Jaume Puigagut

Jaume Puigagut

Auto-generated profile, based on publicly available information

Jaume Puigagut

GEMMA - Environmental Engineering and Microbiology Research Group, Department of Civil and Environmental Engineering, Universitat Politècnica de Catalunya·BarcelonaTech, c/ Jordi Girona 1-3, Building D1, E-08034 Barcelona, Spain

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2007 in Water Research
Verified
Journal Article
Closed access
ACAracelly Caselles-Osorio
Aracelly Caselles-Osorio
JPJaume Puigagut
Jaume Puigagut
ESEmma Segú
Emma Segú
NVNúria Vaello
Núria Vaello
FGFrancesc Granés
Francesc Granés
JOAN GARCIA SERRANOJOAN GARCIA SERRANO
JOAN GARCIA SERRANO

1 November 2015 in Water Research
Verified
Journal Article
Open access
CCClara Corbella
Clara Corbella
MGMiriam Guivernau
Miriam Guivernau
MVMarc Viñas
Marc Viñas
JPJaume Puigagut
Jaume Puigagut
This work aimed at determining the amount of energy that can be harvested by implementing microbial fuel cells (MFC) in horizontal subsurface constructed wetlands (HSSF CWs) during the treatment of real domestic wastewater. To this aim, MFC were implemented in a pilot plant based on two HSSF CW, one fed with primary settled wastewater (Settler line) and the other fed with the effluent of a hydrolytic up-flow sludge blanket reactor (HUSB line). The eubacterial and archaeal community was profiled on wetland gravel, MFC electrodes and primary treated wastewater by means of 16S rRNA gene-based 454-pyrosequencing and qPCR of 16S rRNA and mcrA genes. Maximum current (219 mA/m(2)) and power (36 mW/m(2)) densities were obtained for the HUSB line. Power production pattern correlated well with water level fluctuations within the wetlands, whereas the type of primary treatment implemented had a significant impact on the diversity and relative abundance of eubacteria communities colonizing MFC. It is worth noticing the high predominance (13-16% of relative abundance) of one OTU belonging to Geobacter on active MFC of the HUSB line that was absent for the settler line MFC. Hence, MFC show promise for power production in constructed wetlands receiving the effluent of a HUSB reactor.

1 August 2007 in Ecological Engineering
Verified
Journal Article
Closed access
JPJaume Puigagut
Jaume Puigagut
JCJose Villaseñor Camacho
Jose Villaseñor Camacho
JSJuan José Salas
Juan José Salas
EBEloy Bécares
Eloy Bécares
JOAN GARCIA SERRANOJOAN GARCIA SERRANO
JOAN GARCIA SERRANO

1 August 2018 in Science of The Total Environment
Verified
Journal Article
Closed access
CCClara Corbella
Clara Corbella
JPJaume Puigagut
Jaume Puigagut

1 April 2019 in Science of The Total Environment
Verified
Journal Article
Open access
CCC. Corbella
C. Corbella
MHM. Hartl
M. Hartl
MFM. Fernandez-Gatell
M. Fernandez-Gatell
JPJ. Puigagut
J. Puigagut
In the context of natural-based wastewater treatment technologies (such as constructed wetlands - CW) the use of a low-cost, continuous-like biosensor tool for the assessment of operational conditions is of key importance for plant management optimization. The objective of the present study was to assess the potential use of constructed wetland microbial fuel cells (CW-MFC) as a domestic wastewater COD assessment tool. For the purpose of this work four lab-scale CW-MFCs were set up and fed with pre-settled domestic wastewater at different COD concentrations. Under laboratory conditions two different anodic materials were tested (graphite rods and gravel). Furthermore, a pilot-plant based experiment was also conducted to confirm the findings previously recorded for lab-scale experiments. Results showed that in spite of the low coulombic efficiencies recorded, either gravel or graphite-based anodes were suitable for the purposes of domestic wastewater COD assessment. Significant linear relationships could be stablished between inlet COD concentrations and CW-MFC Ecell whenever contact time was above 10 h. Results also showed that the accuracy of the CW-MFC was greatly compromised after several weeks of operation. Pilot experiments showed that CW-MFC presents a good bio-indication response between week 3 and 7 of operation (equivalent to an accumulated organic loading between 100 and 200 g COD/m2, respectively). Main conclusion of this work is that of CW-MFC could be used as an "alarm-tool" for qualitative continuous influent water quality assessment rather than a precise COD assessment tool due to a loss of precision after several weeks of operation.

1 November 2007 in Chemosphere
Verified
Journal Article
Closed access
VMVíctor Matamoros
Víctor Matamoros
JPJaume Puigagut
Jaume Puigagut
JOAN GARCIA SERRANOJOAN GARCIA SERRANO
JOAN GARCIA SERRANO
JBJosep M. Bayona
Josep M. Bayona