Ömer Yonga

Ömer Yonga

Auto-generated profile, based on publicly available information

Ömer Yonga

Yeditepe University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2022 in Joint Diseases and Related Surgery
Verified
Journal Article
Open access
ÖYÖmer Yonga
Ömer Yonga
KMKaya Memişoğlu
Kaya Memişoğlu
TOTolga Onay
Tolga Onay
This study aimed to present the clinical and radiological results of a large patient group operated by Tönnis lateral acetabuloplasty (TLA) for developmental dysplasia of the hip (DDH). The retrospective study was conducted with 66 hips of 41 patients (5 males, 36 females; mean age: 32.3±18 months; range, 11 to 132 months) operated for DDH using the TLA technique in a single center between February 2012 and December 2016. Adductor tenotomy was performed on 52 (79%) hips. There was a need for additional femoral shortening and derotation-varization osteotomy in 14 (21%) hips. Clinical outcomes were evaluated with modified McKay criteria. The acetabular index and lateral migration index for the subluxated hip were calculated, and the femoral head position was evaluated according to Perkin’s line and Shenton’s line. The Severin classification was used to assess the outcome of the hips. The mean follow-up period was 27±11 months. According to the modified McKay criteria for DDH, 77.3% of hips were classified as excellent, 16.6% as good, and 6.1% as fair. The mean acetabular index decreased from 36.1° preoperatively to 18.6° postoperatively. The mean postoperative improvement for the acetabular index was 17.5±5. The lateral migration index improved from 89.7 to 10.6%. A statistically significant difference was determined between the preoperative and postoperative measurements of the acetabular index and lateral migration index (p<0.001). Tönnis lateral acetabuloplasty was found to be safe and effective with a low learning curve, and successful treatment decreases the duration of follow-up required in patients with DDH.

6 July 2014 in Advances in Orthopedics
Verified
Journal Article
Open access
PDF file
HCHalil Ceylan
Halil Ceylan
ÖSÖzgür Selek
Özgür Selek
MIMurat Inanir
Murat Inanir
OYOmer Yonga
Omer Yonga
BOBahar Odabas Ozgur
Bahar Odabas Ozgur
ASAhmet Y. Sarlak
Ahmet Y. Sarlak
This study analyses the results of the treatment with external rotator sparing approach in acetabular fractures to determine whether muscle sparing has a positive impact on functional outcome. 20 patients with a mean age of 45.9 years (range: 26–64) that had been treated for displaced acetabular fractures were included in this series. Short Musculoskeletal Function Assessment (SMFA) questionnaire and hip muscle strength measurement were done at the 24-month of follow-up period. The radiographic results at the final followup were excellent in 9 hips (45%), good in 6 hips (30%), fair in 4 hips (20%), and poor in one hip (5%) according to the criteria developed by Matta. The average SMFA score for all of the patients was 18.3 (range: 0–55.4). The mean dysfunctional and bother indexes were 17.2 and 20.6, respectively. The overall muscle strength deficit was 11.8%. The greatest loss of strength was in internal rotation. In patients with better postoperative reduction quality of acetabular fracture, peak torque, and maximum work of hip flexion, extension and also internal rotation maximum work deficit were significantly lower(P<0.05). Accurate initial reduction and longer postoperative muscle strengthening exercise programs seem critical to decrease postoperative hip muscle weakness after acetabular fractures.

4 January 2021 in Acta Orthopaedica et Traumatologica Turcica
Verified
Journal Article
Open access
BABudak Akman
Budak Akman
MGMelih Güven
Melih Güven
BKBarış Kadıoğlu
Barış Kadıoğlu
NÖNamık Kemal Özkan
Namık Kemal Özkan
ÖYÖmer Yonga
Ömer Yonga
BÖBurak Özturan
Burak Özturan
Objective: The aim of this paper was to investigate the mid-term results of a modified Trapdoor procedure that can allow grafting of the femoral head without surgical hip dislocation in the management of patients with osteonecrosis of the femoral head. Methods: 16 hips of 12 patients (7 female, 5 male; mean age = 38.5 ± 10.7) surgically treated by the new modification of Trapdoor procedure were retrospectively reviewed and included in the study. Based on the Association Research Circulation Osseous (ARCO) classification system, seven hips (43.7%) were stage 2, and nine hips (56.3%) were stage 3. The mean follow-up was 48.4 ± 25.7 months (range = 12-107). All the patients were evaluated postoperatively at the 6th week, 3rd month, 6th month, 1st year, and annually thereafter until their final follow-up. Clinical assessment was performed using the Harris Hip scoring (HHS) system, Non-Arthritic Hip score (NAHS) and Visual analogue pain scale (VAS). At the final follow-up, degenerative changes were examined according to the Kellgren-Lawrence scale. Results: ThemeanHHS increased from53.43 ± 9.0 (range = 36-67) preoperatively to 83.81 ± 6.1 (range = 72-95) at the final follow-up (P < 0,001). Themean NAHS increased from 51.5 ± 8.2 (range = 36.25-61.25) preoperatively to 86 ± 3.2 (range = 81.5-90) (P < 0,001) at the final follow-up. The mean preoperative VAS decreased from 7.85 ± 0.9 (range = 6.45-9.5) to 3.05 ± 0.9 (range = 1.6-5.2) (P < 0,001) at the final follow-up. 13 hips demonstrated 80 and higher scores according toHHS. In the remaining three hips (ARCOstage 3), the mean postoperative HHS, NAHS, and VAS scores were 76, 82, and 3,2 respectively. According to Kellgren-Lawrence scale, three hips (18,75%) were determined as grade 0, 10 hips (62.5%) as grade 1, and 3 hips (18.75%) as grade 2. Conclusion: The Modified Trapdoor procedure without surgical hip dislocation seems to be a suitable technique with favorable clinical outcomes for the treatment of ARCO stage 2 and stage 3 osteonecrosis of the femoral head. Level of Evidence: Level IV, Therapeutic Study Cite this article as: Akman B, Güven M, Kadıoğlu B, et al. A new modification of the Trapdoor Procedure without surgical hip dislocation in the management of patients with osteonecrosis of the femoral head: A retrospective case series. Acta Orthop Traumatol Turc 2021; 55(4): 299–305.

12 July 2024 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
ÖYÖmer Yonga
Ömer Yonga
MGMelih Güven
Melih Güven
BABudak Akman
Budak Akman
KYKorcan Yüksel
Korcan Yüksel
Background: The acetabular version is crucial for hip function, and its accurate assessment is necessary for treating patients with hip disorders. Current studies reveal discrepancies in the precision of quantitative radiographic measurements versus CT measurements, but there is a lack of focused analysis on anteverted versus retroverted hips. This study aims to fill this gap by directly comparing the reliability of these two methods in assessing varied hip configurations. Questions/purposes: (1) How reliable are quantitative radiographic and CT methods in measuring the acetabular version angle? (2) Is there any difference in the reliability of acetabular version angle measurements using radiography compared with CT in anteverted and retroverted hips? (3) What is the extent of variation in acetabular version measurements when quantitative radiographic and CT methods are compared in anteverted and retroverted hips? Methods: We searched our image archives for patients who had received both radiographs and CT scans between January 2020 and June 2022 and found 84 patients who met the criteria. From these patients, we selected those who presented with hip pain of different causes and who had no previous elective and/or hip trauma surgery, no hip dysplasia, and results from adequate radiographic examinations. Accordingly, 73% (61 of 84) of the patients were included in this study, and angle measurements were performed on both hips of these patients (122 hips). Standardized positioning was meticulously verified for all plain radiographs and CT scans utilized in the measurement process. We measured quantitative angles and assessed qualitative signs of retroversion, including crossover, posterior wall, and ischial spine findings. We considered a hip with at least one of these findings a retroverted hip, and the hips without these findings were included in the anteverted hip group. Three clinicians took measurements independently. Measurement reliability and agreement were examined using intraobserver and interobserver intraclass correlation coefficients (ICCs), with statistical analyses including paired and independent t-tests. To investigate the reliability of quantitative radiographic and CT methods, we assessed both intraobserver and interobserver agreements. To explore the reliability disparities in measuring the acetabular version via radiography and CT in anteverted and retroverted hips, we analyzed the agreement between measurements from both modalities in the hip groups. Furthermore, to evaluate the degree of variation in acetabular version measurements when comparing quantitative radiographic and CT methods in anteverted and retroverted hips, we utilized paired and independent t-tests to examine the measurement differences within these hip categories. The difference between radiographic and CT measurements was also evaluated by Bland-Altman analysis. Results: Quantitative radiographic measurements showed intraobserver and interobserver reliabilities with ICCs of 0.87 (95% CI 0.84 to 0.91) and 0.78 (95% CI 0.75 to 0.82), respectively, and CT measurements demonstrated higher reliabilities with ICCs of 0.92 (95% CI 0.90 to 0.93) and 0.91 (95% CI 0.89 to 0.92), respectively. The reliability of measuring the acetabular version in anteverted hips was moderate, with an ICC of 0.59 (95% CI 0.49 to 0.68). In contrast, retroverted hips showed an ICC of -0.41 (95% CI -1.17 to 0.08), indicating a lack of consistency between quantitative radiographic and CT measurements. Variation in measurement on plain radiographs in anteverted hips was less than that of retroverted hips (mean ± SD absolute difference between anteverted hips and retroverted hips 3° ± 3° versus 6° ± 4°; p = 0.0001), indicating greater variability in the radiographic measurement of retroverted hips. According to Bland-Altman analysis, we observed that the difference between radiographic and CT measurements was well outside the CI, especially in retroverted hips. Conclusion: Although quantitative radiographic measurement demonstrates acceptable intraobserver and interobserver reliabilities, its precision is lower than that of CT-based measurements. Specifically, quantitative radiographic methods are prone to a larger margin of error in retroverted hips. For more precise assessments of acetabular version, especially in retroverted hips, we recommend using CT measurement instead of the radiographic method. Level of Evidence: Level III, diagnostic study.

12 August 2026 in Experimed
Verified
Journal Article
Closed access
ÖYÖmer Yonga
Ömer Yonga
BÇBehiç Çelik
Behiç Çelik
FAFaik Altıntaş
Faik Altıntaş
Objective: This study aimed to compare functional outcomes, complication rates, and perioperative parameters of Cable Grip Plate and Grip Cable techniques for greater trochanter fixation in elderly patients undergoing partial hip replacement for intertrochanteric femur fractures.Materials and Methods: This study included 82 patients aged \> 60 years treated between January 2020 and December 2023. Greater trochanter fixation was performed using a cable grip plate (n=45) or a grip cable system (n=37). Demographics, operative time, intraoperative blood loss, early and late complications, revision rates, functional outcomes (Harris Hip Score (HHS), Parker Mobility Score (PMS), Visual Analog Scale (VAS)), and walking aid use were compared between groups.Results: Operative time and blood loss were significantly higher in the cable grip plate group (p=0.001 and p\<0.001, respectively). Nevertheless, this group demonstrated superior functional outcomes, including higher HHS (82.7 ± 4.8 vs 79.6 ± 5.5, p=0.008), improved PMS (p=0.006), lower VAS scores (p=0.032), and earlier return to activities of daily living (p=0.009). Late complications were more frequent in the Grip Cable group (p=0.030), whereas revision rates and mortality were similar.Conclusion: Despite longer operative time and increased blood loss, cable grip plate fixation was associated with better functional recovery and fewer late complications, supporting its use for greater trochanter stabilization in this population.

1 January 2021 in TOTBID Dergisi
Verified
Journal Article
Closed access
ÖYÖmer Yonga
Ömer Yonga
BKBarış Kadıoğlu
Barış Kadıoğlu
MGMelih Güven
Melih Güven