Robert John Jacobs

Robert John Jacobs

Auto-generated profile, based on publicly available information

Robert John Jacobs

School of Optometry and Vision Science, University of Auckland, Auckland, New Zealand

Research Focus & Metrics

Academic Career Length

51Years (1976-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2015 in New England Journal of Medicine
Verified
Journal Article
Closed access
PDF file
CMChristopher McKinlay
Christopher McKinlay
JAJane M. Alsweiler
Jane M. Alsweiler
JAJudith M. Ansell
Judith M. Ansell
NANicola S. Anstice
Nicola S. Anstice
JCJ. Geoffrey Chase
J. Geoffrey Chase
JHJane Elizabeth Harding
Jane Elizabeth Harding
Neonatal hypoglycemia is common and can cause neurologic impairment, but evidence supporting thresholds for intervention is limited. We performed a prospective cohort study involving 528 neonates with a gestational age of at least 35 weeks who were considered to be at risk for hypoglycemia; all were treated to maintain a blood glucose concentration of at least 47 mg per deciliter (2.6 mmol per liter). We intermittently measured blood glucose for up to 7 days. We continuously monitored interstitial glucose concentrations, which were masked to clinical staff. Assessment at 2 years included Bayley Scales of Infant Development III and tests of executive and visual function. Of 614 children, 528 were eligible, and 404 (77% of eligible children) were assessed; 216 children (53%) had neonatal hypoglycemia (blood glucose concentration, <47 mg per deciliter). Hypoglycemia, when treated to maintain a blood glucose concentration of at least 47 mg per deciliter, was not associated with an increased risk of the primary outcomes of neurosensory impairment (risk ratio, 0.95; 95% confidence interval [CI], 0.75 to 1.20; P=0.67) and processing difficulty, defined as an executive-function score or motion coherence threshold that was more than 1.5 SD from the mean (risk ratio, 0.92; 95% CI, 0.56 to 1.51; P=0.74). Risks were not increased among children with unrecognized hypoglycemia (a low interstitial glucose concentration only). The lowest blood glucose concentration, number of hypoglycemic episodes and events, and negative interstitial increment (area above the interstitial glucose concentration curve and below 47 mg per deciliter) also did not predict the outcome. In this cohort, neonatal hypoglycemia was not associated with an adverse neurologic outcome when treatment was provided to maintain a blood glucose concentration of at least 47 mg per deciliter. (Funded by the Eunice Kennedy Shriver National Institute of Child Health and Human Development and others.)

23 September 2005 in BMJ
Verified
Journal Article
Closed access
PDF file
ACA John Campbell
A John Campbell
MRM Clare Robertson
M Clare Robertson
SGSteven J La Grow
Steven J La Grow
NKNgaire M Kerse
Ngaire M Kerse
GSGordon F Sanderson
Gordon F Sanderson
LHLeigh A Hale
Leigh A Hale
Abstract Objectives To assess the efficacy and cost effectiveness of a home safety programme and a home exercise programme to reduce falls and injuries in older people with low vision. Design Randomised controlled trial. Setting Dunedin and Auckland, New Zealand. Participants 391 women and men aged ≥(1) 75 with visual acuity of 6/24 or worse who were living in the community; 92% (361 of 391) completed one year of follow-up. Interventions Participants received a home safety assessment and modification programme delivered by an occupational therapist (n = 100), an exercise programme prescribed at home by a physiotherapist plus vitamin D supplementation (n = 97), both interventions (n = 98), or social visits (n = 96). Main outcome measures Numbers of falls and injuries resulting from falls, costs of implementing the home safety programme. Results Fewer falls occurred in the group randomised to the home safety programme but not in the exercise programme (incidence rate ratios 0.59 (95% confidence interval 0.42 to 0.83) and 1.15 (0.82 to 1.61), respectively). However, within the exercise programme, stricter adherence was associated with fewer falls (P = 0.001). A conservative analysis showed neither intervention was effective in reducing injuries from falls. Delivering the home safety programme cost $NZ650 (£234, 344 euros, $US432) (at 2004 prices) per fall prevented. Conclusion The home safety programme reduced falls and was more cost effective than an exercise programme in this group of elderly people with poor vision. The Otago exercise programme with vitamin D supplementation was not effective in reducing falls or injuries in this group, possibly due to low levels of adherence. Trial registration number ISRCTN15342873.

1 January 1979 in Vision Research
Verified
Journal Article
Closed access
RJR.J. Jacobs
R.J. Jacobs

19 June 2013 in BMJ Open
Verified
Journal Article
Open access
PDF file
JBJoanna M. Black
Joanna M. Black
RJR J Jacobs
R J Jacobs
GPG Phillips
G Phillips
LCL Chen
L Chen
ETE Tan
E Tan
Benjamin ThompsonBenjamin Thompson
Benjamin Thompson
Objectives Visual acuity is a common measurement in general practice, and the advent of new technology such as tablet computers offers a change in the way in which these tests are delivered. The aim of this study was to assess whether measurements of distance visual acuity using LogMAR letter charts displayed on an iPad tablet computer were in agreement with standard clinical tests of visual acuity in adults with normal vision. Design Blinded, diagnostic test study. Setting Single centre (University) in Auckland, New Zealand. Participants University staff and students (n=85). Participants were required to have visual acuity better than 6/60 and wear habitual refractive correction during testing. Participants were excluded if there was any history of ocular pathology. Primary and secondary outcome measures Visual acuity measured under a number of conditions. Results The iPad tablet with its glossy screen was highly susceptible to glare resulting in acuity measurements that were significantly poorer (approximately 2 LogMAR lines) than those made using an ETDRS chart and a standard computerised testing system (n=56). However, fitting the iPad with an antiglare screen and positioning the device away from sources creating reflected (veiling) glare resulted in acuity measurements that were equivalent those made using gold standard charts (n=29). Conclusions Tablet computers are an attractive option for visual acuity measurement due to portability, the ability to randomise letters, automated scoring of acuity and the ability to select from a range of charts. However, these devices are only suitable for use in situations where sources of glare can be eliminated.

1 July 1994 in Journal of the Illuminating Engineering Society
Verified
Journal Article
Closed access
SBS.M. Berman
S.M. Berman
MBM.A. Bullimore
M.A. Bullimore
RJR.J. Jacobs
R.J. Jacobs
IBI.L. Bailey
I.L. Bailey
NGN. Gandhi
N. Gandhi
(1994). An Objective Measure of Discomfort Glare. Journal of the Illuminating Engineering Society: Vol. 23, No. 2, pp. 40-49.

1 January 1979 in Vision Research
Verified
Journal Article
Closed access
RHR.F. Hess
R.F. Hess
RJR.J. Jacobs
R.J. Jacobs