Jayaseelan Dhakshinamoorthy

Jayaseelan Dhakshinamoorthy

Auto-generated profile, based on publicly available information

Jayaseelan Dhakshinamoorthy

PSG Institute of Advanced Studies, Coimbatore, Tamil Nadu, INDIA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2016 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
JDJayaseelan Dhakshinamoorthy
Jayaseelan Dhakshinamoorthy
BPBiji Pullithadathil
Biji Pullithadathil

18 May 2020 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
DPDinesh Veeran Ponnuvelu
Dinesh Veeran Ponnuvelu
JDJayaseelan Dhakshinamoorthy
Jayaseelan Dhakshinamoorthy
APArun K. Prasad
Arun K. Prasad
SDSandip Kumar Dhara
Sandip Kumar Dhara
MKMohammed Kamruddin
Mohammed Kamruddin
BPBiji Pullithadathil
Biji Pullithadathil

4 March 2020 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
VRVishnuraj Ramakrishnan
Vishnuraj Ramakrishnan
KNKeerthi G. Nair
Keerthi G. Nair
JDJayaseelan Dhakshinamoorthy
Jayaseelan Dhakshinamoorthy
KRK. R. Ravi
K. R. Ravi
BPBiji Pullithadathil
Biji Pullithadathil
Porous n – p type ultra-long ZnO@Bi 2 O 3 heterojunction nanorods have been synthesized through a solvothermal method and their complex charge transport characteristics pertaining to NO 2 gas sensing properties have been investigated.

1 September 2015 in RSC Advances
Verified
Journal Article
Closed access
PDF file
KNKeerthi G. Nair
Keerthi G. Nair
DJD. Jayaseelan
D. Jayaseelan
BPBiji Pullithadathil
Biji Pullithadathil
A highly stable conducting nanoink based on silver ultra-long nanowires (Ag ULNWs) was developed by a self-seeding polyol method with controlled doping of silver acetate for flexible electronics applications. Ionic diffusion followed by the reduction of Ag+ ions was found to have a significant role on the network conductivity by reducing the contact resistance of the conducting patterns. Crack-free, bendable conductive patterns could be produced by a direct-writing approach with superior conductivity. The electrical properties of the nanowire ink patterns have been analysed with respect to pattern length, time and temperature. A two dimensional (2D) rectangular resistive network model has been adopted to depict the role of network density, percolation density and contact resistance of these conducting nanowire networks. Further, various electronic arts and circuit interconnects were drawn on cellulose paper substrates using a direct-writing approach and their performances have been successfully manifested.

17 July 2019 in Journal of Breath Research
Verified
Journal Article
Closed access
PDF file
SASukhananazerin Abdulla
Sukhananazerin Abdulla
JDJayaseelan Dhakshinamoorthy
Jayaseelan Dhakshinamoorthy
VMVijay Mohan
Vijay Mohan
DPDINESH V P
DINESH V P
VKVenkataraman Krishnan Kallidaikuruchi
Venkataraman Krishnan Kallidaikuruchi
BPBiji Pullithadathil
Biji Pullithadathil
This work demonstrates the development of Ag@polyaniline/multi-walled carbon nanotube nanocomposite-based sensor strips and a suitable integrated electronic read-out system for the measurement of trace-level concentrations of ammonia (NH 3 ). The sensor is optimized under various operating conditions and the resulting sensor exhibited an enhanced response (32% for 2 ppm) with excellent selectivity. Stable performance was observed towards NH 3 in the presence of high concentrations of CO 2 (>40 000 ppm), simulated and real breath samples. A suitable electronic sensor read-out system has also been designed and developed based on multi-scale resistance-to-voltage conversion architecture, processed by a 32-bit microcontroller which is operatable over a wide range of sensor resistance (1 kΩ to 200 MΩ). As a proof of concept, integration of gas-sensing strips with the electronic read-out system was tested with various levels of NH 3 (2 ppm as critical and 2 ppm as threshold), which is important for clinical breath analyzer applications. The developed prototype device can be readily incorporated into a portable, low-cost and non-invasive point-of-care breath NH 3 detection unit for portable pre-diagnostic breath analyzer applications.

5 November 2018 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
JDJayaseelan Dhakshinamoorthy
Jayaseelan Dhakshinamoorthy
APArun K. Prasad
Arun K. Prasad
SDSandip Dhara
Sandip Dhara
BPBiji Pullithadathil
Biji Pullithadathil