19 October 2017 in IOP Conference Series: Earth and Environmental Science
The structure of the hybrid harmonic compensation device adapted for variable speed drive system is proposed in the paper. The main feature of the proposed device is the usage of common direct current link both for inverter of power frequency converter and for inverter of active part of the hybrid device. This decision allows to decrease the cost of active part of the proposed hybrid device. The proposed hybrid device is firstly intended for voltage and current harmonic determination and elimination. A mathematical model of generalized industrial power supply system with nonlinear load and the proposed hybrid device was developed by means of Matlab Simulink software. During simulation the proper efficiency of the proposed hybrid device is shown in different modes of voltage and current harmonic compensation.
1 March 2018 in IOP Conference Series: Materials Science and Engineering
1 June 2022 in International Journal of Power Electronics and Drive Systems (IJPEDS)
The article highlights and optimizes a controller for the single ended primary inductance converter (SEPIC) direct current-direct current (DC-DC) converter. The SEPIC converter adjusts a range of dc input voltages and delivers a constant and stable output voltage. Three different models of the SEPIC converter are presented in order to derive its transfer function. Being a 4th order, an approximation method for the reduction of this transfer function to 2nd and 1st order is implemented. Two methods for controlling the converter are presented, the first one is based on guessing techniques and the second explains the design steps of the controller based on the internal model control (IMC). Furthermore, an improvement on the IMC controller is proposed and results were shown and discussed. IMC is based on integrating the “process model” in the control operation of the actual system. By using an approximation of the original transfer function of the system, it is expected that the IMC control will be able to achieve the desired results. Control schemes of the SEPIC will be presented and results will be shown. The response of the controller was tested with mathematical models for batteries and supercapacitors in MATLAB, as non-ideal DC-sources, and results were presented.
1 June 2019 in IOP Conference Series: Materials Science and Engineering
1 November 2019 in IOP Conference Series: Materials Science and Engineering
The article describes the relevance of the problem of increasing the efficiency of fuel and energy complexes, based on the energy strategy of Russia for 2030. A review of various methods of air cooling for a more intense combustion process in a gas turbine plant is carried out and the most optimal one is chosen. The paper presents a model of the system of automatic control of the air cooling of the heat exchanger of a gas turbine unit to ensure the conditions of the nominal mode of operation when weather conditions change.
15 November 2018 in IOP Conference Series: Earth and Environmental Science
Actuality of highest harmonics hybrid compensation in currents and voltages was gained to improve efficiency of oil fields power supply equipment. A positive effect is achieved due to implementation of active and passive filters in centralized and autonomous power supply systems with high percentage of non-linear loads. There was an observed structure of the hybrid electrotechnical complex based on a parallel active filter and two passive filters that were set for elimination of the 5th and 7th current harmonics that were generated by non-linear load represented as a power converter. This scheme was adapted for the use with a frequency-controlled electric drive due to adjustment of the parallel filter DC link and non-linear load of the frequency converter. There were developed mathematical and computer simulation models of the observed hybrid electrotechnical complex with the common DC link for the conditions of autonomous power supply at the oil field object. The control system of the autonomous electrotechnical complex hybrid part was develop. It contains phase converters and a dead space width disposal variable of relay controllers during generation of control pulses. Analyses of non-sinusoidal level adjustment efficiency of voltage and current signals were conducted after simulation of the hybrid electrotechnical complex. The calculations of technical-and-economic indices and efficiency usage were performed taking into account implementation of the hybrid electrotechnical complex into industrial power supply systems. The obtained results prove that the developed hybrid electrotechnical complex with the common DC link for the autonomous power supply of oil fields in the DG networks is efficient, reliable and can be installed in the existing power supply systems.