Raffaele Villa

Raffaele Villa

Auto-generated profile, based on publicly available information

Raffaele Villa

Medical Physics Department Fondazione IRCCS San Gerardo dei Tintori Monza Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2017 in Physica Medica
Verified
Journal Article
Closed access
NPNicoletta Paruccini
Nicoletta Paruccini
RVRaffaele Villa
Raffaele Villa
CPClaudia Pasquali
Claudia Pasquali
CSChiara Spadavecchia
Chiara Spadavecchia
ABAntonia Baglivi
Antonia Baglivi
ACAndrea Crespi
Andrea Crespi

1 November 2021 in Physica Medica
Verified
Journal Article
Closed access
NPNicoletta Paruccini
Nicoletta Paruccini
RVRaffaele Villa
Raffaele Villa
NONadia Oberhofer
Nadia Oberhofer
ALAlessandro Loria
Alessandro Loria
MSMichele Signoriello
Michele Signoriello
ATAnnalisa Trianni
Annalisa Trianni

9 March 2023 in Physica Medica
Verified
Journal Article
Open access
CIChiara Ingraito
Chiara Ingraito
RVRaffaele Villa
Raffaele Villa
NPNicoletta Paruccini
Nicoletta Paruccini
EPElena De Ponti
Elena De Ponti
The purpose of this work is to investigate the feasibility of spatio-temporal generalized Model Observer methods for protocol optimization programs in the field of interventional radiography. Two Model Observers were taken under examination: a Channelized Hotelling Observer with 24 spatio-temporal Gabor channels and a Non Pre-Whitening Model Observer with two different implementations of the spatio-temporal contrast sensitivity function. The images of targets, both stationary and in motion, were acquired in fluoroscopic mode using a CDRAD phantom for signal-present images and an homogenous slab of PMMA for signal-absent ones. After the processing, these images were used to build three series of two alternative forced choice experiments, designed to simulate tasks of clinical interest, and submitted to three human observers in order to set a goal on detectability. A first set of images was used for model tuning and subsequently the verified models were validated throughout a second set of images. Results from the validation phase, for both models, show good agreement with the human observer performances (Root Mean Square Error RMSE ≤ 12%). The tuning phase emerges as a crucial step in building models for angiographic dynamic images; the final agreement underlines the good capability of these spatio-temporal models in simulating human performances, allowing to consider them as a useful and worthwhile tool in protocol optimization when dynamic images are involved.

23 September 2025 in Physica Medica
Verified
Journal Article
Open access
LSLaura Soprani
Laura Soprani
VRValentina Ravaglia
Valentina Ravaglia
SDSara Dalmonte
Sara Dalmonte
LALidia Angelini
Lidia Angelini
CBChiara Bassetti
Chiara Bassetti
ASAnna Sardo
Anna Sardo
The most widely used method in Europe to estimate breast dosimetry in mammography is based on Dance's publications. Recently, AAPM and EFOMP joint Task Group 282 (TG282) has published a new breast dosimetry model, which improves the accuracy in Average Glandular Dose (AGD) estimation. This multicentre study aims to evaluate variations in AGD between conventional and new dosimetry across different modalities and mammography systems. Measurements were conducted on 74 mammography systems from six vendors, installed in hospitals across Italy. Each facility used its own equipment while adhering to the same protocol and spreadsheets. Tube output and Half-Value Layer (HVL) were measured in the two configurations for Digital Mammography (DM), Digital Breast Tomosynthesis (DBT), and Contrast-Enhanced Mammography (CEM). Exposures were performed using a breast-shaped PMMA phantom of different thicknesses. Data were centrally collected to compute AGD using appropriate correction factors for conventional dosimetry and the BreastAGD282 software for TG282 dosimetry, using EU legacy model. The sample allows for the identification of typical AGD values for both methodologies. The study highlights a reduction in median AGD with the new dosimetry model compared to Dance method across all modalities and vendors. Furthermore, the reduction magnitude depends on x-ray beam quality, modality and compressed breast thickness, ranging from 6.1-8.4 % at 21 mm to 27.3-38.3 % at 90 mm. The new TG282 dosimetry model showed a reduction in the estimated median AGD. Notably, the magnitude of this reduction depended on x-ray beam quality, modality and compressed breast thickness.

1 October 2024 in Physica Medica
Verified
Journal Article
Open access
SCS. Carminati
S. Carminati
STSara Trivellato
Sara Trivellato
CIC. Ingraito
C. Ingraito
GMG. Montanari
G. Montanari
SMS. Morzenti
S. Morzenti
EPE. De Ponti
E. De Ponti
Myeloablative Total Body Irradiation (TBI) used in our Institution, as part of the conditioning scheme for haematopoietic stem cell transplantation, is an extended-distance supine technique that has been implemented using a 15 MV LINAC beam, lead lung compensators, PMMA, and water bolus to improve homogeneity. This study reviews in-vivo dosimetry (IVD) over 10 years of treatments, assessing the technique's robustness, accuracy, and efficiency. A 2-lateral opposite fields plan was calculated from planning CT with validated Oncentra TPS (Elekta AB, Sweden). Monitor units (MUs), lung compensators shape and thickness were calculated to deliver the prescription dose (12 Gy in 6 bi-daily fractions or 9.9 Gy in 3 daily fractions) to the patient's abdomen midline at the umbilical level, maintaining lung dose within ±5 % range of prescription. Data from 103 patients, of which more than 87 % were pediatric, were retrieved and analyzed for a total of 537 treatment fractions. The impact of IVD omission was evaluated, supposing doing it only once or in the first two fractions, if necessary. Median ΔMU from planned was -1.2 %. Median percentage dose deviation from prescription in 6 anatomical regions was below 2 %. IVD omission could have resulted in an increase of 7 patients registering at least one anatomical region outside the ±5 % dose range at the end of treatment. It is possible to confirm the implemented technique's robustness and accuracy in delivering the prescribed dose under IVD monitoring. Nevertheless, this technique and associated IVD are time-consuming and IVD omission could be assessed with limited drawbacks.

7 July 2026 in Journal of Imaging Informatics in Medicine
Verified
Journal Article
Closed access
RVRaffaele Villa
Raffaele Villa
NPNicoletta Paruccini
Nicoletta Paruccini
EPElena De Ponti
Elena De Ponti