Guillaume Gatineau

Guillaume Gatineau

Auto-generated profile, based on publicly available information

Guillaume Gatineau

Centre of Bone Diseases, Rheumatology Unit, Bone and Joint Department, Lausanne University Hospital, University of Lausanne and Medimaps group SA , Lausanne, VD

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2024 in Journal of Cachexia, Sarcopenia and Muscle
Verified
Journal Article
Open access
CVColin Vendrami
Colin Vendrami
ESEnisa Shevroja
Enisa Shevroja
ERElena Gonzalez Rodriguez
Elena Gonzalez Rodriguez
GGGuillaume Gatineau
Guillaume Gatineau
JEJolanda Elmers
Jolanda Elmers
DHDidier Hans
Didier Hans
Half of osteoporotic fractures occur in patients with normal/osteopenic bone density or at intermediate or low estimated risk. Muscle measures have been shown to contribute to fracture risk independently of bone mineral density. The objectives were to review the measurements of muscle health (muscle mass/quantity/quality, strength and function) and their association with incident fragility fractures and to summarize their use in clinical practice. This scoping review follows the PRISMA‐ScR guidelines for reporting. Our search strategy covered the three overreaching concepts of ‘fragility fractures’, ‘muscle health assessment’ and ‘risk’. We retrieved 14 745 references from Medline Ovid SP, EMBASE, Web of Science Core Collection and Google Scholar. We included original and prospective studies on community‐dwelling adults aged over 50 years that analysed an association between at least one muscle parameter and incident fragility fractures. We systematically extracted 17 items from each study, including methodology, general characteristics and results. Data were summarized in tables and graphically presented in adjusted forest plots. Sixty‐seven articles fulfilled the inclusion criteria. In total, we studied 60 muscle parameters or indexes and 322 fracture risk ratios over 2.8 million person‐years (MPY). The median (interquartile range) sample size was 1642 (921–5756), age 69.2 (63.5–73.6) years, follow‐up 10.0 (4.4–12.0) years and number of incident fragility fractures 166 (88–277). A lower muscle mass was positively/not/negatively associated with incident fragility fracture in 28 (2.0), 64 (2.5) and 10 (0.2 MPY) analyses. A lower muscle strength was positively/not/negatively associated with fractures in 53 (1.3), 57 (1.7 MPY) and 0 analyses. A lower muscle function was positively/not/negatively associated in 63 (1.9), 45 (1.0 MPY) and 0 analyses. An in‐depth analysis shows how each single muscle parameter was associated with each fragility fractures subtype. This review summarizes markers of muscle health and their association with fragility fractures. Measures of muscle strength and function appeared to perform better for fracture risk prediction. Of these, hand grip strength and gait speed are likely to be the most practical measures for inclusion in clinical practice, as in the evaluation of sarcopenia or in further fracture risk assessment scores. Measures of muscle mass did not appear to predict fragility fractures and might benefit from further research, on D3‐creatine dilution test, lean mass indexes and artificial intelligence methods.

20 August 2024 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
GGGuillaume Gatineau
Guillaume Gatineau
ESEnisa Shevroja
Enisa Shevroja
CVColin Vendrami
Colin Vendrami
ERElena Gonzalez Rodriguez
Elena Gonzalez Rodriguez
WLWilliam D Leslie
William D Leslie
DHDidier Hans
Didier Hans
An abundance of medical data and enhanced computational power have led to a surge in artificial intelligence (AI) applications. Published studies involving AI in bone and osteoporosis research have increased exponentially, raising the need for transparent model development and reporting strategies. This review offers a comprehensive overview and systematic quality assessment of AI articles in osteoporosis while highlighting recent advancements. A systematic search in the PubMed database, from December 17, 2020 to February 1, 2023 was conducted to identify AI articles that relate to osteoporosis. The quality assessment of the studies relied on the systematic evaluation of 12 quality items derived from the minimum information about clinical artificial intelligence modeling checklist. The systematic search yielded 97 articles that fell into 5 areas; bone properties assessment (11 articles), osteoporosis classification (26 articles), fracture detection/classification (25 articles), risk prediction (24 articles), and bone segmentation (11 articles). The average quality score for each study area was 8.9 (range: 7–11) for bone properties assessment, 7.8 (range: 5–11) for osteoporosis classification, 8.4 (range: 7–11) for fracture detection, 7.6 (range: 4–11) for risk prediction, and 9.0 (range: 6–11) for bone segmentation. A sixth area, AI-driven clinical decision support, identified the studies from the 5 preceding areas that aimed to improve clinician efficiency, diagnostic accuracy, and patient outcomes through AI-driven models and opportunistic screening by automating or assisting with specific clinical tasks in complex scenarios. The current work highlights disparities in study quality and a lack of standardized reporting practices. Despite these limitations, a wide range of models and examination strategies have shown promising outcomes to aid in the earlier diagnosis and improve clinical decision-making. Through careful consideration of sources of bias in model performance assessment, the field can build confidence in AI-based approaches, ultimately leading to improved clinical workflows and patient outcomes.

4 March 2025 in Osteoporosis International
Verified
Journal Article
Open access
PDF file
GGGuillaume Gatineau
Guillaume Gatineau
KHKaren Hind
Karen Hind
ESEnisa Shevroja
Enisa Shevroja
ERElena Gonzalez Rodriguez
Elena Gonzalez Rodriguez
OLOLIVIER LAMY
OLIVIER LAMY
DHDidier Hans
Didier Hans
Summary This study compared TBS v4.0, which uses DXA-derived tissue thickness corrections, with TBS v3, which adjusts using BMI. TBS v4.0 improved soft tissue adjustments and maintained fracture risk prediction equivalence with TBS v3, enhancing applicability across diverse body compositions/phenotypes. Direct tissue thickness adjustment increases TBS’s utility in osteoporosis assessment and management. Purpose This study aimed to compare trabecular bone score (TBS) version 4.0, which uses direct tissue thickness correction via DXA measurements, with TBS version 3, which adjusts for soft tissues using body mass index (BMI). The objective was to assess the performance of TBS v4.0 compared to v3, for bone health evaluation and fracture risk assessment across diverse body compositions. Methods Data from the OsteoLaus cohort were analyzed. Associations between TBS, BMI, DXA-measured tissue thickness, visceral fat (VFAT), and android fat were examined using regression and correlation analyses. Machine learning, including Random Forest (RF) and SHapley Additive exPlanations (SHAP), explored TBS changes between versions. Five-year fracture risk was assessed using FRAX adjustment, and logistic regression. Results TBS v3 correlated with BMI (r = 0.110, p < 0 .001), VFAT mass (r = − 0.162, p < 0 .001), and soft tissue thickness (r = − 0.165, p < 0.001). TBS v4.0 demonstrated weaker correlations with BMI (r = − 0.057, p > 0.999), VFAT Mass (r = − 0.067, p > 0.779), and soft tissue thickness (r = − 0.114, p = 0.019). Differences between TBS versions were investigated with SHapley Additive exPlanations (SHAP) and explained by BMI, tissue thickness, VFAT, and gynoid fat. Logistic regression and Delong’s test revealed no significant differences in vertebral fracture prediction between the two TBS versions (p = 0.564). FRAX adjustments were highly consistent between versions (r = 0.994, p < 0.001), with no evidence of calibration bias (p = 0.241). Conclusion TBS v4.0 enhances the adjustment for regional soft tissue effects and results suggest comparable vertebral fracture risk prediction to TBS v3. Explainable AI provided insights into the contributions of BMI, tissue thickness, visceral fat, and gynoid fat to the observed changes between TBS versions. Incorporating direct tissue thickness adjustment improves TBS applicability across diverse body sizes and compositions.

10 July 2024 in JBMR Plus
Verified
Journal Article
Open access
PDF file
CVColin Vendrami
Colin Vendrami
GGGuillaume Gatineau
Guillaume Gatineau
ERElena Gonzalez Rodriguez
Elena Gonzalez Rodriguez
OLOLIVIER LAMY
OLIVIER LAMY
DHDidier Hans
Didier Hans
ESEnisa Shevroja
Enisa Shevroja
Body composition (BC) measured by DXA differs between devices. We aimed to compare regional and total BC measurements assessed by the Hologic Horizon A and the GE Lunar iDXA devices; to determine device-specific calibration equations for each BC parameter; and to assess the impact of this standardization procedure on the assessment of sarcopenia, lipedema, obesity, and cardiovascular risk with DXA. A total of 926 postmenopausal women (aged 72.9 ± 6.9 yr, height 160.3 ± 6.6 cm, weight 66.1 ± 12.7 kg) underwent BC assessment on each device within 1 h, following the ISCD guidelines. The included sample was split into 80% train and 20% test datasets stratified by age, height, and weight. Inter-device differences in BC parameters were assessed with Bland–Altman analysis, Pearson or Spearman correlation coefficients, and t-tests or Wilcoxon tests. The equations were developed in the train dataset using backward stepwise multiple linear regressions and were evaluated in the test dataset with the R-squared and mean absolute error. We compared the abovementioned BC-derived health conditions before and after standardization in the test set with respect to relative risk, accuracy, Kappa score, and McNemar tests. Total and regional body masses were similar (p>.05) between devices. BMC was greater for all regions in the Lunar device (p<.05), while fat and lean masses differed among regions. Regression equations showed high performance metrics in both datasets. The BC assessment from Hologic classified 2.13 times more sarcopenic cases (McNemar: p<.001), 1.39 times more lipedema (p<.001), 0.40 times less high cardiovascular risk (p<.001), and similarly classified obesity (p>.05), compared to Lunar. After standardization, the differences disappeared (p>.05), and the classification metrics improved. This study discusses how hardware and software differences impact BC assessments. The provided standardization equations address these issues and improve the agreement between devices. Future studies and disease definitions should consider these differences. DXA is a versatile and accessible imaging technique for the quantification of fat, lean, and bone tissues. We aimed to compare body composition using 2 recent DXA devices in 926 Swiss postmenopausal women who underwent body composition assessment on each device at 1-h intervals. Total body fat, lean, and bone masses differed significantly between devices, with greater fat mass assessed on the Lunar device and greater lean mass on the Hologic device. According to the regional analysis of the arms, legs, and trunk, these trends were inconsistently distributed between the devices. Univariate and multivariate calibration equations were developed in a training dataset with 80% of the participants. These equations accounted for all differences in the DXA measurements, including those in the internal validation dataset based on the remaining 20% of participants. The equations also accounted for up to 2-fold device differences seen in the assessment of sarcopenia, cardiovascular risk, lipedema, and obesity. This study provides insight on how DXA hardware and software affect the final assessment of body composition. We provide calibration equations to standardize measurements and increase agreement between devices. Although external validation is needed, further studies and disease definitions should account for these device differences.

4 June 2025 in Journal of Cachexia, Sarcopenia and Muscle
Verified
Journal Article
Open access
CVColin Vendrami
Colin Vendrami
ERElena Gonzalez Rodriguez
Elena Gonzalez Rodriguez
GGGuillaume Gatineau
Guillaume Gatineau
PVPeter Vollenweider
Peter Vollenweider
Pedro Marques-VidalPedro Marques-Vidal
Pedro Marques-Vidal
ESEnisa Shevroja
Enisa Shevroja
Background: Muscle strength, mass and function have been associated with falls, fractures and mortality, but the results vary between previous studies. We aimed to investigate the predictive ability of muscle strength and mass with 10‐year incident fragility fractures.Methods: This study included 1475 postmenopausal women aged 50–80 years (OsteoLaus cohort, Lausanne, Switzerland). Handgrip strength (HGS) was assessed. With a Jamar dynamometer and lean mass (LM) with dual x‐ray absorptiometers (DXA) every 2.5 years for 10 years. LM, appendicular lean mass (ALM) and their indexes were assessed following the International Society for Clinical Densitometry (ISCD) guidelines. Main outcomes included hip, humerus and forearm low‐trauma fractures from in‐person interviews and vertebral fracture (VF) from lateral DXA screening. Secondary outcomes included falls and death. Baseline values were compared using two‐sided t‐test or Wilcoxon test (p < 0.0029 based on Bonferroni). Multivariate analysis included time to fracture with accelerated failure time (AFT) model and odds ratio (OR) with logistic regression, 95% confidence interval (CI) and C‐Index or AUC.Results: After 10.2 ± 0.4 years of follow‐up, 944 women remained enrolled (age 73.0 ± 6.9 years, BMI 25.7 ± 4.8 kg/m2, ALM 16.8 ± 2.5 kg, HGS 21.2 ± 5.5 kg), of whom 260 fractured (174 VF, 107 non‐VF), 863 fell and 74 died. Participants with an incident fragility fracture had a 1.5‐kg lower HGS at baseline but no significant difference in their ALM, ALM/height2 and ALM/BMI compared to nonfractured participants. In the multivariable models, one SD increase in ALM (+2.58 kg) was associated with a 0.72 (CI:0.61–0.85) and 0.67 (CI:0.55–0.82) shorter time to major osteoporotic fractures (MOF) and VF. While ALM/BMI was associated with a 1.26 (CI:1.01–1.59) and 1.98 (CI:1.21–3.25) longer time to MOF and non‐VF. One SD increase in HGS was associated with a 1.37 (CI:1.03–1.81) longer time to non‐VF only. A careful consideration of body weight and fat mass is needed in the association of lean mass with fractures. Baseline muscle parameters were not different for participant with or without incident fall or death.Conclusions: Lean mass and grip strength appear as independent risk factors for incident MOF, but with limited additional prediction performance. The prediction of fragility fractures differs between the fracture sites. Further studies with larger sample size, other muscle assessment modalities considering weight or fat mass as covariate, and broader ethnicities are needed.

14 May 2026 in eClinicalMedicine
Verified
Journal Article
Open access
GGGuillaume Gatineau
Guillaume Gatineau
MGMichele De Gruttola
Michele De Gruttola
KHKaren Hind
Karen Hind
MDMadeleine Davies
Madeleine Davies
DKDiane Krueger
Diane Krueger
DHDidier Hans
Didier Hans
Artificial Intelligence (AI)-based opportunistic risk stratification solutions can help to counter rising fragility fracture rates. Existing tools estimate bone mineral density (BMD) alone, while the present study incorporates trabecular bone score (TBS), a surrogate of bone microarchitecture, more closely mirroring fracture pathophysiology. We aimed to evaluate the performance of an AI tool that estimates bone fragility directly from standard radiographs to identify individuals at highest risk of fracture. This retrospective, multinational cohort study included 18,858 paired radiographs and lumbar spine dual-energy X-ray absorptiometry (DXA) scans from adult patients (aged at least 20 years) from three clinical sites in Europe and two sites in the United States. Routine clinical radiographs of the spine, abdomen, chest, or pelvis acquired in the anteroposterior or posteroanterior view and including visualisation of the lumbar spine were included. Eligible radiographs had an in-plane spatial resolution of ≤0.2 mm per pixel, independent of vendor, and had a corresponding DXA examination within 6 months, and included at least two lumbar vertebrae (L1–L4). The AI model training used a composite Bone Fragility Index, combining TBS and BMD. Training, internal validation and testing was performed on two European sites (n = 10,692; Italy and Austria); and external validation involved three sites with ethnically diverse populations (n = 7079): Slovakia, US site 1 (Wisconsin) and US site 2 (New York). Model performance for identifying very high bone fragility (characterised by degraded TBS and osteoporosis) prioritised specificity (as per the intended clinical use to prioritise low false-positive rates) and was evaluated with accuracy, sensitivity, specificity, AUC and precision. Between Jan 1, 2010 and Dec 31, 2023, 18,858 paired radiographs and lumbar spine dual-energy X-ray absorptiometry (DXA) scans from 11,138 participants across five international sites were retrospectively aggregated. Internal testing on two European sites demonstrated an accuracy of 0.86 (95% CI: 0.78, 0.92), specificity of 0.93 (0.85, 0.99), and sensitivity of 0.53 (0.41, 0.67). External testing on three sites demonstrated consistently high specificity of 0.88 (0.77, 0.99) in the European cohort, 0.94 (0.91, 0.97) in the American White dataset, and 0.96 (0.81, 0.99) in the American Non-White. External sensitivity ranged from 0.53 (0.41, 0.67) to 0.64 (0.50, 0.88). The proposed approach provides rapid identification of individuals with very high bone fragility from routine radiographs. Its specificity across diverse populations supports clinical use for opportunistic osteoporosis screening in real-world settings. Future work should assess the model’s performance in more sex-balanced cohorts without prior DXA assessment, and evaluate its ability to predict incident fractures. The Swiss National Science Foundation, the Foundation of the Orthopaedic Hospital of the Vaudois University Hospital (Lausanne, Switzerland), and Medimaps Group SA, Switzerland.