Damian Siedlecki

Damian Siedlecki

Auto-generated profile, based on publicly available information

Damian Siedlecki

Institute of Physics, Wroclaw University of Technology, Wroclaw, Poland

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
SOSergio Ortiz
Sergio Ortiz
DSDamian Siedlecki
Damian Siedlecki
IGIreneusz Grulkowski
Ireneusz Grulkowski
LRLaura Remon
Laura Remon
DPDaniel Pascual
Daniel Pascual
SMSusana Marcos
Susana Marcos
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

30 September 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
ACAlberto De Castro
Alberto De Castro
SOSergio Ortiz
Sergio Ortiz
EGEnrique Gambra
Enrique Gambra
DSDamian Siedlecki
Damian Siedlecki
SMSusana Marcos
Susana Marcos
We present an optimization method to retrieve the gradient index (GRIN) distribution of the in-vitro crystalline lens from optical path difference data extracted from OCT images. Three-dimensional OCT images of the crystalline lens are obtained in two orientations (with the anterior surface up and posterior surface up), allowing to obtain the lens geometry. The GRIN reconstruction method is based on a genetic algorithm that searches for the parameters of a 4-variable GRIN model that best fits the distorted posterior surface of the lens. Computer simulations showed that, for noise of 5 μm in the surface elevations, the GRIN is recovered with an accuracy of 0.003 and 0.010 in the refractive indices of the nucleus and surface of the lens, respectively. The method was applied to retrieve three-dimensionally the GRIN of a porcine crystalline lens in vitro. We found a refractive index ranging from 1.362 in the surface to 1.443 in the nucleus of the lens, an axial exponential decay of the GRIN profile of 2.62 and a meridional exponential decay ranging from 3.56 to 5.18. The effect of GRIN on the aberrations of the lens also studied. The estimated spherical aberration of the measured porcine lens was 2.87 μm assuming a homogenous equivalent refractive index, and the presence of GRIN shifted the spherical aberration toward negative values (−0.97 μm), for a 6-mm pupil.

2 December 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
SOSergio Ortiz
Sergio Ortiz
DSDamian Siedlecki
Damian Siedlecki
LRLaura Remon
Laura Remon
SMSusana Marcos
Susana Marcos
We address the measurement and correction of fan distortion in optical coherence tomography (OCT). This effect arises from the scanning system configuration and prevents one, in general, from obtaining quantitative topographic data from OCT. Computer simulations allowed us to quantify the effect and evaluate its dependence on the scanning mirror separation and design of the collimating lens, as well as to estimate the optimal axial position of that lens to minimize the fan distortion. We also developed a numerical algorithm based on 3-D ray propagation for the correction of the residual fan distortion. The effect was studied experimentally using a custom developed time-domain OCT in a Michelson configuration provided with a confocal channel, and the accuracy of the fan distortion correction algorithm tested on samples of known dimensions (flat surfaces and spherical lenses). With a proper calibration of the system with use of an onfocal channel, this algorithm makes it possible for time-domain OCT devices to be used as topographers.

4 November 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SOSergio Ortiz
Sergio Ortiz
DSDamian Siedlecki
Damian Siedlecki
PPPablo Pérez-Merino
Pablo Pérez-Merino
NCNoelia Chia
Noelia Chia
ACAlberto de Castro
Alberto de Castro
SMSusana Marcos
Susana Marcos
We present a method to obtain accurate corneal topography from a spectral optical coherence tomography (sOCT) system. The method includes calibration of the device, compensation of the fan (or field) distortion introduced by the scanning architecture, and image processing analysis for volumetric data extraction, segmentation and fitting. We present examples of three-dimensional (3-D) surface topography measurements on spherical and aspheric lenses, as well as on 10 human corneas in vivo. Results of sOCT surface topography (with and without fan-distortion correction) were compared with non-contact profilometry (taken as reference) on a spherical lens, and with non-contact profilometry and state-of-the art commercial corneal topography instruments on aspheric lenses and on subjects. Corneal elevation maps from all instruments were fitted by quadric surfaces (as well as by tenth-order Zernike polynomials) using custom routines. We found that the discrepancy in the estimated radius of curvature from nominal values in artificial corneas decreased from 4.6% (without fan distortion correction) to 1.6% (after fan distortion correction), and the difference in the asphericity decreased from 130% to 5%. In human corneas, the estimated corneal radius of curvature was not statistically significantly different across instruments. However, a Bland-Altman analysis showed consistent differences in the estimated asphericity and corneal shape between sOCT topographies without fan distortion correction and the rest of the measurements.

1 June 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DSDamian Siedlecki
Damian Siedlecki
HKHenryk Kasprzak
Henryk Kasprzak
BPBarbara K. Pierscionek
Barbara K. Pierscionek
A new schematic eye with aspheric surfaces and a radially varying refractive-index distribution lens is proposed. Image quality and spherical aberration are determined by use of ray tracing, and the results are presented as spot diagrams and compared with five existing model eyes. The proposed model provides the best image quality and lowest spherical aberration.

8 November 2010 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DBDavid Borja
David Borja
DSDamian Siedlecki
Damian Siedlecki
ACAlberto De Castro
Alberto De Castro
SUStephen Uhlhorn
Stephen Uhlhorn
SOSergio Ortiz
Sergio Ortiz
FMFabrice Manns
Fabrice Manns
We quantify the posterior surface distortions in optical coherence tomography (OCT) images of isolated crystalline lenses. The posterior radius of curvature and asphericity obtained from OCT images acquired with the beam incident first on the anterior, and then the posterior, surface were compared. The results were compared with predictions of a ray-tracing model which includes the index gradient. The results show that the error in the radius of curvature is within the measurement reproducibility and that it can be corrected by assuming a uniform refractive index. However, accurate asphericity values require a correction algorithm that takes into account the gradient.