Kangping Hu

Kangping Hu

Auto-generated profile, based on publicly available information

Kangping Hu

School of Engineering, Brown University, Providence, RI, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2021 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
KHKangping Hu
Kangping Hu
CAChristopher E. Arcadia
Christopher E. Arcadia
JRJacob K. Rosenstein
Jacob K. Rosenstein
This letter presents a large-scale fully integrated multimodal sensor array for biological imaging. The 512×256 sensor array can perform spatially resolved electrochemical impedance spectroscopy (EIS) with switching frequencies up to 100 MHz, acquire multicolor optical images, and sense pH using titanium nitride (TiN) ion sensitive field effect transistors (ISFETs). The chip features code-division multiplexed (CDM) readout of groups of pixels simultaneously, enabling extended integration times at a given frame rate. The system is implemented in 180-nm CMOS with 9.5 μm × 11.5 μm pixels. Its overall fill factor is 57%, including peripheral control and readout circuits, yielding a widefield spatially resolved multimodal biosensing platform for advanced cell culture applications.

16 June 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
KHKangping Hu
Kangping Hu
JHJason Ho
Jason Ho
JRJacob K. Rosenstein
Jacob K. Rosenstein
Super-resolution imaging is a family of techniques in which multiple lower-resolution images can be merged to produce a single image at higher resolution. While super-resolution is often applied to optical systems, it can also be used with other imaging modalities. Here we demonstrate a 512 × 256 CMOS sensor array for micro-scale super-resolution electrochemical impedance spectroscopy (SR-EIS) imaging. The system is implemented in standard 180 nm CMOS technology with a 10 $\mu$ m × 10 $\mu$ m pixel size. The sensor array is designed to measure the mutual capacitance between programmable sets of pixel pairs. Multiple spatially-resolved impedance images can then be computationally combined to generate a super-resolution impedance image. We use finite-element electrostatic simulations to support the proposed measurement approach and discuss straightforward algorithms for super-resolution image reconstruction. We present experimental measurements of sub-cellular permittivity distribution within single green algae cells, showing the sensor’s capability to produce microscale impedance images with sub-pixel resolution.

17 June 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
MAManar Abdelatty
Manar Abdelatty
JIJoseph Incandela
Joseph Incandela
KHKangping Hu
Kangping Hu
PJPushkaraj Joshi
Pushkaraj Joshi
JLJoseph W. Larkin
Joseph W. Larkin
JRJacob K. Rosenstein
Jacob K. Rosenstein
Electrical capacitance tomography (ECT) can be used to predict information about the interior volume of an object based on measured capacitance at its boundaries. Here, we present a microscale capacitance tomography system with a spatial resolution of 10 microns using an active CMOS microelectrode array. We introduce a deep learning model for reconstructing 3-D volumes of cell cultures using the boundary capacitance measurements acquired from the sensor array, which is trained using a multi-objective loss function that combines a pixel-wise loss function, a distribution-based loss function, and a region-based loss function to improve model's reconstruction accuracy. The multi-objective loss function enhances the model's reconstruction accuracy by 3.2% compared to training only with a pixel-wise loss function. Compared to baseline computational methods, our model achieves an average of 4.6% improvement on the datasets evaluated. We demonstrate our approach on experimental datasets of bacterial biofilms, showcasing the system's ability to resolve microscopic spatial features of cell cultures in three dimensions. Microscale capacitance tomography can be a low-cost, low-power, label-free tool for 3-D imaging of biological samples.

14 August 2024 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
XLXiaoyu Lian
Xiaoyu Lian
ESEric Stang
Eric Stang
KHKangping Hu
Kangping Hu
PGPradeep R. Guduru
Pradeep R. Guduru
JRJacob K. Rosenstein
Jacob K. Rosenstein
This letter presents a high-speed global-shutter thermal imaging system, with a 24V×24H pixel HgCdTe infrared focal plane array (FPA) detector and a custom CMOS readout integrated circuit (ROIC) including a 768-frame on-chip analog burst memory bank. Each pixel contains a buffered current injection circuit and a background current reduction circuit. The system is designed for cryogenic operation at liquid nitrogen temperatures, and it achieves a maximum burst-mode frame rate of 5 million frames per second, which is the fastest demonstrated imaging array for mid/long-wavelength infrared.

10 February 2023 in Biophysical Journal
Verified
Journal Article
Closed access
PDF file
JRJacob K. Rosenstein
Jacob K. Rosenstein
KHKangping Hu
Kangping Hu
PJPushkaraj Joshi
Pushkaraj Joshi
JIJoseph T. Incandela
Joseph T. Incandela
JLJoseph Larkin
Joseph Larkin

25 September 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
JIJoseph T. Incandela
Joseph T. Incandela
KHKangping Hu
Kangping Hu
PJPushkaraj Joshi
Pushkaraj Joshi
JRJacob K. Rosenstein
Jacob K. Rosenstein
JLJoseph W. Larkin
Joseph W. Larkin
Many fundamental insights into microbiology have come from imaging, which is typically synonymous with optical techniques. However, the sample preparation needed for many optical microscopy methods such as labeling, fixing, or genetic modification, limits the range of species and environments we can investigate. Here we demonstrate the use of electrical capacitance measurements as a non-optical method for imaging live microbial samples. In electrical capacitance imaging (ECI), samples are positioned in contact with a semiconductor sensor array, and localized capacitance measurements are made across the array. From these measurements, we generate textured images of a variety of microbial colonies. We determine that capacitance is correlated with local sample thickness by comparing ECI data to 3D confocal scans. We further illustrate with ECI that a difference in capacitance signal allows microbial species to be spatially distinguished in co-culture conditions. In order to highlight the versatility of our system, we capture the cross-sectional development of floating pellicle biofilms in a liquid culture at millimeter length scales during weeks-long time-lapse experiments. These novel results establish a new low-cost and portable platform which can be used for spatially and temporally resolved experiments in diverse environments with a wide variety of microbial species. IMPORTANCE Microbes live in diverse environments, and occupy biological roles across many timescales. Investigating the full scope of microbial activity requires imaging systems appropriate to each context. Though optical microscopy is powerful, the use of light, lenses, and other hardware limits where it can be applied. At the same time, existing non-optical imaging methods are frequently destructive to samples and require extensive equipment. In this paper we present a non-optical imaging system that is small, cheap, requires no sample labeling, and is compatible with a variety of microbial species. Our system uses semiconductor chips to measure the inherent material properties of a sample with spatial sensitivity, producing images of microbes contrasted against their environment and each other. Our technique captures label-free, micrometer-resolution images with a pocket-sized device, enabling microbiological imaging experiments in new environments with new species.