Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester M20 4BX, UK
Auto-generated profile, based on publicly available information
Thomas Hambrock
Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester M20 4BX, UK
This review describes fundamentals of multiparametric MR imaging for prostate cancer and provides an overview of separate MR imaging techniques with their combined merits and limitations for clinical challenges such as detection, localization, local staging, and active surveillance. This review presents the current state of the art regarding multiparametric magnetic resonance (MR) imaging of prostate cancer. Technical requirements and clinical indications for the use of multiparametric MR imaging in detection, localization, characterization, staging, biopsy guidance, and active surveillance of prostate cancer are discussed. Although reported accuracies of the separate and combined multiparametric MR imaging techniques vary for diverse clinical prostate cancer indications, multiparametric MR imaging of the prostate has shown promising results and may be of additional value in prostate cancer localization and local staging. Consensus on which technical approaches (field strengths, sequences, use of an endorectal coil) and combination of multiparametric MR imaging techniques should be used for specific clinical indications remains a challenge. Because guidelines are currently lacking, suggestions for a general minimal protocol for multiparametric MR imaging of the prostate based on the ...
Undetected cancer in repeat transrectal ultrasound guided prostate biopsies in patients with increased prostate specific antigen greater than 4 ng/ml is a considerable concern. We investigated the tumor detection rate of tumor suspicious regions on multimodal 3 Tesla magnetic resonance imaging and subsequent magnetic resonance imaging guided biopsy in 68 men with repeat negative transrectal ultrasound guided prostate biopsies. We compared results to those in a matched transrectal ultrasound guided prostate biopsy population. Also, we determined the clinical significance of detected tumors. A total of 71 consecutive patients with prostate specific antigen greater than 4 ng/ml and 2 or greater negative transrectal ultrasound guided prostate biopsy sessions underwent multimodal 3 Tesla magnetic resonance imaging. In 68 patients this was followed by magnetic resonance imaging guided biopsy directed toward tumor suspicious regions. A matched multisession transrectal ultrasound guided prostate biopsy population from our institutional database was used for comparison. The clinical significance of detected tumors was established using accepted criteria, including prostate specific antigen, Gleason grade, stage and tumor volume. The tumor detection rate of multimodal 3 Tesla magnetic resonance imaging guided biopsy was 59% (40 of 68 cases) using a median of 4 cores. The tumor detection rate was significantly higher than that of transrectal ultrasound guided prostate biopsy in all patient subgroups (p <0.01) except in those with prostate specific antigen greater than 20 ng/ml, prostate volume greater than 65 cc and prostate specific antigen density greater than 0.5 ng/ml/cc, in which similar rates were achieved. Of the 40 patients with identified tumors 37 (93%) were considered highly likely to harbor clinically significant disease. Multimodal magnetic resonance imaging is an effective technique to localize prostate cancer. Magnetic resonance imaging guided biopsy of tumor suspicious regions is an accurate method to detect clinically significant prostate cancer in men with repeat negative biopsies and increased prostate specific antigen.
Purpose: To prospectively compare image quality and accuracy of prostate cancer localization and staging with body-array coil (BAC) versus endorectal coil (ERC) T2-weighted magnetic resonance (MR) imaging at 3 T, with histopathologic findings as the reference standard. Materials and Methods: After institutional review board approval and written informed consent, 46 men underwent 3-T T2-weighted MR imaging with a BAC (voxel size, 0.43 × 0.43 × 4.00 mm) and an ERC (voxel size, 0.26 × 0.26 × 2.50 mm) before radical prostatectomy. Four radiologists independently evaluated data sets obtained with the BAC and ERC separately. Ten image quality characteristics related to prostate cancer localization and staging were assigned scores. Prostate cancer presence was recorded with a five-point probability scale in each of 14 segments that included the whole prostate. Disease stage was classified as organ-confined or locally advanced with a five-point probability scale. Whole-mount-section histopathologic examination wa...
Use of 3-T multiparametric MR imaging, consisting of T2-weighted imaging, low-b- value (<1000 sec/mm2) diffusion-weighted apparent diffusion coefficient mapping, and dynamic contrast material–enhanced MR imaging, may not improve transition zone cancer detection and localization accuracy compared with those attained with 3-T T2-weighted imaging alone. PurposeTo retrospectively compare transition zone (TZ) cancer detection and localization accuracy of 3-T T2-weighted magnetic resonance (MR) imaging with that of multiparametric (MP) MR imaging, with radical prostatectomy specimens as the reference standard.Materials and MethodsThe informed consent requirement was waived by the institutional review board. Inclusion criteria were radical prostatectomy specimen TZ cancer larger than 0.5 cm3 and 3-T endorectal presurgery MP MR imaging (T2-weighted imaging, diffusion-weighted [DW] imaging apparent diffusion coefficient [ADC] maps [b < 1000 sec/mm2], and dynamic contrast material–enhanced [DCE] MR imaging). From 197 patients with radical prostatectomy specimens, 28 patients with TZ cancer were included. Thirty-five patients without TZ cancer were randomly selected as a control group. Four radiologists randomly scored T2-weighted and DW ADC images, T2-weighted and DCE MR images, and T2-weighted, DW ADC, and DCE MR images. TZ cancer suspicion was rated on a five...