Increasing levels of distributed solar photovoltaic (PV) generation has created significant technical challenges in distribution networks, particularly regarding voltage regulation. Small-scale behind-the-meter battery storage is a key element in effectively overcoming such challenges, while offering financial benefits for customers. In this paper, we propose an optimization-based approach for dispatching power from residential-scale battery storage for grid support and customer savings, considering only local (behind-the-meter) measurements. The proposed approach takes into account the physics of the grid and both real and reactive power (coupled) for voltage regulation and grid loss reduction. The optimization-based approach, termed Local-Quadratic Program (L-QP), is formulated based on the linear power flow equations (LinDistFlow). The proposed L-QP is benchmarked against an approach in which real power is used to maximize the customer benefit, while reactive power is dedicated for voltage regulation. Numerical simulations with the IEEE 13 and IEEE 123 Node Test Feeders, which include realistic time-varying data for residential load and PV generation, demonstrate the technical advantages of the proposed approach.
Recently, wind energy has shown the most significant increase in electric power systems among several other renewable energy sources. Due to the intermittent nature of wind, however, such growth has brought some concerns about Power Quality (PQ). This paper investigates three methods of controlling supercapacitor power to smooth and limit the wind power fluctuations injected into the grid. Methods based on the supercapacitor state of charge, the moving average filter and the Artificial Neural Network (ANN) are presented and compared according to their ability to enhance the grid PQ and voltage profile. The base test system consists of a full-converter based wind turbine connected to a modified IEEE 13 Node Test Feeder. Simulations were run using a real time digital simulator. Results show that all methods notably reduced wind power fluctuations and improved the grid voltage profile. Advantages and disadvantages of each control method are discussed.
This paper presents the effects of Distributed Generators (DGs) on Distribution Systems (DSs), considering different operating scenarios, as well as an analysis of the voltage regulator performance, normally present in DSs. The research has the objective to find the optimal DG coupling point in a DS, in order to achieve power losses reduction and voltage profile improvement, respecting the power quality limits. The system, based on the 13 bus test system of the Institute of Electrical and Electronic Engineers (IEEE), was modeled in a Real-Time Digital Simulator. The DG's optimal allocation point is in the bus 675, which presented the greatest reduction of the losses, thus resulting in an improvement in the system voltage profile.