Haicheng Yao

Haicheng Yao

Auto-generated profile, based on publicly available information

Haicheng Yao

China Southern Power Grid,Dispatching Centre,Guangzhou,China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2020 in IEEE Access
Verified
Journal Article
Open access
JHJiyu Huang
Jiyu Huang
LGLin Guan
Lin Guan
YSYinsheng Su
Yinsheng Su
HYHaicheng Yao
Haicheng Yao
MGMengxuan Guo
Mengxuan Guo
ZZZhi Zhong
Zhi Zhong
Reliable online transient stability assessment (TSA) is fundamentally required for power system operation security. Compared with time-costly classical digital simulation methods, data-driven deep learning (DL) methods provide a promising technique to build a TSA model. However, general DL models show poor adaptability to the variation of power system topology. In this paper, we propose a new graph-based framework, which is termed as recurrent graph convolutional network based multi-task TSA (RGCN-MT-TSA). Both the graph convolutional network (GCN) and the long short-term memory (LSTM) unit are aggregated to form the recurrent graph convolutional network (RGCN), where the GCN explicitly integrate the bus (node) states with the topological characteristics while the LSTM subsequently captures the temporal features. We also propose a multi-task learning (MTL) scheme, which provides joint training of stability classification (Task-1) as well as critical generator identification (Task-2) in the framework, and accelerate the process with parallel computing. Test results on IEEE 39 Bus system and IEEE 300 Bus system indicate the superiority of the proposed scheme over existing models, as well as its robustness under various scenarios.

16 July 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JHJiyu Huang
Jiyu Huang
LGLin Guan
Lin Guan
YSYinsheng Su
Yinsheng Su
HYHaicheng Yao
Haicheng Yao
MGMengxuan Guo
Mengxuan Guo
ZZZhi Zhong
Zhi Zhong
Data-driven transient stability assessment (TSA) models are usually sensitive to system scale changes and require dynamic information from time-domain simulation (TDS) as inputs. We propose a S ystem-sc A le- F re E T ransient C ontingency S creening (SAFE-TCS) scheme based on only the steady-state measurements. An analytical model is set up to estimate the state variation at fault occurrence ( $t_{0+}$ ) snapshot, which forms multi-graph inputs together with the steady-state information. A novel pooling-ensemble multi-attention graph convolutional network (PE-MAGCN) realizes the spatio-temporal graph embedding, in which an inter-graph convolution link works for the temporal abstraction. Following a pooling-ensemble mechanism, PE-MAGCN derives a fixed-size expressive vector for task-specific networks. This promotes the robustness of the model against system extension. The advantages of SAFE-TCS also benefit from the coordination of various training tricks, including channel attention, category-balanced sampling and joint-decoupling learning, etc. Test results on IEEE 39 Bus system and IEEE 300 Bus system indicate the superiority of the proposed scheme over existing models and its adaptability under various scenarios.

1 January 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
DJDuan Jinchang
Duan Jinchang
LZLi Zhiyong
Li Zhiyong
YHYao Haicheng
Yao Haicheng
LBLi Bao
Li Bao
ZQZhou Qiang
Zhou Qiang
Short-term power load forecasting is an important link in power grid dispatching, which has an important impact on unit combination, economic dispatching, optimal power flow, etc. As meteorological factors have great influence on load, the influence of meteorological factors should be considered reasonably in short-term load forecasting. The accuracy of short-term electric charge prediction results can help senior personnel of the power system to make accurate and feasible power operation methods. In order to ensure the safe and stable operation of power grid in various special periods and to ensure the economic benefits of related power enterprises to the greatest extent, it is imperative to establish a highly accurate prediction model. The accuracy of power load forecasting will directly affect the position of each power enterprise in the market. Based on the function of time series embedding, this paper analyzes the rule of cumulative effect on load. The correlation between temperature and load is greatly improved after considering the cumulative effect to deal with temperature correction.

28 July 2023
Verified
Conference Paper
Closed access
YSYinsheng Su
Yinsheng Su
STSijia Tu
Sijia Tu
GXGuanghu Xu
Guanghu Xu
LZLigang Zhao
Ligang Zhao
HYHaicheng Yao
Haicheng Yao
BLBao Li
Bao Li
In transmission lines, in order to ensure reliable power supply and safe operation of the system, single-phase switch reclosure is widely used in morden power systems due to its simple logic and mature technology. For long-term or permanent faults, the current flowing through the switch before and after reclosing cannot suddenly change, resulting in the generation of DC component. The amplitude or dacay time of the DC component being too large may delay the zero crossing time of the current flowing through the switch, leading to the failure of the switch tripping, and ultimately causing serious consequences and incalculable losses. The existing national standards only propose short-circuit current calculation methods that consider DC components, and do not involve the calculation and risk assessment methods for DC components generated by single-phase switch reclosure in transmission lines. This article analyzes the mechanism of the DC component generated by single-phase switch reclosure, proposes a practical engineering algorithm, and put forward a risk assessment method. The study case proves the practicality and convenience of proposed method.