1 January 2000 in Journal of Electrocardiology
29 April 2016 in Physical Review E
RORamon Martinez Orellana
+4
This paper addresses the challenge of extracting meaningful information from measured bioelectric signals generated by complex, large scale physiological systems such as the brain or the heart. We focus on a combination of the well-known Laplacian eigenmaps machine learning approach with dynamical systems ideas to analyze emergent dynamic behaviors. The method reconstructs the abstract dynamical system phase-space geometry of the embedded measurements and tracks changes in physiological conditions or activities through changes in that geometry. It is geared to extract information from the joint behavior of time traces obtained from large sensor arrays, such as those used in multiple-electrode ECG and EEG, and explore the geometrical structure of the low dimensional embedding of moving time windows of those joint snapshots. Our main contribution is a method for mapping vectors from the phase space to the data domain. We present cases to evaluate the methods, including a synthetic example using the chaotic Lorenz system, several sets of cardiac measurements from both canine and human hearts, and measurements from a human brain.
14 February 2012 in Physiological Research
Although cycle length (CL) constitutes a fundamental descriptor of any arrhythmia, there is not larger study describing mean CL in electrophysiologically confirmed cavo-tricuspid isthmus (CTI)-dependent atrial flutter (AFL). We analyzed retrospectively digital recordings of 121 patients (98 men; age 64±11 years) referred for radiofrequency ablation of persistent CTI-dependent AFL. Median of mean AFL CL was 240 ms (interquartile range (IQR) of 222-258 ms, overall range of 178-399 ms). The distribution of CL was not normal (Shapiro Wilk test, p<0.001). Both counterclockwise and clockwise (14.9 % of all cases) AFLs were comparable in their CL; 240 (IQR 222-258) ms vs. 234 (217-253) ms, respectively. AFL CL<200 ms and AFL CL<190 ms was noticed in 5 (4.1 %) and 3 cases (2.5 %), respectively. In multivariate regression analysis, age (increase by 6±3 ms per decade of age, p=0.036), treatment with specific antiarrhythmic drugs (increase by 11±6 ms, p=0.052) and the history of cardiac surgery (increase by 26±9 ms, p=0.004) were independently associated with AFL CL. In conclusions, the distribution of AFL CL is not normal. The prevalence of AFL with short CL is low. Short CL<200 ms does not rule out the CTI-dependent AFL, especially in young and otherwise healthy patients.
1 June 2006 in Journal of Cardiovascular Electrophysiology
18 January 2007 in Pacing and Clinical Electrophysiology