17 March 2022 in Journal of the American Chemical Society
16 June 2021 in ACS Central Science
The spread of the COVID-19 pandemic around the world has revealed that it is urgently important to develop rapid and inexpensive assays for antibodies in general and anti-SARS-CoV-2 IgG antibody (anti-SARS-CoV-2 spike glycoprotein S1 antibody) in particular. Herein we report a method to detect the anti-SARS-CoV-2 spike antibody level by using Janus emulsions or Janus particles as biosensors. Janus emulsions are composed of two immiscible hydrocarbon and fluorocarbon oils. The hydrocarbon/water interfaces are functionalized with a secondary antibody of IgG protein and SARS-CoV-2 spike receptor binding domain (RBD), to produce two different Janus emulsions. Mixtures of these Janus droplets enable the detection of the anti-SARS-CoV-2 spike IgG antibody in an agglutination assay caused by the antibody’s binding to both the secondary antibody of IgG antibody and SARS-CoV-2 spike protein RBD. Both qualitative optical images and quantitative fluorescence spectra are able to detect the level of anti-SARS-CoV-2 spike antibody at concentrations as low as 0.2 μg/mL in 2 h. The detection results of clinical human serum samples using this agglutination assay confirm that this method is applicable to clinical samples with good sensitivity and specificity. The reported method is generalizable and can be used to detect other analytes by attaching different biomolecular recognition elements to the surface of the Janus droplets.
30 August 2021 in ACS Central Science
A high-performance chemiresistive gas sensor is described for the detection of hydrogen sulfide (H2S), an acutely toxic and corrosive gas. The chemiresistor operates at room temperature with low power requirements potentially suitable for wearable sensors or for rapid in-field detection of H2S in settings such as pipelines and wastewater treatment plants. Specifically, we report chemiresistors based on single-walled carbon nanotubes (SWCNTs) containing highly oxidizing platinum-polyoxometalate (Pt-POM) selectors. We show that by tuning the vanadium content and thereby the oxidation reactivity of the constituent POMs, an efficient chemiresistive sensor is obtained that is proposed to operate by modulating CNT doping during aerobic H2S oxidation. The sensor shows exceptional sensitivity to trace H2S in air with a ppb-level detection limit, multimonth stability under ambient conditions, and high selectivity for H2S over a wide range of interferants, including thiols, thioethers, and thiophene. Finally, we demonstrate that the robust sensing material can be used to fabricate flexible devices by covalently immobilizing the SWCNT-P4VP network onto a polyimide substrate, further extending the potentially broad utility of the chemiresistors. The strategy presented herein highlights the applicability of concepts in molecular aerobic oxidation catalysis to the development of low-cost analyte detection technologies.
27 March 2024 in Organic Letters
16 February 2023 in Chemistry of Materials