31 August 2024 in Noise & Vibration Worldwide
With the developing technology and mechanization, the number of industrial facilities has increased. It is important for the worker’s physical and mental health to be in suitable working conditions. This paper analyses the regulations applied in the examination and evaluation of the acoustic environment in industrial facilities. The European Parliament and Council Directive, the United States, Singapore, Canada, Australia, Mexico, Japan, and WHO principles were analysed in detail. Simultaneously, analyses were conducted on the auditory perception of the workers in industrial facilities. As a result of the study, 85, 87, and 90 dBA noise exposure levels were determined for 8 h in different regulations examined. It has been determined that the regulative systems for the auditory perception of the workers in industrial facilities are insufficient. It was found necessary to develop regulation systems for evaluating noise exposure levels and the auditory perception of the workers together. It is important for the occupational health and safety of workers to develop a holistic approach in the update and revision of international regulation and to evaluate the control mechanisms within this scope. The protection of mental and physical health of the workers is presented as the most fundamental requirement. Moreover, it should be ensured that the noise control measures that can be taken (at the source, at the transmission path, and at the receiver) are formed by reducing the noise exposure and increasing the auditory perception of the workers in a positive view.
2 September 2021 in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
Konuşma eyleminin bulunduğu hacimlerde, akustik performansın oluşturulmasında öznel ve nesnel hacim akustik parametreleri ele alınmalıdır. Bu çalışmada; mevcut durumda bulunan Irak-Necef İslam Üniversitesi Alawiya Konferans Salonu’nun konuşma eylemine yönelik akustik performans değerlendirmesi yapılmıştır. Çalışma kapsamında, hacim akustiği çerçevesinde öznel ve nesnel parametreleri etkileyen reverberasyon süresinin kontrolü üzerinde durulmuş, hacim içi reverberasyon süresi ve hacmin yüzey yutuculuklarının ilişkisi incelenmiştir. Mevcut durumda yerinde ölçümler yapılarak reverberasyon süresi tespit edilmiştir. Salonun reverberasyon süresinin düşürülmesine yönelik; ses yutuculuk katsayılarına göre seçilen malzemeler, farklı konumlandırılarak modeller geliştirilmiştir. Akustik analiz için kullanılan ECOTECT v.5.20 bilgisayar simülasyon programı aracılığıyla geliştirilen modellerin reverberasyon süreleri belirlenmiş ve ışın izleme yöntemi ile geometrik analizleri yapılmıştır. Modellerin karşılaştırılması ile hacim içi konuşma eylemine yönelik uygun reverberasyon süresinin elde edilmesinde yüzey yutuculukları analiz edilmiştir. Çalışmanın sonucunda konuşma eylemine yönelik kare planlı, düz zeminli ve yüksek tavanlı (en az 6 m) hacim içerisinde akustik iyileştirme kapsamında; duvar, tavan ve döşeme bitiş malzeme konumlarının ve yüzey yutuculuklarının reverberasyon süresine etkisi değerlendirilmiştir.
30 September 2025 in Budownictwo i Architektura
Structural fires have long posed significant threats to human life, property, and societal stability. In the context of historic buildings, fires also risk the loss of irreplaceable cultural heritage. Ensuring fire safety in such structures requires a sensitive balance between risk mitigation and architectural conservation. This study investigates fire safety strategies in historic buildings through the restoration and renovation project of Bıçakçı Khan and Yıldız Cinema, two culturally significant structures in İzmir, Türkiye. Using Türkiye's Regulation on Fire Protection (TRFP) as the main guideline, a systematic fire safety control method was implemented through regulatory compliance checks, occupant load calculations, qualitative risk assessments (QRA), and evacuation route evaluations. The systematic fire safety control method adopts a two-step approach, in which the first step involves analysing occupant loads and architectural egress provisions, and the second step consists of conducting a qualitative risk analysis based on regulatory compliance. The study reveals that current fire safety regulations, while generally applicable, fall short in addressing the specific vulnerabilities of heritage structures. By applying a qualitative risk analysis, the research identifies the need for tailored strategies that prioritise both occupant safety and the preservation of architectural authenticity. Passive protection measures and low-impact interventions are proposed as effective means to enhance fire resilience in historic buildings. In conclusion, a systematic fire safety control method is proposed, emphasising minimal architectural intervention and the preservation of historical integrity. The study concludes with recommendations for revising current regulations and adopting performance-based approaches that integrate architectural, engineering, and conservation expertise, thereby ensuring both safety and cultural continuity.
11 October 2023 in Periodica Polytechnica Architecture
Light pipes are innovative daylight lighting systems often used linearly which transmit light through reflections on carrying surfaces. However, in order for the system to be used in more complex buildings, it should be possible to integrate one or more elbows into the system if needed with the purpose of deliberately change the direction of light transmission. In this study, attention is drawn to the assumption that the light carried in the elbowed light pipes is related to the design of the elbow geometry as well as variables such as pipe length, diameter (aspect ratio), reflectance and transmittance values of the components, sky conditions, solar angles, latitude-longitude data, elbow angle, etc. The purpose of the study is to investigate the daylight performance of elbowed light pipe system and different elbow geometries. In this respect, the models used in scientific studies and commercial products were compared and new elbow models were proposed. Daylight levels (lux) and Daylight Factor (DF) achieved through a numerical simulation software based on a correct method and well-established algorithm were evaluated as performance measures. Whether the light levels reached as a result of the analyses alone are sufficient to illuminate the space varies depending on the dimensions, function and duration of use of the space.
12 September 2022 in Periodica Polytechnica Architecture
There are subjective and objective acoustic parameters in the creation of acoustic performance for speech action in room acoustics. Control of reverberation time affecting subjective and objective acoustic parameters is a main parameter in room acoustics. In this study, the acoustic performance assessment of the TOBB Twins Headquarters Reception Hall, which is current enclosed space with square plan and flat floor, has been performed as a case study. The evaluation focused on the relationship between reverberation time and interior surface absorption. Primarily, the reverberation time was determined according to the international standard with in-situ measurements in the current enclosed space. The reverberation time of the space was found over the reference value range. Models have been developed with the use of materials to reduce the reverberation time. In the assessment of room acoustics parameters, reverberation times of the models developed using Ecotect v.5.20 and Odeon 14.00 simulation programs have been determined. The model in which the optimum reverberation time for the speech action was obtained was constructed. After the construction, reverberation time measurements have been made again. As a result of the study, the effect of surface absorptions on the improvement of reverberation time in the enclosed spaces with square plan and flat floor for speech action has been evaluated. Suggestions have been developed to control the reflective and absorption properties of all surfaces in accordance with the evaluation and improvement of reverberation time.
9 November 2021 in Archives of Thermodynamics
In the present study performance of an airflow window in removing contaminants as well as providing thermal comfort for the occupants was investigated. Both natural/mixed ventilation methods were studied and the full heating load as well as contaminant sources in the office rooms considered. Then, the local and average temperature, relative humidity, velocity as well as CO2 and dust concentration were extracted from simulation results and compared to criteria in international ventilation standards. It was found that except in the big room having 8 m×6 m flooring, natural ventilation from the airflow window can satisfy the thermal and relative humidity conditions in the international ventilation standard except for the American Society of Heating, Refrigerating and Air-Conditioning Engineers. However, the thermal comfort in the room which was measured by extended predicted mean vote could not be achieved when the window operates in the natural ventilation mode, even with a 0.4 m height opening in the small (3 m×4 m) room. Finally, results indicated that the airflow ventilation system installed in small and medium offices operation can provide indoor condition in the ventilation standard either in natural/mixed operation mode consuming less energy than the traditional heating, ventilation, and air conditioning. Besides, the airflow system not only was not able to provide thermal comfort condition in the big office but also its application was not economically feasible.