M. Salauddin Rasel

M. Salauddin Rasel

Auto-generated profile, based on publicly available information

M. Salauddin Rasel

Department of Electronic Engineering, Kwangwoon University, Seoul 139-701, Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Nano Energy
Verified
Journal Article
Closed access
MRM. Salauddin Rasel
M. Salauddin Rasel
PMPukar Maharjan
Pukar Maharjan
Md SALAUDDINMd SALAUDDIN
Md SALAUDDIN
MRM. Toyabur Rahman
M. Toyabur Rahman
HCHyun Ok Cho
Hyun Ok Cho
JPJae Yeong Park
Jae Yeong Park


1 March 2019 in Nano Energy
Verified
Journal Article
Closed access
MRM. Toyabur Rahman
M. Toyabur Rahman
Md SALAUDDINMd SALAUDDIN
Md SALAUDDIN
PMPukar Maharjan
Pukar Maharjan
MRM.S. Rasel
M.S. Rasel
HCHyunok Cho
Hyunok Cho
JPJae Yeong Park
Jae Yeong Park

30 May 2019 in Nano Research
Verified
Journal Article
Closed access
PDF file
PDPartha Sarati Das
Partha Sarati Das
Ashok ChhetryAshok Chhetry
Ashok Chhetry
PMPukar Maharjan
Pukar Maharjan
MRM. Salauddin Rasel
M. Salauddin Rasel
JPJae Yeong Park
Jae Yeong Park
Flexible triboelectric nanogenerators (TENGs)-based pressure sensors are very essential for the wide-range applications, comprising wearable healthcare systems, intuitive human-device interfaces, electronic-skin (e-skin), and artificial intelligence. Most of conventional fabrication methods used to produce high-performance TENGs involve plasma treatment, photolithography, printing, and electro-deposition. However, these fabrication techniques are expensive, multi-step, time-consuming and not suitable for mass production, which are the main barriers for efficient and cost-effective commercialization of TENGs. Here, we established a highly reliable scheme for the fabrication of a novel eco-friendly, low cost, and TENG-based pressure sensor (TEPS) designed for usage in self-powered-human gesture detection (SP-HGD) likewise wearable healthcare applications. The sensors with microstructured electrodes performed well with high sensitivity (7.697 kPa−1), a lower limit of detection (∼ 1 Pa), faster response time (< 9.9 ms), and highly stable over > 4,000 compression-releasing cycles. The proposed method is suitable for the adaptable fabrication of TEPS at an extremely low cost with possible applications in self-powered systems, especially e-skin and healthcare applications.

1 September 2018 in Nano Energy
Verified
Journal Article
Closed access
Md SALAUDDINMd SALAUDDIN
Md SALAUDDIN
RTR.M. Toyabur
R.M. Toyabur
PMPukar Maharjan
Pukar Maharjan
MRM.S. Rasel
M.S. Rasel
JKJ.W. Kim
J.W. Kim
JPJae Yeong Park
Jae Yeong Park

1 December 2017 in Energy Conversion and Management
Verified
Journal Article
Closed access
Md SALAUDDINMd SALAUDDIN
Md SALAUDDIN
MRM.S. Rasel
M.S. Rasel
JKJ.W. Kim
J.W. Kim
JPJae Yeong Park
Jae Yeong Park