO leaves the bone cement specimens, it generates pores that could act as a path that exposes the bone cement matrix to the surrounding medium, increasing antibiotic elution. From all above, ChO is a promising substance that could be added to ALBC in order to increase the drug elution rate. However, morein vitroandin vivoexperiments are needed before being used in the clinic.

15 February 2022 in Knee Surgery & Related Research
Verified
Journal Article
Open access
PDF file
STS. Tantavisut
S. Tantavisut
CAC. Amarase
C. Amarase
SNS. Ngarmukos
S. Ngarmukos
CTC. Tanavalee
C. Tanavalee
ATA. Tanavalee
A. Tanavalee
Background: During revision total knee arthroplasty (TKA), knee joint line restoration may be difficult due to bone loss or structural changes. Although bony landmarks are consistent and can be used as references, there are limited data in Asian patients. We studied the knee joint line related to bony landmarks of the knee in a Thai population. Materials and methods: Magnetic resonance imaging (MRI) of 140 healthy knees of Thai patients (70 males, 70 females) were investigated. In all knees, a perpendicular line from knee joint line to the medial epicondyle (distance A) and the lateral epicondyle (distance B) in the coronal plane were measured. In the sagittal plane, a perpendicular line from the knee joint line to the fibular head (distance C), the tibial tubercle (distance D), and the inferior patellar pole (distance E) were measured. The femoral transepicondylar width (FW) was measured along the transepicondylar axis. The ratios of distances A, B, C, D, and E related to FW were evaluated (epicondylar ratio). Results: The mean and standard deviation (SD) of distances A, B, C, D, E, and FW were 27.1 ± 2.7 mm, 21.7 ± 2.5 mm, 12.6 ± 3 mm, 21.3 ± 3.6 mm, 7.6 ± 4.8 mm, and 76.7 ± 3.99, respectively. There was wide variation of measured values, with statistically significant differences between genders in distances A, B, C, and FW. The mean and SD of epicondylar ratios A/FW, B/FW, C/FW, D/FW, and E/FW were 0.35 ± 0.02, 0.29 ± 0.02, 0.16 ± 0.05, 0.28 ± 0.04, and 0.09 ± 0.04, respectively. All epicondylar ratios demonstrated less variation than all measured distances, with statistical differences between genders in the A/FW and D/FW ratios. However, the B/FW ratio had the highest consistent mean value. In addition, it had narrower SD than the rest (0.29 ± 0.02; range, 0.22–0.33). Conclusions: In Thai knees, the measured distances from bony landmarks to the knee joint line had higher variation than the epicondylar ratio. Among all studied epicondylar ratios, the ratio between lateral epicondyle to joint line distance (distance B)/FW demonstrated the narrowest range of mean and SD values; therefore, this could be the most reliable landmark for intraoperative knee joint line verification by multiplying the FW of the patient by 0.29 to get distance B in that patient.

1 January 2025 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
SASanzhar Artykbay
Sanzhar Artykbay
PSPaweena Susantitaphong
Paweena Susantitaphong
STSaran Tantavisut
Saran Tantavisut
Artykbay S, et al. Clin Orthop Surg. 2025 Feb;17(1):16-28. https://doi.org/10.4055/cios24184

1 July 2025 in EFORT Open Reviews
Verified
Journal Article
Open access
STSaran Tantavisut
Saran Tantavisut
SASanzhar Artykbay
Sanzhar Artykbay
PTPasawiss Tangwiwat
Pasawiss Tangwiwat
PSPaweena Susantitaphong
Paweena Susantitaphong
Purpose: Methods: Results: Conclusion: