Qingchuan Ma

Qingchuan Ma

Auto-generated profile, based on publicly available information

Qingchuan Ma

Beihang University

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2020 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
QMQingchuan Ma
Qingchuan Ma
EKEtsuko Kobayashi
Etsuko Kobayashi
BFBowen Fan
Bowen Fan
KNKeiichi Nakagawa
Keiichi Nakagawa
ISIchiro Sakuma
Ichiro Sakuma
HSHideyuki Suenaga
Hideyuki Suenaga

6 February 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
QMQingchuan Ma
Qingchuan Ma
EKEtsuko Kobayashi
Etsuko Kobayashi
HSHideyuki Suenaga
Hideyuki Suenaga
KHKazuaki Hara
Kazuaki Hara
JWJunchen Wang
Junchen Wang
KMKen Masamune
Ken Masamune

22 March 2019 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
QMQingchuan Ma
Qingchuan Ma
EKEtsuko Kobayashi
Etsuko Kobayashi
JWJunchen Wang
Junchen Wang
KHKazuaki Hara
Kazuaki Hara
HSHideyuki Suenaga
Hideyuki Suenaga
KMKen Masamune
Ken Masamune

7 February 2022 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
QMQingchuan Ma
Qingchuan Ma
EKEtsuko Kobayashi
Etsuko Kobayashi
BFBowen Fan
Bowen Fan
KHKazuaki Hara
Kazuaki Hara
Keiichi NakagawaKeiichi Nakagawa
Keiichi Nakagawa
HSHideyuki Suenaga
Hideyuki Suenaga

16 November 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
QMQingchuan Ma
Qingchuan Ma
LJLinhong Ji
Linhong Ji
RWRencheng Wang
Rencheng Wang
Upright walking has both physical and social meanings for paraplegic patients. The main purpose of this study is to reduce the automatic functioning of the powered exoskeleton and enable the user to fully control the walking procedure in real-time, aiming to further improve the engagement of the patient during rehabilitation training. For this prototype, a custom-made hub motor was placed at the bottom of the exoskeleton’s foot, and a pair of crutches with the embedded wireless controller were utilized as the auxiliary device. The user could alternatively press the button of the crutch to control the movement of the leg and by repeating this procedure, the user could complete a continuous walking motion. For safety, an automatic brake and mechanical limitation for maximum step length were implemented. A gait analysis was performed to evaluate the exoskeleton’s motion capability and corresponding response of user’s major muscles. The kinematic results of this study showed that this exoskeleton could assist the user to walk in a motion trend close to the normally walk, especially for ankle joint. The EMG results indicated that this exoskeleton could decrease the loading burden of the user’s lower limb while requiring more involvements of upper-limb muscles to maintain balance while walking.

4 October 2019 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
KHKazuaki Hara
Kazuaki Hara
QMQingchuan Ma
Qingchuan Ma
HSHideyuki Suenaga
Hideyuki Suenaga
EKEtsuko Kobayashi
Etsuko Kobayashi
ISIchiro Sakuma
Ichiro Sakuma
Ken MasamuneKen Masamune
Ken Masamune
Impracticable workspaces and cumbersome hardware limit the practical application of the currently available orthognathic surgical robots in a clinical environment. In this study, a compact and lightweight six degree of freedom (DOF) robot with a workspace limitation mechanism (WLM) was developed, and this paper reports on the technical specifications of the robot, as well as the details of the three experiments performed to validate it. This robot can be easily installed by a single individual and is able to mechanically protect important organs from unintended injury. The results show that this robot functionally limits the workspace travel of the osteotomy device by an average overshoot of 0.8 mm, with a drilling and cutting accuracy of 1 mm and 0.5 mm, respectively. This operational accuracy has the potential to be further improved, making this novel robot a potentially precise and safe medical equipment for orthognathic surgery.