Kevin Little

Kevin Little

Auto-generated profile, based on publicly available information

Kevin Little

Department of Radiology The Ohio State University Columbus Ohio USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Journal of the American College of Radiology
Verified
Journal Article
Closed access
KLKevin J. Little
Kevin J. Little
IRIngrid Reiser
Ingrid Reiser
LLLili Liu
Lili Liu
TKTiffany Kinsey
Tiffany Kinsey
ASAdrian A. Sánchez
Adrian A. Sánchez
ZLZheng Feng Lu
Zheng Feng Lu

7 April 2007 in Chemistry of Materials
Verified
Journal Article
Closed access
HZHuajun Zhou
Huajun Zhou
KSKonstantia C. Strates
Konstantia C. Strates
MMMiguel Á. Muñoz
Miguel Á. Muñoz
KLKevin J. Little
Kevin J. Little
DPDaniel M. Pajerowski
Daniel M. Pajerowski
ALAbdessadek Lachgar
Abdessadek Lachgar

30 December 2008 in Physical Review D
Verified
Journal Article
Closed access
KKKen Kiers
Ken Kiers
KLKevin Little
Kevin Little
ADAlakabha Datta
Alakabha Datta
DLDavid London
David London
MNMakiko Nagashima
Makiko Nagashima
ASAlejandro Szynkman
Alejandro Szynkman
We consider CP-violating effects in tau->K pi pi nu_tau, assuming that a charged Higgs boson provides a new amplitude that can interfere with the usual Standard Model amplitude. We consider four CP-odd observables -- the regular rate asymmetry, two modified rate asymmetries and a triple-product asymmetry. The regular rate asymmetry is expected to be small because it requires the interference of the new physics amplitude with the standard model amplitude containing the hadronic scalar form factor. The other CP asymmetries may be more promising in terms of their new physics reach. Numerical estimates indicate that the maximum obtainable values for the modified and triple-product asymmetries are on the order of a percent.Comment: 23 pages, 3 figure

15 October 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BEBarbaros S. Erdal
Barbaros S. Erdal
MDMutlu Demirer
Mutlu Demirer
KLKevin J. Little
Kevin J. Little
CAChiemezie C. Amadi
Chiemezie C. Amadi
GIGehan F. M. Ibrahim
Gehan F. M. Ibrahim
RWRichard D. White
Richard D. White
Consistency and duplicability in Computed Tomography (CT) output is essential to quantitative imaging for lung cancer detection and monitoring. This study of CT-detected lung nodules investigated the reproducibility of volume-, density-, and texture-based features (outcome variables) over routine ranges of radiation dose, reconstruction kernel, and slice thickness. CT raw data of 23 nodules were reconstructed using 320 acquisition/reconstruction conditions (combinations of 4 doses, 10 kernels, and 8 thicknesses). Scans at 12.5%, 25%, and 50% of protocol dose were simulated; reduced-dose and full-dose data were reconstructed using conventional filtered back-projection and iterative-reconstruction kernels at a range of thicknesses (0.6–5.0 mm). Full-dose/B50f kernel reconstructions underwent expert segmentation for reference Region-Of-Interest (ROI) and nodule volume per thickness; each ROI was applied to 40 corresponding images (combinations of 4 doses and 10 kernels). Typical texture analysis metrics (including 5 histogram features, 13 Gray Level Co-occurrence Matrix, 5 Run Length Matrix, 2 Neighboring Gray-Level Dependence Matrix, and 3 Neighborhood Gray-Tone Difference Matrix) were computed per ROI. Reconstruction conditions resulting in no significant change in volume, density, or texture metrics were identified as “compatible pairs” for a given outcome variable. Our results indicate that as thickness increases, volumetric reproducibility decreases, while reproducibility of histogram- and texture-based features across different acquisition and reconstruction parameters improves. To achieve concomitant reproducibility of volumetric and radiomic results across studies, balanced standardization of the imaging acquisition parameters is required.

1 August 2023 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
QYQian Yu
Qian Yu
MPMikin Patel
Mikin Patel
DKDaniel Kwak
Daniel Kwak
EUEthan Ungchusri
Ethan Ungchusri
YWYating Wang
Yating Wang
OAOsman Ahmed
Osman Ahmed

30 March 2023 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
KLKevin Little
Kevin Little
IRIngrid Reiser
Ingrid Reiser
BABruce Apgar
Bruce Apgar
PDPoonam Dalal
Poonam Dalal
JDJaydev Dave
Jaydev Dave
JZJie Zhang
Jie Zhang
Reject rate analysis is considered an integral part of a diagnostic radiography quality control (QC) program. A rejected image is a patient radiograph that was not presented to a radiologist for diagnosis and that contributes unnecessary radiation dose to the patient. Reject rates that are either too high or too low may suggest systemic department shortcomings in QC mechanisms. Due to the lack of standardization, reject data often cannot be easily compared between radiography systems from different vendors. The purpose of this report is to provide guidance to help standardize data elements that are required for comprehensive reject analysis and to propose data reporting and workflows to enable an effective and comprehensive reject rate monitoring program. Essential data elements, a proposed schema for classifying reject reasons, and workflow implementation options are recommended in this task group report.