Krystian A. Kozek

Krystian A. Kozek

Auto-generated profile, based on publicly available information

Krystian A. Kozek

Vanderbilt Center for Arrhythmia Research and Therapeutics, Division of Clinical Pharmacology (R.U., K.K., L.R.V., D.W.M., A.S., Y.W., L.C., M.C.L., A.M.G., B.C.K., D.M.R.), Department of Medicine, Vanderbilt University Medical Center, Nashville, TN

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2019 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
JTJulie B. Trads
Julie B. Trads
KHKatharina Hüll
Katharina Hüll
BMBryan S. Matsuura
Bryan S. Matsuura
LLLaura Laprell
Laura Laprell
TFTimm Fehrentz
Timm Fehrentz
DTDirk Trauner
Dirk Trauner

15 June 2012 in ACS Nano
Verified
Journal Article
Closed access
PKPeter J. Krommenhoek
Peter J. Krommenhoek
JWJunwei Wang
Junwei Wang
NHNathaniel Hentz
Nathaniel Hentz
AJAaron C. Johnston-Peck
Aaron C. Johnston-Peck
KKKrystian A. Kozek
Krystian A. Kozek
JTJoseph B. Tracy
Joseph B. Tracy

11 August 2011 in Langmuir
Verified
Journal Article
Closed access
KRKristen E. Roskov
Kristen E. Roskov
KKKrystian A. Kozek
Krystian A. Kozek
WWWei-Chen Wu
Wei-Chen Wu
RCRaghav K. Chhetri
Raghav K. Chhetri
AOAmy L. Oldenburg
Amy L. Oldenburg
JTJoseph B. Tracy
Joseph B. Tracy

10 October 2013 in Chemistry of Materials
Verified
Journal Article
Closed access
KKKrystian A. Kozek
Krystian A. Kozek
KKKlaudia M. Kozek
Klaudia M. Kozek
WWWei-Chen Wu
Wei-Chen Wu
SMSumeet R. Mishra
Sumeet R. Mishra
JTJoseph B. Tracy
Joseph B. Tracy

3 December 2024 in Circulation
Verified
Journal Article
Closed access
MOMatthew J. O’nEill
Matthew J. O’nEill
CNChai-Ann Ng
Chai-Ann Ng
TATakanori Aizawa
Takanori Aizawa
LSLuca Sala
Luca Sala
SBSahej Bains
Sahej Bains
BKBrett M. Kroncke
Brett M. Kroncke
BACKGROUND: Long QT syndrome is a lethal arrhythmia syndrome, frequently caused by rare loss-of-function variants in the potassium channel encoded by KCNH2 . Variant classification is difficult, often because of lack of functional data. Moreover, variant-based risk stratification is also complicated by heterogenous clinical data and incomplete penetrance. Here we sought to test whether variant-specific information, primarily from high-throughput functional assays, could improve both classification and cardiac event risk stratification in a large, harmonized cohort of KCNH2 missense variant heterozygotes. METHODS: We quantified cell-surface trafficking of 18 796 variants in KCNH2 using a multiplexed assay of variant effect (MAVE). We recorded KCNH2 current density for 533 variants by automated patch clamping. We calibrated the strength of evidence of MAVE data according to ClinGen guidelines. We deeply phenotyped 1458 patients with KCNH2 missense variants, including QTc, cardiac event history, and mortality. We correlated variant functional data and Bayesian long QT syndrome penetrance estimates with cohort phenotypes and assessed hazard ratios for cardiac events. RESULTS: Variant MAVE trafficking scores and automated patch clamping peak tail currents were highly correlated (Spearman rank-order ρ=0.69; n=433). The MAVE data were found to provide up to pathogenic very strong evidence for severe loss-of-function variants. In the cohort, both functional assays and Bayesian long QT syndrome penetrance estimates were significantly predictive of cardiac events when independently modeled with patient sex and corrected QT interval (QTc); however, MAVE data became nonsignificant when peak tail current and penetrance estimates were also available. The area under the receiver operator characteristic curve for 20-year event outcomes based on patient-specific sex and QTc (area under the curve, 0.80 [0.76–0.83]) was improved with prospectively available penetrance scores conditioned on MAVE (area under the curve, 0.86 [0.83–0.89]) or attainable automated patch clamping peak tail current data (area under the curve, 0.84 [0.81–0.88]). CONCLUSIONS: High-throughput KCNH2 variant MAVE data meaningfully contribute to variant classification at scale, whereas long QT syndrome penetrance estimates and automated patch clamping peak tail current measurements meaningfully contribute to risk stratification of cardiac events in patients with heterozygous KCNH2 missense variants.

12 April 2011 in Physical Review E
Verified
Journal Article
Closed access
PDF file
RCRaghav K. Chhetri
Raghav K. Chhetri
KKKrystian A. Kozek
Krystian A. Kozek
AJAaron C. Johnston-Peck
Aaron C. Johnston-Peck
JTJoseph B. Tracy
Joseph B. Tracy
AOAmy L. Oldenburg
Amy L. Oldenburg
We demonstrate depth-resolved viscosity measurements within a single object using polarized optical scattering from ensembles of freely tumbling plasmon resonant gold nanorods (GNRs) monitored with polarization-sensitive optical coherence tomography. The rotational diffusion coefficient of the GNRs is shown to correlate with viscosity in molecular fluids according to the Stokes-Einstein relation. The plasmon resonant and highly anisotropic properties of GNRs are favorable for microrheological studies of nanoscale properties.