Yu-Xin Wei

Yu-Xin Wei

Auto-generated profile, based on publicly available information

Yu-Xin Wei

College of Electronic and Optical Engineering and the College of Flexible Electronics (Future Technology), Nanjing University of Posts and Telecommunications, Nanjing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
成杨成 杨
成 杨
CGChu-Ming Guo
Chu-Ming Guo
YWYu-Xin Wei
Yu-Xin Wei
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
Second harmonic wave (SHW) generation is a nonlinear optical phenomenon wherein electromagnetic radiation undergoes a process of doubling its frequency. A multi-task Janus metastructure (MJMS) based on liquid crystal (LC) tunable defects is introduced in this paper, enabling temperature detection and biosensing. Due to the asymmetric arrangement of dielectrics, MJMS exhibits Janus characteristics in both forward and backward directions. Significant enhancement in the output efficiency of SHW can be achieved through the adjustment of LC defects and structural design. When the cavity under test is filled with air, high-precision temperature sensing can be achieved by detecting the shift of the SHW’s peak (SHWP), with a detection range of 15 °C ~ 40 °C. The highest sensitivity (S) can reach 0.00164 THz/°C. When the cavity under test is filled with analytes, different types of waterborne bacteria can be identified on the forward scale by the amplitude shift of SHWP, with a measurement range of 1.365 ~ 1.425, S = 0.9826 /RIU. On the backward scale, MJMS can detect glucose solution with concentrations ranging from 0 g/L ~ 400 g/L with a detection range of 1.33 ~ 1.38, S = 3.402 /RIU. This MJMS has the potential to drive breakthroughs in electromagnetic detector design, opening up new avenues for exploring SHW applications and LC research.

13 August 2025 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
CWChuan-Qi Wu
Chuan-Qi Wu
JSJun-Yang Sui
Jun-Yang Sui
YWYu-Xin Wei
Yu-Xin Wei
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
In this paper, a multitasking layered nonlinear metastructure (NM) with polarization conversion (PC) and multi-physical quantities detection (MQPD) is investigated, comprising two common media, nonlinear Kerr medium and indium antimonide (InSb). The incident electromagnetic waves (EWs) are considered linear waves. Considering the temperature-tunable property of InSb, the transmission phase difference and polarization form can be tuned by the temperature. When the temperatures are adjusted to 286 K or 300 K, the transmitted EWs can be converted to circular polarization waves (CPWs), classified as left-handed CPWs and right-handed CPWs, whose polarization energy transmission rates (PER) are 0.9147 and 0.9128. With the introduction of the nonlinear Kerr medium, the NM will have the feature of tunability for the electromagnetic intensity, which can be employed to encrypt the polarization information and adjust the PER peak related to the performance of MQPD. Moreover, With EWs being incident, the detection of the refractive index, incident angle, and temperature can be realized by confirming the frequency of the special EWs PER peak. The relevant detection ranges are 1.45~2.20, 246~296 K, and 72°~82°. This multifunctional layered NM integrating PC and MQPD can not only be applied to the antenna fields but also has certain application scenarios in industrial production and detection.

26 August 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CGChu-Ming Guo
Chu-Ming Guo
成杨成 杨
成 杨
XLXiang Li
Xiang Li
YWYu-Xin Wei
Yu-Xin Wei
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
A novel hyperstructure (HS) based on periodically poled strontium barium niobate (SBN) is proposed for second harmonic generation, showcasing its multi-functionality in multi-window and multi-biomass sensing applications. Through meticulously designed HS, distinct measurement windows are achieved in both the fundamental wave (FW) and the second harmonic wave (SHW). Within the FW window, a refractive index (RI) range of 1.35~1.4 is measured, enabling the differentiation of various stages of malaria by detecting the RI of red blood cells. The SHW window facilitates RI measurements in the range of 1.53~1.56, allowing the discrimination between healthy and malignant cells by detecting the RI of cell nuclei. Furthermore, the HS proposed enables the measurements of the thickness of air film, with measurement ranges of 9 μm~9.5 μm for the FW and 9.5 μm~10.1 μm for the SHW. The multi-functionality of this HS demonstrates extensive potential applications in medical diagnostics and beyond. Additionally, it presents an approach for real-time, and label-free detection in the field of biomedical research.

24 February 2025 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
CGChu-Ming Guo
Chu-Ming Guo
成杨成 杨
成 杨
YWYu-Xin Wei
Yu-Xin Wei
XLXiang Li
Xiang Li
Haifeng ZhangHaifeng Zhang
Haifeng Zhang
In this letter, an innovative silicon-based metastructure (SBMS) is proposed for second harmonic generation (SHG) to enable the detection of refractive index (RI) and coronavirus disease 2019 (COVID-19) solution concentrations (SC). Utilizing the transfer matrix method (TMM) for analysis and computation, RI sensing is achieved, unveiling the sensitivity of SBMS towards variations in COVID-19 SC. Subsequently, a model correlating COVID-19 SC with the frequency of the second harmonic wave (SHW) transmission peak (TP) is established. Specifically, SBMS demonstrates a RI sensing detection range from 1.1 to 1.4, with a sensitivity of up to 16.946 THz/RIU and an optimal quality factor of $1.66 \times 10 ^{\mathbf {5}}$ . Additionally, the relevant values for COVID-19 SC detection are 0 mM to 525 mM (where M is molarity, and 1 M =1 mol/L), 0.71225 THz/M, and $1.66 \times 10 ^{\mathbf {5}}$ . The SBMS not only provides an important theoretical foundation for the development of novel virus detection technologies but also expands new possibilities for the application of SBMS in the biomedical field.