Fanqin Ding

Fanqin Ding

Auto-generated profile, based on publicly available information

Fanqin Ding

Key Laboratory of Power Electronics for Energy Conservation and Motor Drive of Hebei Province, Department of Electrical Engineering, Yanshan University, Qinhuangdao, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2024 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XGXiaoqiang Guo
Xiaoqiang Guo
Shiqi ZhangShiqi Zhang
Shiqi Zhang
FDFanqin Ding
Fanqin Ding
JZJie Zhu
Jie Zhu
HBHaoyu Bai
Haoyu Bai
Electrolyzers are widely used in renewable energy hydrogen production, and the performance of electrolyzers is directly related to dc–dc converters. To realize the high-efficiency operation of the electrolyzer, new challenges, such as a high step-down ratio and low output current ripple, are put forward for the dc–dc converter. In this article, we propose a novel type of dc–dc converter for hydrogen production. The topology is simple and has the advantages of higher step-down gain and low switching stress. In addition, the scheme can achieve ultralow output current ripple without active devices. Finally, the topology connects the electrolyzer hydrogen production load in the experiment to verify the scheme's effectiveness.

18 March 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Shiqi ZhangShiqi Zhang
Shiqi Zhang
YTYiyina Teng
Yiyina Teng
YSYuhang Sun
Yuhang Sun
FDFanqin Ding
Fanqin Ding
NWNing Wang
Ning Wang
CHChangchun Hua
Changchun Hua
The multi-port converter offers significant advantages in sustainable energy-based hydrogen production, such as high energy density and wide application potential. As the core energy hub in these systems, the multi-port hydrogen converter demands high reliability. However, its numerous switches and complex operation increase the risk of failure. Currently, there are no effective fault diagnosis or fault tolerance solutions for these systems. Current fault diagnosis methods for two-port and multi-port converters rely on many sensors, have low accuracy, and cannot handle multi-switch faults. Additionally, existing fault tolerance strategies fall short of maintaining stable power for the electrolyzer and don't allow capacity sharing among ports. This paper proposes a fault diagnosis method for open-circuit faults in a triple-port hydrogen converter and a corresponding fault-tolerant operating strategy. By optimizing a random forest algorithm with a sparrow search algorithm, high-precision multi-switch fault diagnosis is achieved using only three current sensors. Fault-tolerant operation of the system is ensured through an auxiliary switch following a failure. Additionally, power sharing between output ports can be realized. This ensures the efficient and stable operation of the hydrogen production system. The effectiveness of this solution has been validated through simulations and experiments.