Unmanned Aerial Vehicles used by military are generally designed with very high reliability and have multiple redundancy of software and hardware equipment because they are intended to operate in hostile environment. But, relatively low cost UAVs used commercially are not equipped with such systems. Usually, micro UAVs weight less than 2kg are equipped with on-board miniature sensor and operate without any hardware redundancy and thus could reduce their reliability. Some of these commercial UAVs that operate in populated areas will cause damage and fatality if faulty system occurred. Hence there is a need for on-board fault detection and isolation system without degradating the UAV flyability and its cost. Analytical redundancy or model reference method of fault detection algorithms could be implemented as most UAVs are microcontroller controlled. Together, with the availability of miniature sensors could provide an ideal platform for implementing fault detection. In this paper, the development of fault detection through residual generation algorithm is implemented with data fusion from miniature sensors. Some of these sensors are already installed within the autopilot system which reduce the amount of additional sensors needed. Identification of fault in the elevator is simulated experimentally and fault detection rate is monitored. From the implemented algorithm, the data fusion from additional sensors shows improvement in fault detection rate.
The degrading performance of actuators in small unmanned aerial Vehicle (UAV) is often left unnoticed because it is masked by autopilot control. The faulty actuator will only be detected when the actuator has been severely damaged. If it occurs during flight, the UAV will be lost, same goes with the valuable data on the board. Usually, a pre-flight check is performed before each flight to ensure the overall condition of the UAV including the actuators. The actuator health deterioration is difficult to be recognized by visual inspection. This paper presents a method to detect the health of the actuator through the integration of Built-in Test System (BITE) using offline model estimation method. Least square regression estimation was performed on the healthy actuator for training data using fixed and increasing input signal. The fault is then simulated to test the training data accuracy in detecting actuator fault. An analysis is performed to show the advantage and disadvantage of each technique used. The estimation technique described was able to detect faulty actuator which could then be integrated with on-board health detection system in order to increase the reliability of the UAV.
Acute Leukemia has become the most common type of cancer among children below 15 years old in Malaysia. Yet, its main etiologies are unexplained, leading researchers to relate its occurrence to environmental factors. Therefore, residential proximity to Overhead Transmission Lines (OHTL) was considered as an environmental risk factor contributing in the occurrence of Acute Leukemia due to its magnetic fields production. The objective of this research paper is to investigate the correlation of Acute Leukemia and residential magnetic field exposure and proximity to OHTL. Distance was measured using Google Earth software and magnetic field exposure was assessed using a magnetic field survey meter. Subjects enrolled in this study were children below 15 years old who received their medical treatment in Universiti Kebangsaan Malaysia Hospital (HUKM) and Kuala Lumpur General Hospital (GHKL). Case subjects are children diagnosed with Acute Leukemia while control subjects are children diagnosed with other Acute Illnesses. The analysis showed that the correlation is statistically insignificant between Acute Leukemia and both variables: Residential Magnetic Field Exposure (OR 0.82, 95% CI: 0.33-2.00, p= 0.66, X2= 0.20), Residential Proximity (OR 0.88, 95% CI: 0.35-2.22, p= 0.80, X2= 0.068). In conclusion, it was found that residential proximity to OHTL does not constitute any risk to children's health. Additionally, other socioeconomic factors which are contributing in the occurrence of Acute Leukemia, makes any previously proved relationship subjected to chance or methodology misconduct.
Electric and magnetic fields (EMFs) exist whenever electricity is generated, transmitted, distributed and used. Recent worldwide studies have raised questions about the possible health effects from power frequency EMFs. Information of such studies and websites of concerned groups are readily available from the Internet. These have contributed to the growth of public concerns on their possible health effects. To date, there are still many questions that heed to be answered to determine their hazards to human and the setting of limits to EMF exposures from long term, low dose power frequency electric and magnetic fields. There is, however a general agreement that better information and sincere applied research are needed in order to resolve these issues. This paper describes the activities of the EMF Research Group, Universiti Tenaga Nasional, the university owned by Tenaga Nasional Berhad, the major power utility company in Malaysia. EMF Research Group conducts systematic measurements of transmission and distribution facilities owned by Tenaga Nasional Berhad using three-axis EMDEX H meters. The results of the measurements were presented in linear magnitude versus distance graph, 3-dimensional graphs and contour plots for easy reference. Models of the facilities measured are constructed using related software packages and magnetic fields at various operating conditions are predicted. The EMF Research Group also assists Tenaga Nasional Berhad and its subsidiaries in addressing public concerns voiced through the mass media or letters sent directly to the company. Besides addressing health issues, this paper also discusses complains from other industrial and commercial facilities whose operations were affected due to high EMFs. The paper describes the measurements conducted and remedial actions recommended. Author(s) Said, I. Univ. Tenaga Nasional, Selangor, Malaysia Farag, A. ; Hussain, H. ; Rahman, N.A. ; Hashim, T.J.