Michele Spinelli

Michele Spinelli

Auto-generated profile, based on publicly available information

Michele Spinelli

Laboratorio di Tecnologia Medica, Istituto Ortopedico Rizzoli, Bologna, Italy

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2008 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Saverio AffatatoSaverio Affatato
Saverio Affatato
MSM. Spinelli
M. Spinelli
MZM. Zavalloni
M. Zavalloni
CMC. Mazzega-Fabbro
C. Mazzega-Fabbro
Marco VicecontiMarco Viceconti
Marco Viceconti
Interest in the rheology and effects of interacting surfaces is as ancient as man. This subject can be represented by a recently coined word: tribology. This term is derived from the Greek word "tribos" and means the "science of rubbing". Friction, lubrication, and wear mechanism in the common English language means the precise field of interest of tribology. Wear of total hip prosthesis is a significant clinical problem that involves, nowadays, a too high a number of patients. In order to acquire further knowledge on the tribological phenomena that involve hip prosthesis wear tests are conducted on employed materials to extend lifetime of orthopaedic implants. The most basic type of test device is the material wear machine, however, a more advanced one may more accurately reproduce some of the in vivo conditions. Typically, these apparatus are called simulators, and, while there is no absolute definition of a joint simulator, its description as a mechanical rig used to test a joint replacement, under conditions approximating those occurring in the human body, is acceptable. Simulator tests, moreover, can be used to conduct accelerated protocols that replicate/simulate particularly extreme conditions, thus establishing the limits of performance for the material. Simulators vary in their level of sophistication and the international literature reveals many interpretations of the design of machines used for joint replacement testing. This paper aims to review the current state of the art of the hip joint simulators worldwide. This is specified through a schematic overview by describing, in particular, constructive solutions adopted to reproduce in vivo conditions. An exhaustive commentary on the evolution and actually existing simulation standards is proposed by the authors. The need of a shared protocol among research laboratories all over the world could lead to a consensus conference.


1 November 2009 in Journal of Biomechanics
Verified
Journal Article
Closed access
Saverio AffatatoSaverio Affatato
Saverio Affatato
MSMichele Spinelli
Michele Spinelli
SSStefano Squarzoni
Stefano Squarzoni
FTFrancesco Traina
Francesco Traina
ATAldo Toni
Aldo Toni

13 April 2010 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
Saverio AffatatoSaverio Affatato
Saverio Affatato
MSMichele Spinelli
Michele Spinelli
MZMara Zavalloni
Mara Zavalloni
FTFrancesco Traina
Francesco Traina
SCSimone Carmignato
Simone Carmignato
ATAldo Toni
Aldo Toni

1 October 2009 in Clinical Biomechanics
Verified
Journal Article
Closed access
Saverio AffatatoSaverio Affatato
Saverio Affatato
Paola TaddeiPaola Taddei
Paola Taddei
Alberto LeardiniAlberto Leardini
Alberto Leardini
SGS. Giannini
S. Giannini
MSM. Spinelli
M. Spinelli
Marco VicecontiMarco Viceconti
Marco Viceconti