Anna Christrup Madsen

Anna Christrup Madsen

Auto-generated profile, based on publicly available information

Anna Christrup Madsen

Centre for Physical Activity Research, Copenhagen University Hospital

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Experimental Physiology
Verified
Journal Article
Open access
AMAnna Christrup Madsen
Anna Christrup Madsen
RTRie Skovly Thomsen
Rie Skovly Thomsen
SNStine B. Nymand
Stine B. Nymand
JHJacob Peter Hartmann
Jacob Peter Hartmann
IRIben E. Rasmussen
Iben E. Rasmussen
RBRonan M. G. Berg
Ronan M. G. Berg
DLCO/NO, the combined single‐breath measurement of the diffusing capacity to carbon monoxide (DLCO) and nitric oxide (DLNO) measured either during exercise or in the resting supine position may be a useful physiological measure of alveolar–capillary reserve. In the present study, we investigated the between‐day test–retest reliability of DLCO/NO‐based metrics. Twenty healthy volunteers (10 males, 10 females; mean age 25 (SD 2) years) were randomized to repeated DLCO/NO measurements during upright rest followed by either exercise (n = 11) or resting in the supine position (n = 9). The measurements were repeated within 7 days. The smallest real difference (SRD), defined as the 95% confidence limit of the standard error of measurement (SEM), the coefficient of variance (CV), and intraclass correlation coefficients were used to assess test–retest reliability. SRD for DLNO was higher during upright rest (5.4 (95% CI: 4.1, 7.5) mmol/(min kPa)) than during exercise (2.7 (95% CI: 2.0, 3.9) mmol/(min kPa)) and in the supine position (3.0 (95% CI: 2.1, 4.8) mmol/(min kPa)). SRD for DLCOc was similar between conditions. CV values for DLNO were slightly lower than for DLCOc both during exercise (1.5 (95% CI: 1.2, 1.7) vs. 3.8 (95% CI: 3.2, 4.3)%) and in the supine position (2.2 (95% CI: 1.8, 2.5) vs. 4.8 (95% CI: 3.8, 5.4)%). DLNO increased by 12.3 (95% CI: 11.1, 13.4) and DLCOc by 3.3 (95% CI: 2.9, 3.7) mmol/(min kPa) from upright rest to exercise. The DLCO/NO technique provides reliable indices of alveolar–capillary reserve, both during exercise and in the supine position.

2 January 2025 in Scandinavian Journal of Clinical and Laboratory Investigation
Verified
Journal Article
Open access
RTRie Skovly Thomsen
Rie Skovly Thomsen
RRRasmus Syberg Rasmussen
Rasmus Syberg Rasmussen
AMAnna Christrup Madsen
Anna Christrup Madsen
UIUlrik Winning Iepsen
Ulrik Winning Iepsen
RCRegitse Højgaard Christensen
Regitse Højgaard Christensen
RBRonan M. G. Berg
Ronan M. G. Berg
The objective of the current review was to identify whether clinically established lung function metrics of ventilatory and diffusion capacity obtained by standardised methodology are consistent with superior lung function in athletes, and whether this is related to maximal oxygen uptake (VO2max). Three independent reviewers performed a literature search in PubMed, Scopus, and reference screening. Data was extracted and analysed according to a predefined strategy. Studies published between 1970 and 2023 on athletes reporting VO(2)max and at least one of the following lung function metrics: predicted forced expiratory volume in the first second of a forced vital capacity manoeuvre (FEV1%pred); predicted forced vital capacity (FVC%pred); predicted total lung capacity (TLC%pred); predicted pulmonary diffusion capacity for carbon monoxide (DL,CO%pred). Data on population size, age, sex, type of sports, as well as FEV1%pred, FVC%pred, TLC%pred, DL,CO%pred, and VO2max were extracted. Standardised mean, differences, and 95% CI were calculated when data were sufficient. In total, 13 original studies encompassing 193 individuals across various sports disciplines met the inclusion criteria. Pooled FEV1%pred was 111% (108-113%; 13 studies; n=193), FVC%pred 112% (108-116 %; 7 studies; n=118), TLC%pred 106% (103-108 %; 4 studies; n=60), and DL,CO%pred 121% (120-122 %; 2 studies; n=23). None of the studies provided sufficient data to evaluate the relationship between any of the lung function metrics and VO2max. In conclusion, athletes consistently exhibit high ventilatory and diffusing capacity metrics, but it is still unknown whether this is related to VO2max.