Pingxian Wang

Pingxian Wang

Auto-generated profile, based on publicly available information

Pingxian Wang

Department of Medical Insurance, the Affiliated Hospital of Guizhou Medical University, Guiyang, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
PLPinggui Lei
Pinggui Lei
JMJujiang Mao
Jujiang Mao
PWPingxian Wang
Pingxian Wang
Lei P, et al. Korean J Radiol. 2020 Jul;21(7):929-930. https://doi.org/10.3348/kjr.2020.0426

31 August 2020 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PLPinggui Lei
Pinggui Lei
PZPiaochen Zhang
Piaochen Zhang
HXHengtian Xu
Hengtian Xu
QLQianijao Liu
Qianijao Liu
YWYan Wang
Yan Wang
JJJun Jiao
Jun Jiao
OBJECTIVE: To study the diagnostic value of real-time ultrasound shear wave elastography (US-SWE) in evaluating the histological stages of nonalcoholic fatty liver disease (NAFLD) in a rabbit model. MATERIALS AND METHODS: Twenty-one 8-week-old rabbits were fed a high-fat, high-cholesterol diet (experimental groups), and seven rabbits were fed a standard diet (control group). All rabbits underwent real-time US-SWE at various time points to document the histological stages of NAFLD. We categorized the histological stages as normal, NAFL, borderline nonalcoholic steatohepatitis (NASH), and NASH. We measured the elastic modulus of the liver parenchyma and analyzed the diagnostic efficacy of real-time US-SWE using the area under receiver operating characteristic curve (AUC) for the four histological stages. RESULTS: The mean, minimum, and maximum elastic modulus increase for NAFL, borderline NASH, and NASH. For the mean, minimum, and maximum elastic modulus, AUCs are 0.891 (95% confidence interval [CI]: 0.716–0.977), 0.867 (95% CI: 0.686–0.965), and 0.789 (95% CI:0.594–0.919) for differentiating normal liver from liver with NAFLD, respectively; AUCs are 0.846 (95% CI: 0.660–0.954), 0.818 (95% CI: 0.627–0.937), and 0.797 (95% CI:0.627–0.913) for differentiating normal liver or liver with NAFL from liver with borderline NASH or NASH, respectively; AUCs are 0.889 (95% CI: 0.713–0.976), 0.787 (95% CI: 0.591–0.918), and 0.895 (95% CI:0.720–0.978) for differentiating liver with NASH from liver with lower severity NAFLD or normal liver, respectively. CONCLUSIONS: Real-time US-SWE is an accurate, noninvasive technique for evaluating the histological stages of NAFLD by measuring liver stiffness. We recommend using the mean elastic modulus to differentiate the histological stages, with the minimum and maximum elastic modulus as valuable complements.

1 January 2021 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
QLQianjiao Liu
Qianjiao Liu
HNHongfang Nie
Hongfang Nie
HXHengtian Xu
Hengtian Xu
PWPingxian Wang
Pingxian Wang
PLPinggui Lei
Pinggui Lei
Liu Q, et al. Korean J Radiol. 2021 Jan;22(1):155-158. https://doi.org/10.3348/kjr.2020.0492