Thomas Robert Doebbert

Thomas Robert Doebbert

Auto-generated profile, based on publicly available information

Thomas Robert Doebbert

Electrical Measurement Engineering Helmut-Schmidt-University Hamburg Germany

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2021 in IEEE Access
Verified
Journal Article
Open access
TDThomas R. Doebbert
Thomas R. Doebbert
CCChristoph Cammin
Christoph Cammin
GSGerd Scholl
Gerd Scholl
In the field of production automation, IO-Link Wireless (IOLW) offers energy-efficient and cost-effective solutions for networking wireless sensors and actuators close to the machines on the industrial shop-floor. In this paper, a concept is presented to enhance IOLW with security-for-safety and safety features in order to make safety critical systems in industrial environments with performance characteristics dedicated to demanding applications feasible. As data security is of paramount importance, security mechanisms already implemented in other wireless protocols are investigated and security-for-safety mechanisms for IOLW are introduced. Potential cryptographic algorithms are evaluated for IOLW with respect to energy consumption and timing. Taking performance parameters into account, which are crucial for industrial manufacturing processes, a safety protocol data unit (SPDU) is described and evaluated for different payload length and cycle times. Finally, an outlook towards the implementation of a demonstrator setup completes this work.

7 September 2021
Verified
Conference Paper
Closed access
TDThomas Robert Doebbert
Thomas Robert Doebbert
CCChristoph Cammin
Christoph Cammin
GSGerd Scholl
Gerd Scholl
BKBernd Karcher
Bernd Karcher
Wireless networks support highly flexible manufacturing processes and are recognized as a crucial pillar towards the digitization of industrial production (automation). While 5G is currently being marketed as universal solution for future wireless communication, high density of sensor and actuator nodes in industrial manufacturing environments with respect to latency times and reliability, still represents an enormous technical challenge. In the field of production automation standards, IO-Link Wireless (IOLW) is already in operation offering energy-efficient and cost-effective solutions, even with battery-powered smart sensor devices. In this paper, the deterministic ultra-reliable low-latency communication (URLLC) features of 5G are combined with the outstanding performance characteristics of IOLW with respect to robustness and latency to realize even highly demanding safety applications in industrial environments.

10 September 2024
Verified
Conference Paper
Closed access
HBHenry Beuster
Henry Beuster
KTKevin Tebbe
Kevin Tebbe
TDThomas Robert Doebbert
Thomas Robert Doebbert
GSGerd Scholl
Gerd Scholl
In the past few years, there has been a growing sig-nificance of interactions between human workers and automated systems throughout the factory floor. Wherever static or mobile robots, such as automated guided vehicles, operate autonomously, a protected environment for personnel and machines must be provided by, e.g., safe, deterministic and low-latency technologies. Another trend in this area is the increased use of wireless communication, offering a high flexibility, modularity, and reduced installation and maintenance efforts. This work presents a testbed implementation that integrates a wireless framework, employing IO-Link Wireless (IOLW) and a private 5G cellular network, to orchestrate a complete example process from sensors and actuators up into the edge, represented by a programmable logic controller (PLC). Latency assessments identify the system's cycle time as well as opportunities for improvement. A worst-case estimation shows the attainable safety function response time for practical applications in the context of functional safety.

13 June 2022 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
TDThomas Robert Doebbert
Thomas Robert Doebbert
CCChristoph Cammin
Christoph Cammin
GSGerd Scholl
Gerd Scholl
Modern production concepts generate a demand for reliable, energy-efficient, fast, and secure wireless communication solutions. Therefore, the current consumption should not increase substantially due to additional cryptographic operations. This paper shows a principle current measurement method that is exemplary of a transceiver for the IO-Link Wireless protocol. Low-pass filtering and single-sided amplitude spectrum analysis are used to evaluate the main information of the current measurement. An uncertainty estimation is realized using statistical measurement data and considering the measurement setup in order to approximate the combined standard uncertainty. The results show that the current consumption only increases slightly when using additional cryptographic operations. This can be measured with acceptable uncertainty.

13 October 2025
Verified
Conference Paper
Open access
FFFlorian Foerster
Florian Foerster
SHSong Son Ha
Song Son Ha
HBHenry Beuster
Henry Beuster
TDThomas Robert Doebbert
Thomas Robert Doebbert
GSGerd Scholl
Gerd Scholl
DMDominik Merli
Dominik Merli

23 May 2024 in arXiv
Verified
Preprint
Open access
PDF file
HBHenry Beuster
Henry Beuster
TDThomas Doebbert
Thomas Doebbert
CCChristoph Cammin
Christoph Cammin
DKDmytro Krush
Dmytro Krush
GSGerd Scholl
Gerd Scholl
Modern manufacturing is characterized by a high degree of automation, with autonomous systems also frequently being used. In such environments human intervention in the event of malfunctions or maintenance becomes a rare but also necessary task. When human workers are no longer an integral part of the production process, but only intervene when necessary, e.g., in the case of unexpected machine behavior, appropriate safety solutions will become even more important. This work describes a wireless communication system enabling a flexible and safe emergency stop function for multiple automation cells. A portable emergency stop switch allows seamless transition between different wireless cells, ensuring functional safety. The communication protocol combines IO-Link Wireless features with the safety requirements already implemented in IO-Link Safety. Security requirements are fulfilled through encryption and authentication. The IO-Link Wireless roaming functionality is used to extend the system across several manufacturing cells. An experimental setup confirms the suitability of the system for various applications. The results demonstrate the effectiveness of the handover mechanism and evaluate the potential of the system to improve flexibility, availability and security in dynamic production environments. Future extensions could include the use of AI based evaluation of the radio signals for an intelligent cell handover.