Brúnó Bánk Balázs

Brúnó Bánk Balázs

Auto-generated profile, based on publicly available information

Brúnó Bánk Balázs

Heart and Vascular Center, Semmelweis University, Budapest, Hungary; Center for Translational Medicine, Semmelweis University, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
PKPéter Márton Kulyassa
Péter Márton Kulyassa
BNBalázs Tamás Németh
Balázs Tamás Németh
IHIstvan Hizoh
Istvan Hizoh
LJLaura Krisztina Jankó
Laura Krisztina Jankó
Zoltán RuzsaZoltán Ruzsa
Zoltán Ruzsa
IÉIstván Ferenc Édes
István Ferenc Édes
Introduction: Percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is a cornerstone of the management of ischemic heart disease. However, in-stent restenosis (ISR) remains a significant clinical challenge, occurring in approximately 5–10% of patients undergoing PCI. This study is designed to compare the efficacy and safety of the primary therapeutic approaches for DES-ISR, specifically drug-coated balloons (DCBs)—paclitaxel-coated balloons (PCBs) and sirolimus-coated balloons (SCBs)—with a new-generation everolimus-eluting stent (EES), contributing to the evolving field of personalized medicine. Methods and Analysis: This prospective, multicentre, randomised, non-inferiority trial aims to enroll 150 patients with DES-ISR, who will be randomised into one of the following: SCB, PCB, or EES. The primary endpoint comparing DCB and EES is late lumen loss (LLL) at 6 months, as measured by quantitative coronary angiography (QCA). Secondary endpoints comparing the three arms include a device-oriented composite endpoint, intraluminal gain, optical coherence tomography (OCT) measured LLL, and correlations between LLL and quantitative flow ratio (QFR). The primary endpoint will be analysed using a non-inferiority design, with a margin set at 0.25 mm, for which the sample size was calculated. Statistical analysis of the primary endpoint will be conducted on an intention-to-treat basis with a one-tailed Mann–Whitney U test with a significance level of 95. Secondary endpoints will be analysed via superiority testing using ANOVA, the Kruskal–Wallis test, logistic regression, or Fisher’s exact test, as appropriate. Ethics and Dissemination: The study protocol has been approved by the Medical Devices Department of the Hungarian National Institute of Pharmacy and Nutrition, ensuring compliance with ethical standards as outlined in the Declaration of Helsinki. All investigators declare no conflicts of interest related to this study. The trial is registered in ClinicalTrials.gov under the ID: NCT04862052.

26 August 2025 in Physica Medica
Verified
Journal Article
Open access
BBBrúnó B Balázs
Brúnó B Balázs
DLDavid Laczkó
David Laczkó
Dorottya GergőDorottya Gergő
Dorottya Gergő
BSBence Szabó
Bence Szabó
GDGabor Z. Duray
Gabor Z. Duray
IÉIstván F. Édes
István F. Édes
Radiation exposure is a well-recognized occupational hazard for catheterization lab personnel. However, the extent of exposure disparities among different staff roles remains unclear. Existing research primarily focuses on primary operators, leaving a gap in understanding radiation risks for ancillary staff. This study aims to evaluate how staff positioning and shielding affect radiation exposure, focusing on disparities between primary operators and ancillary staff during fluoroscopy-guided cardiovascular procedures. After a systematic search across five databases on November 20, 2023, we included studies reporting radiation data for coronary angiographies, structural heart interventions, electrophysiological procedures, or endovascular aorta interventions, with at least one ancillary staff member in prespecified positions. Radiation exposures were compared relative to the primary operator using the Ratio of Means (ROM) during meta-analysis. Risk of Bias was assessed using RoB-2 or ROBINS-E. The review protocol was registered as CRD42023484491. Our meta-analysis, based on 8116 measurements from 3091 procedures across 23 studies, suggests that personnel at the patient's head without shielding may experience higher radiation exposure than primary operators (ROM 1.77, 95% CI: 0.75-4.18), although this difference didn't reach statistical significance. Shielded workers at the head or in secondary/assistant positions received significantly lower radiation than primary operators (ROM 0.26, 95% CI: 0.12-0.57; ROM 0.33, 95% CI: 0.25-0.43). Our results suggest a potential disparity in radiation exposure among catheterization laboratory personnel, with unshielded workers at the patient's head tending to receive the highest levels of exposure. Dedicated shielding solutions and attention to all personnel are imperative.