Elexis C. Baral

Elexis C. Baral

Auto-generated profile, based on publicly available information

Elexis C. Baral

Hospital for Special Surgery, New York, NY

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in The Knee
Verified
Journal Article
Closed access
ACAlexander Bryant Christ
Alexander Bryant Christ
EBElexis Baral
Elexis Baral
CKChelsea Koch
Chelsea Koch
BSBeth E. Shubin Stein
Beth E. Shubin Stein
AVAlejandro Gonzalez Della Valle
Alejandro Gonzalez Della Valle
SSSabrina M. Strickland
Sabrina M. Strickland

20 January 2022 in Arthroplasty Today
Verified
Journal Article
Open access
RPRichard L. Purcell
Richard L. Purcell
EBElexis C. Baral
Elexis C. Baral
SSSean E. Slaven
Sean E. Slaven
TWTimothy M. Wright
Timothy M. Wright
GWGeoffrey H. Westrich
Geoffrey H. Westrich
Cementless total knee arthroplasty is gaining interest as total knee arthroplasty patients become younger, more active, and interested in long-term biologic fixation. New porous coatings have altered mechanical properties to improve bone osseointegration, although limited data exist on this topic. We measured the bone ongrowth on retrieved tibial trays to determine how demographic, radiographic, or implant design factors correlate with ongrowth. Twenty retrieved trays were assessed from 3 designs: Zimmer NexGen Trabecular Metal (n = 9), Stryker Triathlon Tritanium (n = 6), and Biomet Vanguard Regenerex (n = 5). Exclusion criteria included revision for aseptic loosening or early postoperative infection. Ongrowth on the tibial components and on corresponding pegs (if accessible) was assessed. The amount of osseointegration was reported as the bone directly opposed to the surface divided by the available area for ongrowth. Radiographs were reviewed for alignment and regions of biologic fixation. Bone ongrowth covered 65% ± 19% of the tibial tray surface and did not differ among manufacturers (P = .27). Medial pegs had less ongrowth than lateral pegs (39% vs 64%, P = .02). Vanguard medial pegs had less ongrowth than NexGen medial pegs (15% vs 61%, P = .03). Length of implantation was different between the NexGen (55 months) and Triathlon (24 months, P < .05) design only. Patient and radiographic data demonstrated no correlation with ongrowth. An average 65% of the porous tibial tray surface had ongrowth at revision. These values are consistent with manufacturing claims for excellent bone ongrowth for newer porous coatings.

1 March 2019 in Arthroplasty Today
Verified
Journal Article
Open access
UIUgonna Ihekweazu
Ugonna Ihekweazu
PCP. Maxwell Courtney
P. Maxwell Courtney
EBElexis C. Baral
Elexis C. Baral
MAMatthew S. Austin
Matthew S. Austin
AMAlexander S. McLawhorn
Alexander S. McLawhorn
In this series, we report the findings from four patients who presented with pain and mechanical symptoms after revision total knee arthroplasty with the DePuy Sigma TC3 RP prosthesis. Plain radiographs for each patient demonstrated failure of the femoral component at the modular junction of the femoral prosthesis. Retrieved implants at the time of surgery revealed fractures occurring exclusively at the femoral adapter bolt and the corresponding adapter. Retrieval analysis was performed on two of the four cases by visual light microscopy. Our findings suggest that the implants had suffered from fatigue fractures likely due to cyclic loading. This is the first case series to describe the failure mechanism and clinical scenarios contributing to failure of the femoral locking bolt and adapter sleeve in this prosthesis.

1 December 2017 in Arthroplasty Today
Verified
Journal Article
Open access
EBElexis C. Baral
Elexis C. Baral
AMAlexander S. McLawhorn
Alexander S. McLawhorn
TWTimothy M. Wright
Timothy M. Wright
ESEdwin P. Su
Edwin P. Su
A 58-year-old woman presented with onset of pain associated with a popping sound after a twisting motion 4 years after left total knee revision arthroplasty. She had a complex medical history, including a reported bone cement allergy, and presented to the hospital unable to bear weight. Plain radiographs revealed a broken femoral component, with the femoral metaphyseal sleeve separated from the distal articular component. During surgery, it was observed that the femoral adapter bolt and taper adapter had both fractured. Scanning electron microscopy of the fracture surfaces of the components confirmed that the implant had failed in fatigue, presumably due to high cyclic loads. Failure at this junction has not been described previously. In this type of knee design, we recommend supporting the distal articular component either with bone, augmentation, and/or bone cement to reduce the risk for this mode of failure.

28 February 2022 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
DLDavid C. Landy
David C. Landy
EBElexis C. Baral
Elexis C. Baral
HPHollis G. Potter
Hollis G. Potter
YCYu-Fen Chiu
Yu-Fen Chiu
PSPeter K. Sculco
Peter K. Sculco
MKMatthew F. Koff
Matthew F. Koff

21 February 2023 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
CKCynthia A. Kahlenberg
Cynthia A. Kahlenberg
EBElexis C. Baral
Elexis C. Baral
ASAarti A. Shenoy
Aarti A. Shenoy
PSPeter K. Sculco
Peter K. Sculco
MAMichael P. Ast
Michael P. Ast
ACAlberto V. Carli
Alberto V. Carli