12 April 2024 in Journal of Energy Chemistry
11 April 2022 in IEEE Transactions on Power Electronics
Temperature monitoring is of paramount importance for guaranteeing the safety and proper operation of lithium-ion batteries. Traditional temperature sensors suffer from heat transfer delay, where internal battery temperature cannot be measured directly. Motivated by this, this letter proposes a novel sensorless temperature estimation method based on broadband impedance spectroscopy. In this letter, pseudorandom sequence (PRS) with finite signal levels is utilized for impedance measurements. The measured impedance information is merged into an impedance-temperature model, which cooperates with a specially designed least-square method for temperature estimation. The proposed framework is robust against interference, whereas simple enough for online implementation. Experimental results suggest excellent estimation accuracy of the proposed method under different circumstances.
30 August 2022 in IEEE Transactions on Industrial Electronics
Broadband battery impedance spectroscopy brings valuable information that facilitates states estimation and fault diagnosis, which are of extensive research interests at present. Pseudorandom sequence (PRS) provides a promising tool for realizing online battery impedance measurements, yet it suffers from an insufficient signal-to-noise ratio (SNR). Motivated by this, this article proposes a novel hybrid pseudorandom sequence (HPRS) to boost the signal power in the low-frequency region, where the measurement data are exceptionally robust against noise corruption. The disturbances are further suppressed by applying a specially designed adaptive bilateral impedance filter (ABIF), which considers signal power content and impedance measurements' distribution enabling a nearly unbiased result. The feasibility of the proposed HPRS signal is verified experimentally by comparing it with the typical PRS signal and step signal. The results suggest superior broadband impedance measurements' accuracy and robustness under different ambient temperatures and state of charges (SOCs), and the maximum normalized root-mean-square error (NRMSE) is limited to 0.77%.
27 October 2022 in IEEE Transactions on Industrial Informatics
Electrochemical impedance spectroscopy (EIS) can provide fruitful information for Lithium-ion (Li-ion) battery modeling and diagnosis, yet EIS measurement is time-consuming with low-frequency signal injection. By stacking a group of broadband signals, pseudorandom sequence (PRS) makes it possible to obtain the battery EIS in a few seconds at the expense of measurement accuracy and signal-to-noise ratio (SNR). Thus, this article focuses on developing a highly effective signal processing procedure to extract useful information from the PRS for accurate EIS measurement. To enhance the ability of the data cleaning procedure, a three-dimensional cloud is first reconstructed for each impedance by integrating its power spectrum (PS). The impedance with lower PS can be easily removed through a statistical based multiple selection mechanism, which enables the extraction of the EIS without altering the original measurement. Experimental results on a 3000 mAh Li-ion battery prove the effectiveness of the proposed method.
9 January 2023 in IEEE Transactions on Industrial Electronics
Online battery impedance acquisition is of increasing interest due to its valuable information for state estimation and fault diagnosis. The pseudorandom sequence (PRS) can significantly mitigate the required time cost, yet suffers from an insufficient signal-to-noise ratio. Motivated by this, this article proposes a novel series-connected dual pseudorandom sequence for enhancing the signal power content in all frequency ranges, which notably improves the robustness of broadband impedance acquisition against interference. A weighted bilateral impedance filter is further carried out on a semilogarithm scale to process the measurement data, which effectively compensates for the noise-induced biases and enables a nearly unbiased result. Experimental studies verify the proposed framework by comparing it with the conventional PRS method in terms of accuracy and robustness under various states of charges, ambient temperatures, and aging status of the batteries.