Vladimir V. Otochkin

Vladimir V. Otochkin

Auto-generated profile, based on publicly available information

Vladimir V. Otochkin

Mechnikov North-Western State Medical University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2025 in Consilium Medicum
Verified
Journal Article
Open access
PDF file
SKSvetlana M. Karelova
Svetlana M. Karelova
MKMilena Y. Kopchak
Milena Y. Kopchak
APAnastasia L. Portniagina
Anastasia L. Portniagina
OFOlga N. Fefelova
Olga N. Fefelova
AYAnna I. Yakovleva
Anna I. Yakovleva
VOVladimir V. Otochkin
Vladimir V. Otochkin
The article is devoted to modern neuroimaging methods in the diagnosis and treatment of epilepsy, including magnetic resonance imaging, positron emission computed tomography, single-photon emission computed tomography and proton magnetic resonance spectroscopy. Their role in identifying epileptogenic foci, monitoring of activity, and planning of surgical treatment is discussed. Current research from scientific databases such as PubMed, ScienceDirect, Neurology Journal, MDPI, and Wiley Online Library is analyzed. Currently, there are two directions of neuroimaging development. On the one hand, scientists are striving to increase the strength of the magnetic field using ultra high-field magnetic resonance imaging 7T, on the other hand, biochemical changes in the ictal, postictal and interictal periods are continuously being studied. Based on these data, a search is underway for biochemical markers that will improve the accuracy of proton magnetic resonance spectroscopy, as well as develop new radiopharmaceuticals. The integrated use of radiation methods makes it possible to increase the accuracy of diagnostic search and achieve more successful surgical outcomes in patients with refractory epilepsy. The article may be of interest to psychiatrists, neurologists, specialists in radiation and functional diagnostics.

11 August 2022 in Medical Visualization
Verified
Journal Article
Closed access
PDF file
VOV. V. Otochkin
V. V. Otochkin
ERE. V. Rozengauz
E. V. Rozengauz
MCM. D. Chernyshev
M. D. Chernyshev
LSL. G. Shevkunova
L. G. Shevkunova
The purpose: to determine the influence of various aspects of the MR-enterography technique on the quality of the obtained images. Materials and methods. MR-enterography was performed in 634 patients for verified Crohn's disease and suspected inflammatory and tumor diseases of the small intestine. The following drugs containing polyethylene glycol (PEG) were used as an oral contrast agent in 573 patients, mannitol in 32 patients, pineapple juice in 16 patients, water in 11 patients, milk in 2 patients. Oral administration of 1500 ml of contrast agent was carried out fractional for an hour in 3 stages of 15 minutes with an interval of 10 minutes. Each patient underwent programs: T2-FIESTA mode in three planes, diffusion-weighted images with a slice thickness of 5 mm through 1 mm. Results. There were no significant differences in the severity of filling of the loops of the small and large intestine in patients taking polyethylene glycol (n = 573) and mannitol (n = 32) as an oral agent. Adequate stretching of the loops of the small intestine was achieved in 94% of patients, the expansion of the loops was considered moderate or unsatisfactory in 11 patients (4%), which is associated with poor tolerance of the contrast agent or individual characteristics of peristalsis. After coloprotectomy in 14 patients, the volume of the contrast agent was reduced to 1000 ml and the time of its administration to 30–40 minutes due to the rapid passage. MR-enterography could not be performed in 27 patients due to intolerance to PEG and mannitol drugs, which caused a pronounced gag reflex. In these cases, we resorted to alternative options in the form of water (n = 11) and pineapple juice (n = 16). Conclusions. A qualitative assessment of the condition of the small intestine is possible only with the exact observance of all aspects of the research methodology in the form of: an interval between the last meal and MR-enterography of at least 8 hours, the volume of oral contrast agent (mannitol or PEG) 1200–1500 ml, taken 60 minutes before the study. When performing MR-enterography in patients after coloprotectomy, we recommend reducing the volume of oral contrast agent to 1000 ml and the preparation time for the study to 30–40 minutes.

16 July 2026 in Consilium Medicum
Verified
Journal Article
Open access
PDF file
VOVladimir V. Otochkin
Vladimir V. Otochkin
ОВОточкин Владимир Вячеславович
Оточкин Владимир Вячеславович
EREvgenij V Rozengauz
Evgenij V Rozengauz
РВРозенгауз Евгений Владимирович
Розенгауз Евгений Владимирович
ASAndrey V. Shestykh
Andrey V. Shestykh
КАКалинина Юлия Андреевна
Калинина Юлия Андреевна
Background. The observation of operated patients after ureteral plastics is a difficult task for radiological diagnostics, as it is not always possible to perform methods with contrast enhancement. Magnetic resonance imaging (MRI) has proven to be an excellent alternative to contrast methods when it is necessary to evaluate intestine, the ureters, to exclude urolithiasis and neoplasms. Aim. To determine the possibilities of MR uro- and enterography in patients after intestinal ureteral plastics. Materials and methods. Magnetic resonance urography was performed in 18 patients with intestinal ureteral plastic surgery who had undergone surgery for various pathologies, including ureteral strictures and neuromuscular ureteral dysplasia. The average age of the patients was 54 years. In addition to standard MRI imaging of the urinary tract, urographic and enterographic programs were performed in the kinematic mode to assess the peristalsis of the intestinal graft. The graft lumen was measured during maximum contraction and relaxation at different levels. Results. The amplitude of the intestinal graft was minimal in the area of the formed anastomoses and was 2 mm. The minimal amplitude was due to postoperative fibrotic changes. The amplitude was maximal in the middle third of the grafts and was 12 mm. In 2 patients, peristalsis was absent on all images in the lower third of the graft, and extended fibrotic strictures and moderate suprastenotic dilation were detected. We considered the fibrous stricture of the intestinal transplant to be significant if the MRI images showed an expansion of the calyceal system. Assessment of the functional state of intestinal grafts was difficult in 2 patients after nephrostomy. Adequate filling of the intestinal graft was achieved only after normal saline was introduced through the nephrostomy tube. Conclusion. MRI is the only modern non-invasive radiological method that allows to assess not only the position and condition of the intestinal transplant walls in patients after ureteral plastic surgery, but also its functional condition.