Shaokai Zheng

Shaokai Zheng

Auto-generated profile, based on publicly available information

Shaokai Zheng

ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
AMAli Mokhtari
Ali Mokhtari
Pascal CorsoPascal Corso
Pascal Corso
BJBernd Jung
Bernd Jung
LFLorenzo Ferrari
Lorenzo Ferrari
SZShaokai Zheng
Shaokai Zheng
Dominik ObristDominik Obrist
Dominik Obrist
Internal carotid artery (ICA) stenoses are a major source of stroke. In addition to traditional cardiovascular risk factors, hemodynamic parameters such as wall shear stress (WSS) are recognized as critical contributors to the progression and rupture of ICA plaques. This study evaluates the ability of 4D flow MRI to predict the velocity and WSS fields in three models of carotid bifurcations representing stenosis ratios of 0% (healthy), 40% (mildly stenosed), and 80% (severely stenosed) in the ICA. The stenosis ratio significantly impacts hemodynamics, increasing peak velocity, WSS, and flow disturbances. Compared to the healthy model, peak velocity rises by 38% in severe stenosis, generating a high-velocity jet and post-stenotic recirculation. Spatially averaged WSS increases by 21.5% in the mildly stenosed model and 99% in the severely stenosed model. Additionally, flow separation and vortex formation intensify as stenosis severity increases. A robust experimental setup with carotid bifurcation phantoms has been developed to eliminate the major sources of uncertainty in the boundary conditions. This enables a detailed quantitative comparison of 4D flow MRI measurements (obtained with a 7T scanner) against results from a CFD simulation. Moreover, the CFD results were validated against results obtained from Direct Numerical Simulations (DNS). Therefore, the CFD data could be used as a reliable high-fidelity reference for the flow within the carotid models. The comparison indicates that 4D flow MRI on a 7T scanner captures the major flow patterns with reasonable accuracy, though quantitative discrepancies increase with the stenosis ratio. Specifically, the peak velocity error rises from 6.1% in healthy arteries to 11.9% in severely stenosed arteries. Similarly, the error in spatially averaged WSS magnitude in the bifurcation region increases from 18% in healthy cases to 38% in severely stenosed cases. These findings underscore the need for validated approaches to accurately analyze complex flow patterns within carotid arteries, especially as even high-quality 4D flow MRI measurements using a 7T scanner with 0.5 mm resolution show diminishing accuracy in such challenging cases.

29 April 2014 in Journal of Fluid Mechanics
Verified
Journal Article
Closed access
PDF file
SZShaokai Zheng
Shaokai Zheng
ELEllen K. Longmire
Ellen K. Longmire
A zero pressure gradient turbulent boundary layer of $\textit {Re}_{\tau }=2500$ was perturbed by a single spanwise array of finite cylinders mounted on the bounding surface and extending through the logarithmic region. The cylinder height was $H/\delta =0.2$ ( $H^{+}=500$ ), where $\delta $ is the boundary layer thickness, with an aspect ratio ( $AR$ ) (height/diameter) of four. Streamwise–spanwise ( $x\text {--}y$ ) planes of the flow were examined by particle image velocimetry (PIV) up to $7\delta $ downstream at a wall-normal location of $z^{+}=300$ for cylinder array spacings ranging from $0.2\delta $ to $0.8\delta $ . Average streamwise velocity fields showed a splitting, then merging pattern of cylinder wakes which occurred further downstream as the cylinder spacing increased. Based on measurements at the furthest downstream location, both the spanwise variation of average streamwise velocity and the Fourier content in the instantaneous fields suggested that the case with $0.6\delta $ cylinder spacing, which matched the dominant spanwise scale in the unperturbed flow, yielded the most persistent downstream flow organization. A flying PIV method was implemented to track specific packet structures over a range $-2<x/\delta <7$ with respect to the cylinder array, corresponding to a time scale of $12.4\delta /U_{\infty }$ . Packets approaching the $0.2\delta $ spacing array first lost their organization but then regained it a distance $2\delta $ downstream, suggesting that a persistent outer layer organization propagated inwards into the log region. For arrays with larger spanwise spacing, approaching packets were generally redirected into the spanwise location midway between cylinders and sometimes enhanced.

13 September 2022 in Bioengineering & Translational Medicine
Verified
Journal Article
Open access
SZShaokai Zheng
Shaokai Zheng
DODominik Obrist
Dominik Obrist
FBFiona Burkhard
Fiona Burkhard
FCFrancesco Clavica
Francesco Clavica
Ureteral stents are indispensable devices in urological practice to maintain and reinstate the drainage of urine in the upper urinary tract. Most ureteral stents feature openings in the stent wall, referred to as side holes (SHs), which are designed to facilitate urine flux in and out of the stent lumen. However, systematic discussions on the role of SH and stent lumen size in regulating flux and shear stress levels are still lacking. In this study, we leveraged both experimental and numerical methods, using microscopic‐Particle Image Velocimetry and Computational Fluid Dynamic models, respectively, to explore the influence of varying SH and lumen diameters. Our results showed that by reducing the SH diameter from to the median wall shear stress levels of the SHs near the ureteropelvic junction and ureterovesical junction increased by over , even though the flux magnitudes through these SH decreased by about . All other SHs were associated with low flux and low shear stress levels. Reducing the stent lumen diameter significantly impeded the luminal flow and the flux through SHs. By means of zero‐dimensional models and scaling relations, we summarized previous findings on the subject and argued that the design of stent inlet/outlet is key in regulating the flow characteristics described above. Finally, we offered some clinically relevant input in terms of choosing the right stent for the right patient.

26 January 2022 in Frontiers in Urology
Verified
Journal Article
Open access
SZShaokai Zheng
Shaokai Zheng
PAPedro Amado
Pedro Amado
BKBernhard Kiss
Bernhard Kiss
FSFabian Stangl
Fabian Stangl
AHAndreas Haeberlin
Andreas Haeberlin
FCFrancesco Clavica
Francesco Clavica
Accurate evaluation of stent encrustation patterns, such as volume distribution, from different patient groups are valuable for clinical management and the development of better stents. This study quantitatively compares stent encrustation patterns from stone and kidney transplant patients. Twenty-seven double-J ureteral stents were collected from patients with stone disease or who underwent kidney transplantation. Encrustations on stent samples were quantified by means of micro−Computed Tomography and semantic segmentation using a Convolutional Neural Network model. Luminal encrustation volume per stent unit was derived to represent encrustation level, which did not differ between patient groups in the first six weeks. However, stone patients showed higher encrustation levels over prolonged indwelling times (p = 0.02). Along the stent shaft body, the stone group showed higher encrustation levels near the ureteropelvic junction compared to the ureterovesical junction (p = 0.013), whereas the transplant group showed no such difference. Possible explanations were discussed regarding vesicoureteral reflux. In both patient groups, stent pigtails were more susceptible to encrustations, and no difference between renal and bladder pigtail was identified. The segmentation method presented in this study is also applicable to other image analysis tasks in urology.

11 October 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
SZShaokai Zheng
Shaokai Zheng
PAPedro Amado
Pedro Amado
DODominik Obrist
Dominik Obrist
FBFiona Burkhard
Fiona Burkhard
FCFrancesco Clavica
Francesco Clavica
In vitro models are indispensable to study the physio-mechanical characteristics of the urinary tract and to evaluate ureteral stent performances. Yet previous models mimicking the urinary bladder have been limited to static or complicated systems. In this study, we designed a simple in vitro bladder model to simulate the dynamics of filling and voiding. The physio-mechanical condition of the model was verified using a pressure-flow test with different bladder outlet obstruction levels, and a reflux test was performed to qualitatively demonstrate the stent associated vesicoureteral reflux (VUR). Finally, the setup was applied with and without the bladder model to perform encrustation tests with artificial urine on commercially available double-J stents, and the volumes of luminal encrustations were quantified using micro-Computed Tomography and image segmentation. Our results suggest that, VUR is an important factor contributing to the dynamics in the upper urinary tract with indwelling stents, especially in patients with higher bladder outlet obstruction levels. The influence of VUR should be properly addressed in future in vitro studies and clinical analyses.

28 May 2021 in Physical Review Fluids
Verified
Journal Article
Closed access
PDF file
SZShaokai Zheng
Shaokai Zheng
PBP. J. K. Bruce
P. J. K. Bruce
CCC. Cuvier
C. Cuvier
JFJ.-M. Foucaut
J.-M. Foucaut
JGJ. M. R. Graham
J. M. R. Graham
JVJohn C. Vassilicos
John C. Vassilicos
In this paper, the turbulence fields generated by a group of modified fractal grids, referred to as the rectangular fractal grids (RFGs), are documented and discussed. The experiments were carried out using hot-wire anemometry in three facilities at Imperial College London and the Laboratory of Fluid Mechanics in Lille, France. Due to the large Reynolds number of the resulting turbulence, several data processing methods for turbulence properties are carefully evaluated. Two spectral models were adopted, respectively, to correct the large and small wave-number ranges of the measured spectrum. After the technical discussion, the measurement results are presented in terms of one-point statistics, length scales, homogeneity, isotropy, and dissipation. The main conclusions are twofold. First, the location of maximum turbulence intensity xpeak is shown to be independent of the inlet Reynolds number but dependent on the ratio between the lengths of the largest grid bars in the transverse and vertical directions. This is crucial to the production of prescribed features of turbulent flows in laboratory. Second, these RFG-generated turbulent flows are shown to be quasihomogeneous in the decay region for x/xpeak>1.5, but the isotropy is poorer than that of the previous studied fractal square grid-generated turbulence. In the beginning of the decay region, a decreasing pattern of the integral length scale Lu and Taylor microscale λ was observed, yet the ratio Lu/λ remained roughly constant along the centerline, so Cε∼Reλ−1, complying with the nonequilibrium scaling relation reported in previous studies for various turbulent flows.