XiaoBin Peng

XiaoBin Peng

Auto-generated profile, based on publicly available information

XiaoBin Peng

School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing 100191, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017
Verified
Conference Paper
Closed access
LCLi Cheng
Li Cheng
XPXiaobin Peng
Xiaobin Peng
Hui ZhangHui Zhang
Hui Zhang
CWChao Wang
Chao Wang
SFShangchun Fan
Shangchun Fan
SCShaoqing Cao
Shaoqing Cao
We demonstrate a flexible wearable optical fiber strain sensor using side-polished fiber Bragg grating (FBG) with a D-shaped polished zone of ~54 μm depth and ~15 mm length. The opto-mechanical response of the sensor embedded in a biocompatible polydimethylsiloxane elastomer is firstly investigated through various subtle wrist pulse tests. In comparison to a bare FBG, the developed sensor exhibits about two times of magnitude larger in time domain due to the more sensitive light-strain interaction with fiber gratings. Then along with the sound wave profiles of original audios, the extracted throat vibration signals validate the great potential of the sensor for wearable human speech detection.

27 September 2018 in OSA Continuum
Verified
Journal Article
Open access
PDF file
CLCheng Li
Cheng Li
XPXiaoBin Peng
XiaoBin Peng
JLJian Liu
Jian Liu
We demonstrate here a miniature broadband (up to ~12.8 MHz) fiber-tip photoacoustic probe with ~68.32-μm thick MoS2-polydimethylsiloxane (PDMS) composite coating for ultrasound velocity adjustment by the regressive dependence on the temperature and density of saline solution. The composite was applied to the tip of a double-clad fiber with an outer diameter of 125 μm using drop casting. Under a 5-ns pulsed laser excitation, the developed probe sensitivities to temperature and density in the range of 20-50 °C and 0.99-1.10 g/cm3 were investigated in terms of the change in velocity and attenuation of ultrasonic wave transmitting in the saline solution. An excellent goodness of fit (R2>0.99) and significance of the binary linear regression (F>>F0.01) were achieved with the corresponding mean relative errors of 0.38% and 0.12% for measured temperatures and densities, along with a tunable range of 1478.51 to 1679.13 m/s. The proposed technique could therefore be extended for in situ matching ultrasound velocity of coupling liquid at the transducer-tissue boundary in optoacoustic imaging.