28 October 2021 in Journal of Hand Surgery Global Online
To evaluate the possibility of posterior interosseous nerve (PIN) injury during cortical button deployment and seating associated with bicortical drilling and passage of the cortical button across the distal cortex when repairing a distal biceps rupture in a cadaveric model. Each cadaver was placed in the supine position with the arm extended. A single 4 cm transverse incision was made in the region of the radial tuberosity, 3–4 cm distal to the antecubital fossa flexion crease, and dissected down to the radial tuberosity. A #2 looped nonabsorbable suture was used to baseball stitch the musculotendinous junction to the distal 2.5 cm end of the tendon. A 3.2 mm cannulated drill bit (Arthrex) was used to create a bicortical drill hole in the center of the radial tuberosity aiming 30° ulnar to maximize the distance from the PIN. Fluoroscopy was used to confirm drill placement in the radial tuberosity for all specimens. The posterior aspect of the elbow in all cadavers was subsequently dissected out to directly visualize how far the cannulated drill was from the PIN. Twelve cadavers, average age 57.4 years (range, 27–83 years), were dissected. During deployment, the cortical button contacted the PIN directly in 6 extremities. The cortical button came within 6 mm of the PIN in eleven extremities. In 8 specimens, the cortical button was within 2 mm of the PIN. The PIN was caught directly under the cortical button in one specimen. Placement of a biceps cortical button bicortically when repairing a distal biceps tendon may increase the risk of injury to the PIN during cortical button deployment and seating. Therapeutic IV.
1 December 2022 in Journal of Shoulder and Elbow Arthroplasty
Background: Periprosthetic joint infection (PJI) is a complication of arthroplasty surgery with significant morbidity and mortality. Surgical helmets are a possible source of infection. Pre-existing dust and microorganisms on its surface may be blown into the surgical field by the helmet ventilation system. Methods: Twenty surgical helmets at our institution were assessed through microscopy and polymerase chain reaction testing. Helmets were arranged with agar plates under the front and rear outflow vents. Helmets ran while plates were exchanged at different time points. Bacterial growth was assessed via colony counts and correlated with fan operating time. Gram staining and 16S sequencing were performed to identify bacterial species. Results: The primary microbiological contaminate identified was Burkholderia. There was an inverse relationship between colony formation and fan operating time. The highest number of colonies was found within the first minute of fan operating time. There was a significant decrease in the number of colonies formed from the zero-minute to the three (27 vs 5; P = <.01), four (27 vs 3; P = <.01), and five-minute (27 vs 4; P = <.01) time points for the front outflow plates. A significant difference was also observed between the one-minute and four-minute time points ( P = .046). Conclusion: We observed an inverse relationship between bacterial spread helmet fan operation time, which may correlate with dispersion of pre-existing contaminates. To decrease contamination risk, we recommend that helmets are run for at least 3 min prior to entering the operating room.
1 January 2022 in Journal of Surgical Education
MMMaria Cecilia Madariaga
16 June 2023 in Case Reports in Plastic Surgery and Hand Surgery
This study evaluated what patients consider in choosing a surgeon. A survey was given to 303 patients. Most found their hand surgeon through a medical or family/friend referral (p < .05). Surgeon credentials and accepted insurance were statistically more likely to be rated first (p<.001). We recommend educating referring physicians about our practices.
6 February 2026 in European Spine Journal
24 March 2024 in Journal of the Pediatric Orthopaedic Society of North America
Background: It is estimated that $12.8 billion to $28.6 billion is wasted annually on unnecessary imaging studies and treatment in the United States. This is especially important to the pediatric population, which is unable to make decisions for themselves and vulnerable to radiation exposure. We hypothesized that a significant number of unnecessary radiographs are performed in the pediatric emergency department, leading to excessive time, cost, and radiation exposure to pediatric patients. Methods: We retrospectively reviewed 406 patients who were evaluated in a pediatric emergency department (ED) for possible fracture at a single institution during the 2020 calendar year. Records were reviewed for demographics, history and physical exams, as well as the sequential order that radiographs were performed. All radiographs were evaluated by the senior author to determine if they resulted in a change in management. All data was recorded and analyzed by the senior author and our statistician using Student’s t-test. Results: 406 patient encounters were included. 2807 radiographs were deemed unnecessary, with an average of 6.9 radiographs per patient. $454,734 were spent on radiographs that ultimately did not change management. A total of 216 hours and 43 minutes were spent in the x-ray suite alone, for an average of 32 minutes per patient. The estimated amount of radiation exposure that did not change management was potentially as high as 69 millirem per patient. Conclusions: There is an excessive amount of monetary waste, radiation exposure, and encounter time spent in pediatric orthopedic patients in the ED. There are several potential strategies to alleviate this problem, which we hope can be taken into consideration to help address this widespread healthcare issue.