Alessandro Caimi

Alessandro Caimi

Auto-generated profile, based on publicly available information

Alessandro Caimi

Civil Engineering and Architecture Department, Università degli Studi di Pavia, Pavia, Italy

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2022 in Journal of Digital Imaging
Verified
Journal Article
Closed access
PDF file
SSSimone Saitta
Simone Saitta
FSFrancesco Sturla
Francesco Sturla
ACAlessandro Caimi
Alessandro Caimi
ARAlessandra Riva
Alessandra Riva
MPMaria Chiara Palumbo
Maria Chiara Palumbo
ARAlberto Redaelli
Alberto Redaelli

4 November 2022 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
ENRICA CHIESAENRICA CHIESA
ENRICA CHIESA
MBMarco Bellotti
Marco Bellotti
ACAlessandro Caimi
Alessandro Caimi
Bice ContiBice Conti
Bice Conti
Dorati RossellaDorati Rossella
Dorati Rossella
FAFerdinando Auricchio
Ferdinando Auricchio

1 October 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
ACAlessandro Caimi
Alessandro Caimi
FSFrancesco Sturla
Francesco Sturla
FPFrancesca Romana Pluchinotta
Francesca Romana Pluchinotta
LGLuca Giugno
Luca Giugno
FSFrancesco Secchi
Francesco Secchi
ARAlberto Redaelli
Alberto Redaelli

7 April 2024 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
ENRICA CHIESAENRICA CHIESA
ENRICA CHIESA
ACAlessandro Caimi
Alessandro Caimi
MBMarco Bellotti
Marco Bellotti
AGAlessia Giglio
Alessia Giglio
Bice ContiBice Conti
Bice Conti
Ida GentaIda Genta
Ida Genta
Lipid-based nanocarriers have emerged as helpful tools to deliver sensible biomolecules such as proteins and oligonucleotides. To have a fast and robust microfluidic-based nanoparticle synthesis method, the setup of versatile equipment should allow for the rapid transfer to scale cost-effectively while ensuring tunable, precise and reproducible nanoparticle attributes. The present work aims to assess the effect of different micromixer geometries on the manufacturing of lipid nanocarriers taking into account the influence on the mixing efficiency by changing the fluid–fluid interface and indeed the mass transfer. Since the geometry of the adopted micromixer varies from those already published, a Design of Experiment (DoE) was necessary to identify the operating (total flow, flow rate ratio) and formulation (lipid concentration, lipid molar ratios) parameters affecting the nanocarrier quality. The suitable application of the platform was investigated by producing neutral, stealth and cationic liposomes, using DaunoXome®, Myocet®, Onivyde® and Onpattro® as the benchmark. The effect of condensing lipid (DOTAP, 3–10–20 mol%), coating lipids (DSPE-PEG550 and DSPE-PEG2000), as well as structural lipids (DSPC, eggPC) was pointed out. A very satisfactory encapsulation efficiency, always higher than 70%, was successfully obtained for model biomolecules (myoglobin, short and long nucleic acids).

1 April 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
ARAlessandra Riva
Alessandra Riva
FSFrancesco Sturla
Francesco Sturla
ACAlessandro Caimi
Alessandro Caimi
SPSilvia Pica
Silvia Pica
DGDaniel Giese
Daniel Giese
EVEmiliano Votta
Emiliano Votta

Verified
Journal Article
Open access
PDF file
Pasquale TotaroPasquale Totaro
Pasquale Totaro
ACAlessandro Caimi
Alessandro Caimi
GFGiulia Formenton
Giulia Formenton
MMMartina Musto
Martina Musto
MSMartina Schembri
Martina Schembri
FAFerdinando Auricchio
Ferdinando Auricchio
Background: In this study, we examined and compared ex vivo mechanical properties of aortic walls in patients with bicuspid (BAV) and tricuspid (TAV) aortic valve aortopathy to investigate if the anatomical peculiarities in the BAV group are related to an increased frailty of the aortic wall and, therefore, if a different surgical cutoff point for ascending aortic replacement could be reasonable in such patients. Methods: Ultimate stress tests were performed on fresh aortic wall specimens harvested during elective aortic surgery in BAV (n. 33) and TAV (n. 77) patients. Three mechanical parameters were evaluated at the failure point, under both longitudinal and circumferential forces: the peak strain (Pstr), peak stress (PS), and maximum elastic modulus (EM). The relationships between the three mechanical parameters and preoperative characteristics were evaluated, with a special focus on evaluating potential risk factors for severely impaired mechanical properties, cumulatively and comparatively (BAV vs. TAV groups). Results: The patient populations were inhomogeneous, as BAV patients reached surgical indication, according to the maximum aortic dilatation, at a younger age (58 ± 15 vs. 64 ± 13; p = 0.0294). The extent of the maximum aortic dilatation was, conversely, similar in the two groups (52 ± 4 vs. 54 ± 7; p = 0.2331), as well as the incidences of different phenotypes of aortic dilatation (with the ascending aorta phenotype being the most frequent in 81% and 66% of the BAV and TAV patients, respectively (p = 0.1134). Cumulatively, the mechanical properties of the aortic wall were influenced mainly by the orientation of the force applied, as both PS and EM were impaired under longitudinal stress. An age of >66 and a maximum dilatation of >52 mm were shown to predict severe Pstr reduction in the overall population. Comparative analysis revealed a trend of increased mechanical properties in the BAV group, regardless of the position, the force orientation, and the phenotype of the aortic dilatation. Conclusions: BAV aortopathy is not correlated with impaired mechanical properties of the aortic wall as such. Different surgical cutoff points for BAV aortopathy, therefore, seem to be unjustified. An age of >66 and a maximum aortic dilatation of >52 mm, however, seem to significantly influence the mechanical properties of the aortic wall in both groups. These findings, therefore, could suggest the need for more accurate monitoring and evaluation in such conditions.