Charles Tarrio

Charles Tarrio

Auto-generated profile, based on publicly available information

Charles Tarrio

National Institute of Standards and Technology (United States)

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2007
Verified
Conference Paper
Open access
PDF file
SHS B Hill
S B Hill
IEIvan Ermanoski
Ivan Ermanoski
CTC Tarrio
C Tarrio
TLT B Lucatorto
T B Lucatorto
TMTheodore E Madey
Theodore E Madey
MCManish Chandhok
Manish Chandhok
Endurance testing of Ru-capped multilayer mirrors (MLMs) at the NIST synchrotron facility has revealed that the damage resulting from EUV irradiation in a water-dominated environment is nonlinear and may be influenced by competing oxidation and carbon-deposition processes. Concurrent results from two different environmental chambers reveal non-intuitive relationships between reflectivity loss and the admitted water-vapor partial pressure, the ambient background-gas composition, the presence or absence of hot filaments in the chamber, the EUV intensity and the irradiation dose. We discuss possible mechanisms and propose further experiments to test them. Determining the MLM lifetime from accelerated tests is a very difficult task. It is crucial that any lifetime testing procedure involves duplicate exposures for consistency, and, if possible, testing in multiple facilities.

1 October 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DKDeepak Kumar
Deepak Kumar
DSDan Stutman
Dan Stutman
KTKevin Tritz
Kevin Tritz
MFMichael Finkenthal
Michael Finkenthal
CTCharles Tarrio
Charles Tarrio
SGSteven Grantham
Steven Grantham
A free standing transmission grating based imaging spectrometer in the extreme ultraviolet range has been developed for the National Spherical Torus Experiment (NSTX). The spectrometer operates in a survey mode covering the approximate spectral range from 30 to 700 Å and has a resolving capability of δλ/λ on the order of 3%. Initial results from space resolved impurity measurements from NSTX are described in this paper.

1 January 2003 in Journal of Research of the National Institute of Standards and Technology
Verified
Journal Article
Closed access
ZLZ.H. Levine
Z.H. Levine
CTC. Tarrio
C. Tarrio
DPD.J. Paterson
D.J. Paterson
IMI. McNulty
I. McNulty
TLT.M. Levin
T.M. Levin
JRJ.J. Rehr
J.J. Rehr
The mass absorption coefficients of tungsten and tantalum were measured with soft x-ray photons from 1450 eV to 2350 eV using an undulator source. This region includes the M3, M4, and M5 absorption edges. X-ray absorption fine structure was calculated within a real-space multiple scattering formalism; the predicted structure was observed for tungsten and to a lesser degree tantalum as well. Separately, the effects of dynamic screening were observed as shown by an atomic calculation within the relativistic time-dependent local-density approximation. Dynamic screening effects influence the spectra at the 25 % level and are observed for both tungsten and tantalum. We applied these results to characterize spatially-resolved spectra of a tungsten integrated circuit interconnect obtained using a scanning transmission x-ray microscope. The results indicate tungsten fiducial markers were deposited into silica trenches with a depths of 50 % and 60 % of the markers' heights.


2 March 2023 in Solar Physics
Verified
Journal Article
Closed access
PDF file
CTCharles Tarrio
Charles Tarrio
TLThomas B. Lucatorto
Thomas B. Lucatorto
RBRobert F. Berg
Robert F. Berg
DNDale E. Newbury
Dale E. Newbury
NRNicholas W. M. Ritchie
Nicholas W. M. Ritchie
FEFrank Eparvier
Frank Eparvier

1 July 2011 in Review of Scientific Instruments
Verified
Journal Article
Closed access
CTC. Tarrio
C. Tarrio
SGS. Grantham
S. Grantham
SHS. B. Hill
S. B. Hill
NFN. S. Faradzhev
N. S. Faradzhev
LRL. J. Richter
L. J. Richter
TLT. B. Lucatorto
T. B. Lucatorto
Before being used in an extreme-ultraviolet (EUV) scanner, photoresists must first be evaluated for sensitivity and tested to ensure that they will not contaminate the scanner optics. The new NIST facility described here provides data on the contamination potential of the outgas products of a candidate resist by simultaneously irradiating a multilayer optic and a nearby resist-coated wafer with EUV radiation. The facility can also be used without changing its configuration to provide accurate resist dose-to-clear measurements. Detailed, real-time information on the rate of contamination growth is given by a unique, in situ imaging ellipsometer. We will describe the optical layout, mechanical design, and capabilities of the beamline, finally presenting experimental examples of its capabilities.