Chikara Yamashita

Chikara Yamashita

Auto-generated profile, based on publicly available information

Chikara Yamashita

Current Collection Maintenance, Power Supply Technology Division, Railway Technical Research Institute

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2020 in Quarterly Report of RTRI
Verified
Journal Article
Open access
PDF file
MTMizuki Tsunemoto
Mizuki Tsunemoto
MSMasatoshi Shimizu
Masatoshi Shimizu
KIKeisuke Irikura
Keisuke Irikura
HMHiroaki Morimoto
Hiroaki Morimoto
CYChikara Yamashita
Chikara Yamashita
KIKunio Ikeda
Kunio Ikeda
Compound catenary systems on Shinkansen lines will soon enter a period where they will have to be replaced on a large-scale. In order to facilitate replacement and reduce maintenance costs, compound catenary systems can be replaced with simple catenary systems. This study explores new types of simple catenary systems developed for running speeds of about 320 km/h, which is the maximum Shinkansen commercial operating speed. In addition, a simple catenary system for operation up to 360 km/h is also being developed.

15 December 2022 in Tribology Online
Verified
Journal Article
Open access
PDF file
CYChikara Yamashita
Chikara Yamashita
KNKoki Nemoto
Koki Nemoto
TOTakuya Ohara
Takuya Ohara
In order to suppress electric wear of current collecting materials such as a contact wire and a contact strip in an electric railway, it is necessary to estimate the relationship between current and melting volume at a contact loss point. In this paper, we focused on a molten bridge which is considered as the main factor of electric wear at the contact loss point. And we proposed the estimation method of melting volume of contact wire and contact strip; in which film resistance is considered by using the relationship between the electric potential and the temperature at the contact spot. From estimation results, it is found that the melting volume increases as current increases, and that it increases as a contact boundary factor decreases. In addition, the authors carried out wear tests and measure a melting depth, a melting radius, and a melting volume under two conditions of current. From wear test results, experimental values of melting volume of the contact wire were in the range where contact boundary factor α was estimated from 0.90 to 0.94.

15 November 2019 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
MYMinoru Yokoyama
Minoru Yokoyama
TSTomoyuki Shimono
Tomoyuki Shimono
CYChikara Yamashita
Chikara Yamashita
SNSei Nagasaka
Sei Nagasaka
TOTakuya Ohara
Takuya Ohara

1 January 2000 in The proceedings of the JSME annual meeting
Verified
Journal Article
Closed access
PDF file
CYChikara Yamashita
Chikara Yamashita