Antoine Simon

Antoine Simon

Auto-generated profile, based on publicly available information

Antoine Simon

LTSI, Universite de Rennes 1, Bât. 22, Campus de Beaulieu, Rennes, 35065, FRANCE

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JCJoel Castelli
Joel Castelli
ASAntoine Simon
Antoine Simon
GLGuillaume Louvel
Guillaume Louvel
OHOlivier Henry
Olivier Henry
ECEnrique Chajon
Enrique Chajon
RCRenaud de Crevoisier
Renaud de Crevoisier
Large anatomical variations occur during the course of intensity-modulated radiation therapy (IMRT) for locally advanced head and neck cancer (LAHNC). The risks are therefore a parotid glands (PG) overdose and a xerostomia increase. The purposes of the study were to estimate: - the PG overdose and the xerostomia risk increase during a “standard” IMRT (IMRTstd); - the benefits of an adaptive IMRT (ART) with weekly replanning to spare the PGs and limit the risk of xerostomia. Fifteen patients received radical IMRT (70 Gy) for LAHNC. Weekly CTs were used to estimate the dose distributions delivered during the treatment, corresponding either to the initial planning (IMRTstd) or to weekly replanning (ART). PGs dose were recalculated at the fraction, from the weekly CTs. PG cumulated doses were then estimated using deformable image registration. The following PG doses were compared: pre-treatment planned dose, per-treatment IMRTstd and ART. The corresponding estimated risks of xerostomia were also compared. Correlations between anatomical markers and dose differences were searched. Compared to the initial planning, a PG overdose was observed during IMRTstd for 59% of the PGs, with an average increase of 3.7 Gy (10.0 Gy maximum) for the mean dose, and of 8.2% (23.9% maximum) for the risk of xerostomia. Compared to the initial planning, weekly replanning reduced the PG mean dose for all the patients (p < 0.05). In the overirradiated PG group, weekly replanning reduced the mean dose by 5.1 Gy (12.2 Gy maximum) and the absolute risk of xerostomia by 11% (p < 0.01) (30% maximum). The PG overdose and the dosimetric benefit of replanning increased with the tumor shrinkage and the neck thickness reduction (p < 0.001). During the course of LAHNC IMRT, around 60% of the PGs are overdosed of 4 Gy. Weekly replanning decreased the PG mean dose by 5 Gy, and therefore by 11% the xerostomia risk.

26 March 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
OAOscar Acosta
Oscar Acosta
GDGael Drean
Gael Drean
JOJuan D Ospina
Juan D Ospina
ASAntoine Simon
Antoine Simon
PHPascal Haigron
Pascal Haigron
RCRenaud de Crevoisier
Renaud de Crevoisier
The majority of current models utilized for predicting toxicity in prostate cancer radiotherapy are based on dose-volume histograms. One of their main drawbacks is the lack of spatial accuracy, since they consider the organs as a whole volume and thus ignore the heterogeneous intra-organ radio-sensitivity. In this paper, we propose a dose-image-based framework to reveal the relationships between local dose and toxicity. In this approach, the three-dimensional (3D) planned dose distributions across a population are non-rigidly registered into a common coordinate system and compared at a voxel level, therefore enabling the identification of 3D anatomical patterns, which may be responsible for toxicity, at least to some extent. Additionally, different metrics were employed in order to assess the quality of the dose mapping. The value of this approach was demonstrated by prospectively analyzing rectal bleeding (≥Grade 1 at 2 years) according to the CTCAE v3.0 classification in a series of 105 patients receiving 80 Gy to the prostate by intensity modulated radiation therapy (IMRT). Within the patients presenting bleeding, a significant dose excess (6 Gy on average, p < 0.01) was found in a region of the anterior rectal wall. This region, close to the prostate (1 cm), represented less than 10% of the rectum. This promising voxel-wise approach allowed subregions to be defined within the organ that may be involved in toxicity and, as such, must be considered during the inverse IMRT planning step.

1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
BRBastien Rigaud
Bastien Rigaud
ASAntoine Simon
Antoine Simon
JCJoël Castelli
Joël Castelli
MGMaxime Gobeli
Maxime Gobeli
JAJuan-David Ospina Arango
Juan-David Ospina Arango
RCRenaud De Crevoisier
Renaud De Crevoisier
In the context of head and neck cancer (HNC) adaptive radiation therapy (ART), the two purposes of the study were to compare the performance of multiple deformable image registration (DIR) methods and to quantify their impact for dose accumulation, in healthy structures. Fifteen HNC patients had a planning computed tomography (CT0) and weekly CTs during the 7 weeks of intensity-modulated radiation therapy (IMRT). Ten DIR approaches using different registration methods (demons or B-spline free form deformation (FFD)), preprocessing, and similarity metrics were tested. Two observers identified 14 landmarks (LM) on each CT-scan to compute LM registration error. The cumulated doses estimated by each method were compared. The two most effective DIR methods were the demons and the FFD, with both the mutual information (MI) metric and the filtered CTs. The corresponding LM registration accuracy (precision) was 2.44 mm (1.30 mm) and 2.54 mm (1.33 mm), respectively. The corresponding LM estimated cumulated dose accuracy (dose precision) was 0.85 Gy (0.93 Gy) and 0.88 Gy (0.95 Gy), respectively. The mean uncertainty (difference between maximal and minimal dose considering all the 10 methods) to estimate the cumulated mean dose to the parotid gland (PG) was 4.03 Gy (SD = 2.27 Gy, range: 1.06–8.91 Gy).

1 August 2014 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JOJuan D. Ospina
Juan D. Ospina
JZJian Zhu
Jian Zhu
CCCiprian Chira
Ciprian Chira
ABAlberto Bossi
Alberto Bossi
JDJean B. Delobel
Jean B. Delobel
RCRenaud de Crevoisier
Renaud de Crevoisier

5 March 2014 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
FMFabio Martínez
Fabio Martínez
EREduardo Romero
Eduardo Romero
GDGaël Dréan
Gaël Dréan
ASAntoine Simon
Antoine Simon
PHPascal Haigron
Pascal Haigron
OAOscar Acosta
Oscar Acosta
Accurate segmentation of the prostate and organs at risk in computed tomography (CT) images is a crucial step for radiotherapy planning. Manual segmentation, as performed nowadays, is a time consuming process and prone to errors due to the a high intra- and inter-expert variability. This paper introduces a new automatic method for prostate, rectum and bladder segmentation in planning CT using a geometrical shape model under a Bayesian framework. A set of prior organ shapes are first built by applying principal component analysis to a population of manually delineated CT images. Then, for a given individual, the most similar shape is obtained by mapping a set of multi-scale edge observations to the space of organs with a customized likelihood function. Finally, the selected shape is locally deformed to adjust the edges of each organ. Experiments were performed with real data from a population of 116 patients treated for prostate cancer. The data set was split in training and test groups, with 30 and 86 patients, respectively. Results show that the method produces competitive segmentations w.r.t standard methods (averaged dice = 0.91 for prostate, 0.94 for bladder, 0.89 for rectum) and outperforms the majority-vote multi-atlas approaches (using rigid registration, free-form deformation and the demons algorithm).

16 August 2018 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
BRBastien Rigaud
Bastien Rigaud
ASAntoine Simon
Antoine Simon
MGMaxime Gobeli
Maxime Gobeli
JLJulie Leseur
Julie Leseur
LDLoig Duverge
Loig Duverge
RCRenaud De Crevoisier
Renaud De Crevoisier
External beam radiotherapy is extensively used to treat cervical carcinomas. A single planning CT scan enables the calculation of the dose distribution. The treatment is delivered over 5 weeks. Large per-treatment anatomical variations may hamper the dose delivery, with the potential of an organs at risk (OAR) overdose and a tumor underdose. To anticipate these deformations, a recent approach proposed three planning CTs with variable bladder volumes, which had the limitation of not covering all per-treatment anatomical variations. An original patient-specific population-based library has been proposed. It consisted of generating two representative anatomies, in addition to the standard planning CT anatomy. First, the cervix and bladder meshes of a population of 20 patients (314 images) were registered to an anatomical template, using a deformable mesh registration. An iterative point-matching algorithm was developed based on local shape context (histogram of polar or cylindrical coordinates and geodesic distance to the base) and on a topology constraint filter. Second, a standard principal component analysis (PCA) model of the cervix and bladder was generated to extract the dominant deformation modes. Finally, specific deformations were obtained using posterior PCA models, with a constraint representing the top of the uterus deformation. For a new patient, the cervix-uterus and bladder were registered to the template, and the patient’s modeled planning library was built according to the model deformations. This method was applied following a leave-one-patient-out cross-validation. The performances of the modeled library were compared to those of the three-CT-based library and showing an improvement in both target coverage and OAR sparing.