1 February 2022 in IEEE Journal of Biomedical and Health Informatics
Neuron tracing from optical image is critical in understanding brain function in diseases. A key problem is to trace discontinuous filamentary structures from noisy background, which is commonly encountered in neuronal and some medical images. Broken traces lead to cumulative topological errors, and current methods were hard to assemble various fragmentary traces for correct connection. In this paper, we propose a graph connectivity theoretical method for precise filamentary structure tracing in neuron image. First, we build the initial subgraphs of signals via a region-to-region based tracing method on CNN predicted probability. CNN technique removes noise interference, whereas its prediction for some elongated fragments is still incomplete. Second, we reformulate the global connection problem of individual or fragmented subgraphs under heuristic graph restrictions as a dynamic linear programming function via minimizing graph connectivity cost, where the connected cost of breakpoints are calculated using their probability strength via minimum cost path. Experimental results on challenging neuronal images proved that the proposed method outperformed existing methods and achieved similar results of manual tracing, even in some complex discontinuous issues. Performances on vessel images indicate the potential of the method for some other tubular objects tracing.
26 October 2021 in Frontiers in Neuroanatomy
3D volume imaging has been regarded as a basic tool to explore the organization and function of the neuronal system. Foreground estimation from neuronal image is essential in the quantification and analysis of neuronal image such as soma counting, neurite tracing and neuron reconstruction. However, the complexity of neuronal structure itself and differences in the imaging procedure, including different optical systems and biological labeling methods, result in various and complex neuronal images, which greatly challenge foreground estimation from neuronal image. In this study, we propose a robust sparse-smooth model (RSSM) to separate the foreground and the background of neuronal image. The model combines the different smoothness levels of the foreground and the background, and the sparsity of the foreground. These prior constraints together contribute to the robustness of foreground estimation from a variety of neuronal images. We demonstrate the proposed RSSM method could promote some best available tools to trace neurites or locate somas from neuronal images with their default parameters, and the quantified results are similar or superior to the results that generated from the original images. The proposed method is proved to be robust in the foreground estimation from different neuronal images, and helps to improve the usability of current quantitative tools on various neuronal images with several applications.
29 January 2026 in IEEE Access
Images captured in low-light conditions often suffer from overexposure, amplified noise, and uneven illumination. Supervised enhancement methods tend to overfit specific scenes, while unsupervised ones struggle to model degradations without reference images. To address these challenges, we propose a zero-reference Retinex framework. This framework integrates bilateral grid learning with an illumination-guided cross-attention mechanism, enabling stronger multi-scale feature extraction and enhanced illumination perception. We construct a three-dimensional spatial–luminance representation to model illumination distributions and introduce an illumination-guided cross-attention module to enhance feature alignment. Dynamic slicing and modulation further refine illumination, improving global consistency while preserving structural details. On the LOLv1 dataset, our method achieves 19.91 dB PSNR and reduces LPIPS by 14.34% compared with recent zero-reference approaches. Extensive experiments across multiple public datasets further confirm the strong PSNR, SSIM, and LPIPS performance of our method over state-of-the-art approaches.
25 September 2024 in Journal of Innovative Optical Health Sciences
This paper aims to develop a nonrigid registration method of preoperative and intraoperative thoracoabdominal CT images in computer-assisted interventional surgeries for accurate tumor localization and tissue visualization enhancement. However, fine structure registration of complex thoracoabdominal organs and large deformation registration caused by respiratory motion is challenging. To deal with this problem, we propose a 3D multi-scale attention VoxelMorph (MA-VoxelMorph) registration network. To alleviate the large deformation problem, a multi-scale axial attention mechanism is utilized by using a residual dilated pyramid pooling for multi-scale feature extraction, and position-aware axial attention for long-distance dependencies between pixels capture. To further improve the large deformation and fine structure registration results, a multi-scale context channel attention mechanism is employed utilizing content information via adjacent encoding layers. Our method was evaluated on four public lung datasets (DIR-Lab dataset, Creatis dataset, Learn2Reg dataset, OASIS dataset) and a local dataset. Results proved that the proposed method achieved better registration performance than current state-of-the-art methods, especially in handling the registration of large deformations and fine structures. It also proved to be fast in 3D image registration, using about 1.5 s, and faster than most methods. Qualitative and quantitative assessments proved that the proposed MA-VoxelMorph has the potential to realize precise and fast tumor localization in clinical interventional surgeries.