Zakariyya Vali

Zakariyya Vali

Auto-generated profile, based on publicly available information

Zakariyya Vali

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester LE3 9QP, UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Ahmed AbdelrazikAhmed Abdelrazik
Ahmed Abdelrazik
MEMahmoud Eldesouky
Mahmoud Eldesouky
IAIbrahim Antoun
Ibrahim Antoun
ELEdward Yan Ming Lau
Edward Yan Ming Lau
AKAbdulmalik Koya
Abdulmalik Koya
GNG. André Andre Ng
G. André Andre Ng
Cardiac arrhythmias are a growing global health concern, and the need for accessible, continuous monitoring has driven rapid advancements in wearable technologies. This review explores the evolution, capabilities, and clinical impact of modern wearables for arrhythmia detection, including smartwatches, smart rings, ECG patches, and smart textiles. In light of the recent surge in commercially available wearables across all categories, this review offers a detailed comparative analysis of leading devices, evaluating cost, regulatory approval, model specifications, and system compatibility. Smartwatches and patches, in particular, show a strong performance in atrial fibrillation detection, with patches outperforming Holter monitors in long-term monitoring and diagnostic yield. This review highlights a paradigm shift toward patient-initiated diagnostics but also discusses challenges such as false positives, regulatory gaps, and healthcare integration. Overall, wearable devices hold significant promise for reshaping arrhythmia management through early detection and remote monitoring.

1 November 2022 in Current Cardiology Reviews
Verified
Journal Article
Closed access
PDF file
SPSusil Pallikadavath
Susil Pallikadavath
ZVZakariyya Vali
Zakariyya Vali
RPRoshan Patel
Roshan Patel
AMAkash Mavilakandy
Akash Mavilakandy
NPNicholas Peckham
Nicholas Peckham
GNG. André Andre Ng
G. André Andre Ng
Introduction: Exposure to air pollution is a recognised risk factor for cardiovascular disease and has been associated with supraventricular arrhythmias. The effect of air pollution on ventricular arrhythmias is less clear. This scoping review assessed the effects of particulate and gaseous air pollutants on the incidence of ventricular arrhythmias. Methods: MEDLINE and EMBASE databases were searched for studies assessing the effects of air pollutants on ventricular tachycardia and ventricular fibrillation. These pollutants were particulate matter (PM) 2.5, PM10, Nitrogen Dioxide (NO2), Carbon Monoxide (CO), Sulphur Dioxide (SO2), and Ozone (O3). Results: This review identified 27 studies: nine in individuals with implantable cardioverter defibrillators, five in those with ischaemic heart disease, and 13 in the general population. Those with ischaemic heart disease appear to have the strongest association with ventricular arrhythmias in both gaseous and particulate pollution, with all three studies assessing the effects of PM2.5 demonstrating some association with ventricular arrythmia. Results in the general and ICD population were less consistent. Conclusion: Individuals with ischaemic heart disease may be at an increased risk of ventricular arrhythmias following exposure to air pollution.

Verified
Journal Article
Open access
PDF file
IAIbrahim Antoun
Ibrahim Antoun
AKAhmed I. Kotb
Ahmed I. Kotb
ZVZakkariya Vali
Zakkariya Vali
Ahmed AbdelrazikAhmed Abdelrazik
Ahmed Abdelrazik
IKIvelin Koev
Ivelin Koev
GNG. André Andre Ng
G. André Andre Ng
Background: pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) improves health-related quality of life (QoL). This study compares QoL improvement after radiofrequency ablation (RF) and cryoballoon ablation (cryo) and assesses additional ablations’ role in QoL improvement. Methods: we evaluated the QoL of consecutive patients with first-time RF and cryo for PAF between January 2017 and June 2019. A combined EQ-VAS, AFEQT, and EQ-5D-3L paper questionnaire was sent to patients at baseline, 12, and 30 months after the procedure. Procedure and patient details were collected from medical notes. Results: the analysis included 207 patients, of which 127 (61%) had RF and 144 (70%) were males. RF patients had more additional ablations (52 [41%] versus 22 [28%], p = 0.01). There was a significant improvement from baseline to 12 months post-RF in AFEQT (43 ± 9 to 83 ± 7.8, p < 0.001), EQ-5D-3L (−0.01 ± 0.01 to 1.1 ± 0.02, p < 0.001), and EQ-VAS (51 ± 8 to 77 ± 13, p = 0.01). Similarly, an improvement at 12 months was observed after cryo in AFEQT (55 ± 11 to 77 ± 9, p < 0.001), EQ-5D-3L (−0.04 ± 0.03 to 1.3 ± 0.03, p < 0.001), and EQ-VAS (56 ± 7 to 85 ± 9, p = 0.01). QoL improvement was similar between RF and cryo. Additional ablations provided no additional QoL improvement compared to patients with PVI alone. Conclusions: Patients undergoing first-time PVI for PAF, RF, and cryo showed similar QoL improvement at 12 months, which was sustained at 30 months. Additional ablations did not provide further QoL benefits.

Verified
Journal Article
Open access
PDF file
IAIbrahim Antoun
Ibrahim Antoun
XLXin Li
Xin Li
AKAhmed I. Kotb
Ahmed I. Kotb
ZVZakkariya Vali
Zakkariya Vali
Ahmed AbdelrazikAhmed Abdelrazik
Ahmed Abdelrazik
GNG. André Andre Ng
G. André Andre Ng
Background: Pulmonary vein isolation (PVI) is an effective management method for paroxysmal atrial fibrillation (PAF). The P wave in the 12-lead electrocardiogram (ECG) represents atrial depolarisation. This study aims to utilise the P wave to predict PVI outcomes for PAF. Methods: This single-centre retrospective study aimed to predict PVI outcomes using P wave parameters. It included 211 consecutive patients with first PVI for PAF between 2018 and 2019 and targeted the pulmonary veins (PVs). Procedure success was defined by freedom of ECG-documented AF at 12 months. Digital 12-lead ECGs with 1–50 hertz bandpass filters were monitored before the procedure. Corrected P wave duration (PWDc), P wave amplitude (PWV), P wave dispersion (PWDisp), intra-atrial block (IAB), P wave area (PWA), and P wave terminal force in V1 (PTFV1) were measured before ablation and correlated with the outcomes. Results: Successful PVI occurred in 154 patients (73%). Demographics were similar between both arms. P wave parameters correlated with PVI failure included increased PWDc in all leads except for lead III, aVR, and V3, decreased PWV in lead I (hazard ratio [HR]: 0.7, 95% confidence interval [CI]: 0.53–0.95), lead II (HR: 0.45, 95% CI: 0.22–0.65), aVL (HR: 0.58, 95% CI: 0.22–0.98), and aVF (HR: 0.67, 95% CI: 0.58–0.87), decreased PWA in lead I (HR: 0.55, 95% CI: 0.21–0.76), lead II (HR: 0.48, 95% CI: 0.34–0.87), aVL (HR: 0.65, 95% CI: 0.45–0.96), and aVF (HR: 0.61, 95% CI: 0.32–0.89), and the presence of IAB (HR: 2, 95% CI: 1.4–4.2, p = 0.02). PWDisp and PTFV1 were not correlated with PVI outcome. Conclusions: PWDc, PWA, PWV, and IAB are valuable predictors for PVI outcome for PAF at 12 months.

1 June 2020 in EP Europace
Verified
Journal Article
Open access
PDF file
XLX Li
X Li
BSB Sidhu
B Sidhu
TAT P Almeida
T P Almeida
MEM Ehnesh
M Ehnesh
AMA Mistry
A Mistry
GNG A Ng
G A Ng
Funding Acknowledgements: This work was supported by the NIHR Leicester Biomedical Research Centre. XL was funded by MRC(MR/S037306/1) and BHF (PG/18/33/33780) Background: It remains controversial as to whether rotors detected using phase mapping during persistent atrial fibrillation (persAF) represent main drivers of the underlying mechanism as others found rotors to be located near line of conduction block. Regional electrogram desynchronization (RED) has been suggested as successful targets for persAF ablation, but automatic tools and quantitative measures are lacking. Purpose: We aim to use mean phase coherence (MPC) to automatically identify RED regions during persAF. This method was compared with phase singularity density (PSD) maps. Methods: Patients undergoing left atrial (LA) persAF ablation were enrolled (n = 10). 2048-channel virtual electrograms (VEGMs) were collected from each patient using non-contact mapping (St Jude Velocity System, Ensite Array) for 10 seconds. To remove far field ventricular activities, QRS onset and T wave end locations were detected from ECG lead I (Figure 1A) and only the VEGM segments from T end to QRS onset were included in the analysis. VEGMs were reconstructed using sinusoidal wavelets fitting and the phase of VEGMs determined using Hilbert transform. Phase singularities (PS) were detected using the topological charge method and repetitive PSD maps were generated. RED was defined as the average of MPC of each node against direct neighbouring nodes on the 3D mesh (Figure 1A-B). Linear regression analysis was used to compare the average MPC vs. PSD and vs. the standard deviation of MPC (MPC_SD). Results: A total of 221,184 VEGM segments were analysed with mean duration of 364.2 milliseconds. MPC has shown the ability to quantify the level of synchronisation between VEGMs (Figure 1B). Inverse correlation was found between PSD and average MPC values for all 10 patients (p < 0.0001, Figure 1C). Average MPC and MPC_SD were found to be inversely correlated (p < 0.0001, Figure 1C). Spatially, similar graphic patterns can be found from LA MPC maps and PSD maps for all patients (Figure 1D). Conclusion: We have proposed a method to quantify the level of synchronisation between VEGMs. Phase density mapping showed a considerable agreement with RED regions reflecting regional conducting delays, which supports the previous finding where rotors found at conduction block. Inverse correlation between local average MPC and MPC_SD suggests that conduction delays of the identified regions are not heterogenous, posing directional preferences. Rather than solely looking for rotational activities, this method could identify comprehensive RED regions, which may also explain the conflicting results from different studies targeting rotational activities, where incomplete subsets of RED regions could have been targeted. Atrial RED regions can easily be identified with simultaneously collected electrograms from multi-polar catheters and should be targeted in future persAF studies. Abstract Figure 1

Verified
Journal Article
Open access
PDF file
Ahmed AbdelrazikAhmed Abdelrazik
Ahmed Abdelrazik
MEMahmoud Eldesouky
Mahmoud Eldesouky
IAIbrahim Antoun
Ibrahim Antoun
KTKaung Myat Thu
Kaung Myat Thu
AMAkash Mavilakandy
Akash Mavilakandy
RSRiyaz Somani
Riyaz Somani
Background/Objectives: Accurate localisation of manifest accessory pathways from the 12-lead electrocardiogram remains clinically relevant in Wolff–Parkinson–White syndrome, particularly for pre-procedural planning. Although purpose-built artificial intelligence models have shown promise in ECG interpretation, the reliability of general-purpose multimodal large language models for accessory pathway localisation is unknown. We evaluated two contemporary general-purpose AI systems against an electrophysiology-confirmed reference standard and assessed reproducibility across repeated analyses. Methods: In this retrospective, single-centre proof-of-concept diagnostic accuracy study, 49 consecutive patients with manifest accessory pathways confirmed during electrophysiology study/ablation were included. Anonymised pre-procedural 12-lead ECGs were compiled into a single PDF and analysed by ChatGPT 5 Thinking and Gemini 2.5 Pro using predefined EASY-WPW anatomical categories. Each model was tested in three independent context-reset runs. The primary outcome was repeated-run diagnostic accuracy against the electrophysiology-confirmed pathway location, with confidence intervals calculated using an ECG-clustered approach. Secondary outcomes included majority-vote accuracy, pathway-specific descriptive accuracy, exact output consistency, no-consensus outputs, and “unable to identify” responses. Results: Each model generated 147 repeated outputs from the same 49 ECGs. ChatGPT 5 Thinking correctly localised 28/147 outputs, corresponding to a repeated-run accuracy of 19.0% (ECG-clustered 95% CI 11.5–26.6), while Gemini 2.5 Pro correctly localised 18/147 outputs, corresponding to 12.2% accuracy (95% CI 6.8–17.7). Both models performed below the no-information majority-class baseline of 36.7%. Majority-vote accuracy was 7/49 for ChatGPT 5 Thinking and 2/49 for Gemini 2.5 Pro. Exact output consistency across all three runs was observed in 2/49 ECGs for ChatGPT 5 Thinking and 0/49 ECGs for Gemini 2.5 Pro. Complete no-consensus outputs occurred in 30/49 and 26/49 ECGs, respectively. “Unable to identify” responses were infrequent: 8/147 outputs for ChatGPT 5 Thinking and 2/147 outputs for Gemini 2.5 Pro. Pathway-specific estimates were descriptive only because of class imbalance and small subgroup denominators. Conclusions: General-purpose multimodal large language models demonstrated poor repeated-run accuracy, very low reproducibility, frequent no-consensus outputs, and limited abstention when localising manifest accessory pathways from 12-lead ECGs. These findings do not support their current clinical use for accessory pathway localisation. Future progress is more likely to come from purpose-built, signal-native, or rigorously validated multimodal cardiac AI systems.