Zakaria Afshar

Zakaria Afshar

Auto-generated profile, based on publicly available information

Zakaria Afshar

Hawaii Natural Energy Institute, University of Hawaii at Mnoa, Honolulu, HI, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZAZakaria Afshar
Zakaria Afshar
IBIndra Bhogaraju
Indra Bhogaraju
HRHamid Rahmanei
Hamid Rahmanei
MFMehdi Farasat
Mehdi Farasat
A novel approach to modeling of and integrating the state-of-charge (SOC) of a battery energy storage system (BESS) into the load frequency control (LFC) of power systems is proposed. By considering the SOC as a state variable in the statespace model of the system, a hierarchical frequency and SOC control scheme is introduced. On top of the primary frequency control (PFC), which is the lowest hierarchy level, the SOC signal is used as the input to a novel primary charge controller (PCC) to prevent the BESS from discharging/charging beyond minimum/maximum allowable ranges. In the middle level of the hierarchy, the secondary frequency control (SFC) loop is augmented to restore the system frequency to its nominal value when the PCC is active. At the top level of the hierarchy, a novel secondary charge controller (SCC) is designed to charge the BESS to its maximum allowable range so that it can continue to contribute to frequency control. System stability is studied using Popov/circle criterion. It is also shown that with multiple distributed energy storage units, following the SOC-balancing principle and by sharing SOC information among the units, only one BESS shall be equipped with the proposed primary and secondary charge controllers. Effectiveness of the proposed hierarchical control in providing fast and stable frequency response under different load and generation conditions is validated through hardware-in-the-loop (HIL) studies.

4 September 2023 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
MZMahmoud Mollayousefi Zadeh
Mahmoud Mollayousefi Zadeh
ZAZakaria Afshar
Zakaria Afshar
GFGholamreza Farahani
Gholamreza Farahani
SBSeyed Mohammad Taghi Bathaee
Seyed Mohammad Taghi Bathaee
Considering the increasing penetration of renewable energy sources (RESs) into power grids, adopting efficient energy management strategies is vital to mitigate the uncertainty issues resulting from the intermittent nature of their output power. This paper aims to resolve the energy management problem by presenting an adaptive robust optimization (ARO) model in which uncertainties associated with solar and wind powers, consumer demand, and electricity prices are considered. The proposed model comprises three stages, one master and two subproblems, using both linearized and convexified power flow equations. Meanwhile, a new optimization-based bound tightening (OBBT) method is also presented to strengthen the relaxation. The proposed solution method solves the microgrid (MG) operation management problem with high accuracy due to considering the convexification method in a reasonable computational time and reducing operational costs compared to conventional models. The numerical results indicate the benefits of the proposed ARO and solution approach over traditional methods.

10 April 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
ZAZakaria Afshar
Zakaria Afshar
Saeed SepasiSaeed Sepasi
Saeed Sepasi
MFMehdi Farasat
Mehdi Farasat

3 November 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
ZAZakaria Afshar
Zakaria Afshar
MFMehdi Farasat
Mehdi Farasat
Existing studies on inertia control depend on knowing or estimating the grid equivalent inertia when renewable energy sources (RESs) are present. To eliminate the need for accurate knowledge or estimate of the grid equivalent inertia, this paper proposes employing the battery energy storage system (BESS) to inject inertia into the grid when RESs are connected to the grid, maintaining the original grid inertia—essentially the value without zero-inertia resources. This is accomplished by designing a model reference adaptive control (MRAC) scheme that uses the power system inertia without zero-inertia resources as a reference to determine the inertia that the BESS must inject. To this end, disturbance observer (DOB)-based MRAC is proposed and integrated into the BESS droop control loop. The DOB estimates load changes based on frequency deviations, and the MRAC uses this information to adjust the BESS output power, ensuring the system inertia and frequency reach the reference. Since the performance of the DOB affects the model reference adaptive controller, the steps to designing the DOB and proper tuning of the adaptation gain, which yields fast dynamics and satisfactory results, are laid out. Moreover, a novel approach is presented for enabling participation of multiple BESSs in inertia control. Real-time simulations are carried out to verify the efficacy of the proposed method in maintaining the grid inertia, and thus the system frequency, around the desired value.

22 May 2026 in IEEE Access
Verified
Journal Article
Open access
AAAdewale W Adegboyega
Adewale W Adegboyega
Saeed SepasiSaeed Sepasi
Saeed Sepasi
ZAZakaria Afshar
Zakaria Afshar
Converter-dominated microgrids exhibit dynamic behaviors during faults and disturbances that differ fundamentally from those of synchronous-machine–dominated systems. This paper develops an electromagnetic transient (EMT) model of a converter-dominated microgrid and applies sequence-domain analysis based on instantaneous symmetrical components to evaluate its dynamic behavior under three scenarios: a single-line-to-ground (SLG) fault, a balanced three-phase short circuit, and a nonlinear load step. Both grid-connected and islanded operating modes are evaluated under matched disturbance types, locations, and timing, using mode-specific source configurations representative of actual microgrid operation. The simulations reveal a pronounced dependence on the operating mode. In grid-connected operation, the grid provides high fault currents, limits neutral shift, and enables rapid voltage recovery. In islanded mode, the effective positive- and zero-sequence impedances are higher, resulting in a reduced fault current, a pronounced zero-sequence voltage, and a larger neutral displacement. The time-domain post-processing clarifies the disturbance structure: SLG faults produce pronounced zero-sequence excursions and stronger phase asymmetry, whereas the 3ϕ faults remain phase-symmetric in the abc domain and are dominated by the positive-sequence response. The nonlinear load produces measurable asymmetry in the projected sequence quantities together with significant harmonic distortion in the currents. The EMT model captures early-cycle asymmetry, control-imposed current limiting, and sequence interactions that cannot be represented in phasor-domain root-mean-square (RMS) studies. These EMT-derived indicators provide grounding- and protection-relevant insights that can support grounding review, relay-sensitivity checks, and control assessment in converter-dominated microgrids.