Tyler Williams

Tyler Williams

Auto-generated profile, based on publicly available information

Tyler Williams

Brigham Young University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
TWTyler Williams
Tyler Williams
RSRankin Shum
Rankin Shum
DRDevin Rappleye
Devin Rappleye
The electrochemical measurement of concentration in molten chloride salts is a valuable tool for the control of existing and potential industrial processes, recycling of precious materials and energy production. The electrochemical techniques commonly used to measure concentration and each techniques’ associated theory are discussed. Practices which improve measurement accuracy and precision are set forth. Exceptionally accurate and precise measurements published in the literature are evaluated based on their performance in specified concentration ranges. The strengths and weaknesses of the most accurate measurements are briefly explored. Chronopotentiometry (CP) and square wave voltammetry (SWV) are accurate and precise with low concentration measurements. SWV was accurate at low concentrations, even in multi-analyte mixtures. CP was accurate for only single analyte mixtures. Open-circuit potentiometry (OCP) is accurate and precise in single-analyte mixtures but yields large errors in multianalyte mixtures. Cyclic voltammetry (CV), chronoamperometry (CA) and normal pulse voltammetry (NPV) are accurate and precise across all concentration ranges. NPV is exceptionally well suited for measurements in melts with multiple electroactive species.

1 April 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
TWTyler Williams
Tyler Williams
RFRanon Fuller
Ranon Fuller
CVCameron Vann
Cameron Vann
DRDevin Rappleye
Devin Rappleye
Semi-differentiation, or convolution as it is sometimes known, is a mathematical technique commonly used to disentangle overlapping peaks in cyclic or linear sweep voltammograms. However, this technique is often misapplied due to misunderstandings of fractional calculus. Additionally, rigorous treatment and validation of the theory of semi-differential analysis of reversible, soluble-insoluble electrochemical reactions is lacking. Peculiarities of semi-differentiation are explored; theoretical relations for semi-differentiated voltammograms are given; the exponential nature of the theoretical curve is explored; theoretical relations are compared to experimental voltammograms for AgNO3 in 1 M nitric acid at 298 K, NiCl2 in LiCl at 974 K, and LaCl3 in LiCl at 971 K; and the diffusion coefficients calculated from theoretical relations developed in this paper are shown to agree with those calculated using the Berzins-Delahay equation.

2 September 2024 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
RSRankin Shum
Rankin Shum
MCMarah Cragun
Marah Cragun
TWTyler Williams
Tyler Williams
DRDevin Rappleye
Devin Rappleye
Residual water in molten CaCl2 reacts to form different byproducts, such as HCl, which can impact the corrosivity of the salt and efficiency of electrochemical operations, such as electrolytic oxide reduction and electrorefining. The ability to detect and quantify these byproducts electrochemically can provide feedback on the efficacy of vacuum drying and other purification methods, as well as the impact of these byproducts on process operations. An electrochemical signal’s association with the production of H2 is verified and characterized using cyclic voltammetry (CV) and residual gas analysis. CV estimated a 2-electron exchange process associated with H2 production. CV detected trace quantities of an oxidized species containing hydrogen in the salt on the order of 10 ppm. Different salt handling methods were compared for their impact on the hydrogen electrochemical signal. It was found that 30 min of exposure of CaCl2 in a beaker to low-humidity air (<20%) had minimal impact on the H2 production signal.

28 February 2024 in Nuclear Technology
Verified
Journal Article
Closed access
MSMark Schvaneveldt
Mark Schvaneveldt
TWTyler Williams
Tyler Williams
RFRanon Fuller
Ranon Fuller
DRDevin Rappleye
Devin Rappleye

12 June 2024 in Nuclear Technology
Verified
Journal Article
Closed access
TWTyler Williams
Tyler Williams
JTJason Torrie
Jason Torrie
MSMark Schvaneveldt
Mark Schvaneveldt
RFRanon Fuller
Ranon Fuller
GCGreg Chipman
Greg Chipman
DRDevin Rappleye
Devin Rappleye