1 December 2011 in The Journal of Emergency Medicine
24 July 2012 in International Journal of Emergency Medicine
The aim of this study was to determine the usefulness of end tidal carbon dioxide (ETCO2) monitoring in hypotensive shock patients presenting to the ED.
24 February 2009 in International Journal of Emergency Medicine
Background The usual method for initial assessment of an acute asthma attack in the emergency room includes the use of peak flow measurement and clinical parameters. Both methods have their own disadvantages such as poor cooperation/effort from patients (peak flow meter) and lack of objective assessment (clinical parameters). We were looking into other methods for the initial asthma assessment, namely the use of capnography. The normal capnogram has an almost square wave pattern comprising phase 1, slope phase 2, plateau phase 3, phase 4 and angle α (between slopes 2 and 3). The changes in asthma include decrease in slope of phase 2, increase in slope 3 and opening of angle α. Aims Our objective was to compare and assess the correlation between the changes in capnographic indices and peak flow measurement in non-intubated acute asthmatic patients attending the emergency room. Methods We carried out a prospective study in a university hospital emergency department (ED). One hundred and twenty eight patients with acute asthma were monitored with peak flow measurements and then had a nasal cannula attached for microstream sampling of expired carbon dioxide. The capnographic waveform was recorded onto a PC card for indices analysis. The patients were treated according to departmental protocols. After treatment, when they were adjudged well for discharge, a second set of results was obtained for peak flow measurements and capnographic waveform recording. The pre-treatment and post-treatment results were then compared with paired samples t-test analysis. Simple and canonical correlations were performed to determine correlations between the assessment methods. A p value of below 0.05 was taken to be significant. Results Peak flow measurements showed significant improvements post-treatment (p < 0.001). On the capnographic waveform, there was a significant difference in the slope of phase 3 (p < 0.001) and alpha angle (p < 0.001), but not in phase 2 slope (p = 0.35). Correlation studies done between the assessment methods and indices readings did not show strong correlations either between the measurements or the magnitude of change pre-treatment and post-treatment. Conclusion Peak flow measurements and capnographic waveform indices can indicate improvements in airway diameter in acute asthmatics in the ED. Even though the two assessment methods did not correlate statistically, capnographic waveform analysis presents several advantages in that it is effort independent and provides continuous monitoring of normal tidal respiration. They can be proposed for the monitoring of asthmatics in the ED.
23 April 2015 in International Journal of Emergency Medicine
One of the key principles in the recommended standards is that emergency medical service (EMS) providers should continuously monitor the quality and safety of their services. This requires service providers to implement performance monitoring using appropriate and relevant measures including key performance indicators. In Asia, EMS systems are at different developmental phases and maturity. This will create difficultly in benchmarking or assessing the quality of EMS performance across the region. An attempt was made to compare the EMS performance index based on the structure, process, and outcome analysis. The data was collected from the Pan-Asian Resuscitation Outcome Study (PAROS) data among few Asian cities, namely, Tokyo, Osaka, Singapore, Bangkok, Kuala Lumpur, Taipei, and Seoul. The parameters of inclusions were broadly divided into structure, process, and outcome measurements. The data was collected by the site investigators from each city and keyed into the electronic web-based data form which is secured strictly by username and passwords. Generally, there seems to be a more uniformity for EMS performance parameters among the more developed EMS systems. The major problem with the EMS agencies in the cities of developing countries like Bangkok and Kuala Lumpur is inadequate or unavailable data pertaining to EMS performance. There is non-uniformity in the EMS performance measurement across the Asian cities. This creates difficulty for EMS performance index comparison and benchmarking. Hopefully, in the future, collaborative efforts such as the PAROS networking group will further enhance the standardization in EMS performance reporting across the region.
19 February 2016 in International Journal of Emergency Medicine
We designed this study to expand the usage of ultrasound to detect early occurrence of hypovolemia. We explore the potential use of inferior vena cava (IVC) and abdominal aorta (AA) diameter index (IVC:AA) measured ultrasonographically to detect class 1 hypovolemic shock with blood loss less than 15%.ᅟ The aim of this study was to determine the changes in the diameter of inferior vena cava and abdominal aorta in blood donors by using ultrasound, pre and post blood donation. The result of the study would be further explorated to determine the inferior vena cava (IVC) abdominal aorta (Aorta) diameter index (IVC:Aorta). This was a prospective study done in the blood bank of a university hospital. Researcher was trained by a senior radiologist to assess inferior vena cava and abdominal aorta diameter. Fifty-two healthy blood donors were included in the study. Inclusion criteria were same with the blood bank criteria to donate blood. Demographic data and vital signs were taken before the ultrasound measurement done for inferior vena cava and abdominal aorta diameter. Once the volunteers donated their blood of approximately 450 mls; the measurements were repeated using the same methods. There were differences in IVC, abdominal aorta and inferior vena cava:aorta diameters index pre and post donation. With mathematical analysis, we suggested the number of IVC:Aorta index as 1.14±2SD with SD 0.18 as a cut off value for class 1 hypovolemic shock. The IVC:Aorta diameter index can be used as a parameter for detecting early phase (Class 1) of hypovolemic shock.
23 November 2010 in Emergency Medicine Journal
Introduction This study aimed to determine the effectiveness of propofol as an alternative agent for procedural sedation and analgesia (PSA) in the emergency department (ED) and to make a comparison between two different sedative (propofol vs midazolam) drugs used in combination with fentanyl. Objectives To compare outcomes between a combination of fentanyl and propofol with fentanyl and midazolam in patients during and after PSA. Methodology A randomised single blinded control trial carried out in the ED of a university hospital. 40 patients were randomly allocated equally into two groups: group A, 20 subjects received intravenous fentanyl 3 μg/kg as a bolus dose and a titration maximum bolus dose of propofol 1 mg/kg followed by a maximum titration top-up of 0.5 mg/kg if needed; group B, 20 subjects received intravenous fentanyl 3 μg/kg as a bolus dose and a titration maximum bolus dose of midazolam 0.1 mg/kg and a maximum titration top-up of 0.1 mg/kg if needed. The target sedation level was a Ramsay score of 3 or 4. Outcomes included the presence of any adverse events related to PSA and time to discharge. The Mann–Whitney U test was used to compare the two groups. Results None of the patients developed any significant adverse events during and after procedures. The mean length of stay in the propofol and midazolam groups was 29.25 (11.03) and 71.75 (60.64) min, respectively (p<0.001). Conclusion Both propofol and midazolam given at the recommended doses were equally safe and effective for PSA in the ED. The propofol group was discharged much earlier than to the midazolam group.