20 June 2023 in IEEE Transactions on Smart Grid
When multiple virtual synchronous generators (VSG)s operate in parallel in an islanded microgrid, the sudden load power change could lead to significant transient circulating (and oscillating) power. In this paper, the transient circulating power is first analyzed with the two-VSGs small signal model. On this basis, the paper defines parameter design principles that theoretically eliminate all transient circulating power. Due to the line impedances uncertainty in practice, the ideal parameter design is not always available. Then, to suppress the remaining transient circulating power, an enhanced VSG (EVSG) control strategy is further proposed, by deriving and revising a two-VSGs transfer function from load disturbance to power angles difference. The proposed parameter design principles and the EVSG can be applied sequentially, so that the transient circulating power can be systematically suppressed without the side-effects as in existing methods. An experimental platform with 3 VSGs is established. The parameter design principles and the EVSG are thoroughly validated by experimental results. This is also the first time the 3-VSGs experimental results are reported, while all the existing literature has 2-VSGs data. It confirms that the two-VSGs analytical results can be extended to systems with more VSGs.
19 June 2024 in IEEE Transactions on Power Electronics
Grid-forming inverters (GFI) are used to retain the grid inertia and frequency stability with increasing inverter-based sources in the grid. However, as GFI is essentially a fundamental frequency voltage source, grid voltage distortion would induce significant grid current harmonics. In this article, the limitations of the existing types of GFI harmonic current suppression methods are analyzed from a perspective of the equivalent circuit model at harmonic frequencies. Based on this perspective, an intuitive fundamental and harmonic frequencies decoupled control (FHDC) scheme is proposed. At the fundamental frequency, FHDC tracks the voltage command from the GFI power control loop. At harmonic frequencies, the FHDC eliminates the grid-side current harmonics, by canceling out the capacitor current harmonics and eliminating the harmonics otherwise introduced into the inverter-side current command. Compared with existing methods, FHDC is more effective, and also adaptive to wide ranges of grid impedances; meanwhile, it needs no additional sensors and hardware, making it applicable to existing GFI hardware. Finally, in the experiment, the proposed FHDC is not only compared with the conventional GFI, the existing GFI harmonic suppression methods are also implemented in lab test to comparatively verify the superiority of the FHDC.
6 March 2025 in International Journal of Electrical Power & Energy Systems