1 February 2021 in Journal of Biomechanics
Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in long- and short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning.
11 February 2023 in Communications Medicine
Background: Cardiac time-resolved CT (4D-CT) acquisitions provide high quality anatomical images of the heart. However, some cardiac diseases require assessment of blood flow in the heart. Diastolic dysfunction, for instance, is diagnosed by measuring the flow through the mitral valve (MV), while in atrial fibrillation, the flow through the left atrial appendage (LAA) indicates the risk for thrombus formation. Accurate validated techniques to extract this information from 4D-CT have been lacking, however. Methods: To measure the flow rate though the MV and the LAA from 4D-CT, we developed a motion tracking algorithm that performs a nonrigid deformation of the surface separating the blood pool from the myocardium. To improve the tracking of the LAA, this region was deformed separately from the left atrium and left ventricle. We compared the CT based flow with 4D flow and short axis MRI data from the same individual in 9 patients. Results: For the mitral valve flow, good agreement was found for the time span between the early and late diastolic peak flow (bias: <0.1 s). The ventricular stroke volume is similar compared to short-axis MRI (bias 3 ml). There are larger differences in the diastolic peak flow rates, with a larger bias for the early flow rate than the late flow rate. The peak LAA outflow rate measured with both modalities matches well (bias: −6 ml/s). Conclusions: Overall, the developed algorithm provides accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA compared to 4D flow MRI.
1 March 2024 in American Journal of Physiology-Heart and Circulatory Physiology
We developed a new comprehensive approach to atrial blood component analysis that includes both conduit flow and residual volume and compared the flow components of atrial fibrillation (AF) patients in sinus rhythm with controls. Conduit and reservoir flow were similar between the groups, whereas components with longer residence time in the left atrium were increased in the AF group. This could add to the pathophysiological understanding of atrial diseases and possibly clinical management.
10 July 2025 in The Journal of Physiology
Left atrial appendage occlusion (LAAO) is an emerging treatment option for cardioembolic stroke risk reduction in patients with sustained or paroxysmal atrial fibrillation (AF). How LAAO affects the atrial blood flow field during sinus rhythm has not yet been defined. Here, we simulated virtual LAAO in 21 paroxysmal AF patients and eight controls in normal sinus rhythm using computational fluid dynamics (CFD). We found that in AF patients, LAAO reduces the amount of blood that remains in the LA for more than three cardiac cycles to levels similar to the control group with intact LAA. However, there is a large variation among the AF group and even after LAAO the patients with highest stasis still had a relatively large amount of blood remaining in the LA over multiple cycles. This remaining blood is predominately located close to the site of LAA occlusion, a region where occlusion device related thrombi are known to occur. Accurate patient stratification is important to identify the impacts of LAAO on the patient specific haemodynamics. image Key points: Patients with atrial fibrillation (AF) have an increased risk for stroke. One underlying mechanism for this is that thrombi form in the left atrial appendage (LAA). To reduce the risk of thrombi forming in the LAA, it can be closed with an occlusion device. In this study, we simulated how the blood flows in the left atrium of AF patients before and after a virtual LAA occlusion and compared it to a control group. We found that LAA occlusion could reduce the time blood stays in the left atrium in most patients with AF to similar levels as the control group. But in some patients, blood stagnated for a long time even after LAA occlusion. Our results help us understand why thrombi can form even after LAA occlusion and might help to predict which patients could benefit most from LAA occlusion.