Michael T. K. Bramson

Michael T. K. Bramson

Auto-generated profile, based on publicly available information

Michael T. K. Bramson

Department of Biomedical Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York 12180, United States

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Electrospinning
Verified
Journal Article
Open access
PDF file
ADAnthony R. D’aMato
Anthony R. D’aMato
MBMichael T. K. Bramson
Michael T. K. Bramson
DCDavid T. Corr
David T. Corr
DPDevan Puhl
Devan Puhl
RGRyan J. Gilbert
Ryan J. Gilbert
JJJed Johnson
Jed Johnson
Electrospinning is a robust material fabrication method allowing for fine control of mechanical, chemical, and functional properties in scaffold manufacturing. Electrospun fiber scaffolds have gained prominence for their potential in a variety of applications such as tissue engineering and textile manufacturing, yet none have assessed the impact of solvent retention in fibers on the scaffold’s mechanical properties. In this study, we hypothesized that retained electrospinning solvent acts as a plasticizer, and gradual solvent evaporation, by storing fibers in ambient air, will cause significant increases in electrospun fiber scaffold brittleness and stiffness, and a significant decrease in scaffold toughness. Thermogravimetric analysis indicated solvent retention in PGA, PLCL, and PET fibers, and not in PU and PCL fibers. Differential scanning calorimetry revealed that polymers that were electrospun below their glass transition temperature (Tg) retained solvent and polymers electrospun above Tg did not. Young’s moduli increased and yield strain decreased for solventretaining PGA, PLCL, and PET fiber scaffolds as solvent evaporated from the scaffolds over a period of 14 days. Toughness and failure strain decreased for PGA and PET scaffolds as solvent evaporated. No significant differences were observed in the mechanical properties of PU and PCL scaffolds that did not retain solvent. These observations highlight the need to consider solvent retention following electrospinning and its potential effects on scaffold mechanical properties.

19 June 2020 in Biomacromolecules
Verified
Journal Article
Closed access
Kening LangKening Lang
Kening Lang
SBSomdatta Bhattacharya
Somdatta Bhattacharya
ZNZhuoyuan Ning
Zhuoyuan Ning
RSRegina J. Sánchez-Leija
Regina J. Sánchez-Leija
MBMichael T. K. Bramson
Michael T. K. Bramson
Richard A. GrossRichard A. Gross
Richard A. Gross

24 March 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MBMichael T. K. Bramson
Michael T. K. Bramson
SHSarah K. Van Houten
Sarah K. Van Houten
DCDavid Corr
David Corr
Tendon, ligament, and skeletal muscle are highly organized tissues that largely rely on a hierarchical collagenous matrix to withstand high tensile loads experienced in activities of daily life. This critical biomechanical role predisposes these tissues to injury, and current treatments fail to recapitulate the biomechanical function of native tissue. This has prompted researchers to pursue engineering functional tissue replacements, or dysfunction/disease/development models, by emulating in vivo stimuli within in vitro tissue engineering platforms—specifically mechanical stimulation, as well as active contraction in skeletal muscle. Mechanical loading is critical for matrix production and organization in the development, maturation, and maintenance of native tendon, ligament, and skeletal muscle, as well as their interfaces. Tissue engineers seek to harness these mechanobiological benefits using bioreactors to apply both static and dynamic mechanical stimulation to tissue constructs, and induce active contraction in engineered skeletal muscle. The vast majority of engineering approaches in these tissues are scaffold-based, providing interim structure and support to engineered constructs, and sufficient integrity to withstand mechanical loading. Alternatively, some recent studies have employed developmentally inspired scaffold-free techniques, relying on cellular self-assembly and matrix production to form tissue constructs. Whether utilizing a scaffold or not, incorporation of mechanobiological stimuli has been shown to improve the composition, structure, and biomechanical function of engineered tendon, ligament, and skeletal muscle. Together, these findings highlight the importance of mechanobiology and suggest how it can be leveraged to engineer these tissues and their interfaces, and to create functional multitissue constructs.

1 April 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DKDavid Kingsley
David Kingsley
CMCaitlin H. McCleery
Caitlin H. McCleery
CJChristopher D.L. Johnson
Christopher D.L. Johnson
MBMichael T.K. Bramson
Michael T.K. Bramson
DRDeniz Rende
Deniz Rende
DCDavid Corr
David Corr

30 March 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
SHSarah K. Van Houten
Sarah K. Van Houten
MBMichael T. K. Bramson
Michael T. K. Bramson
DCDavid Corr
David Corr
Bioreactors are commonly used to apply biophysically relevant stimulations to tissue-engineered constructs in order to explore how these stimuli influence tissue development, healing, and homeostasis, and they offer great flexibility because key features of the stimuli (e.g., duty cycle, frequency, amplitude, and duration) can be controlled to elicit a desired cellular response. However, most bioreactors that apply mechanical and electrical stimulations do so to a scaffold after the construct has developed, preventing study of the influence these stimuli have on early construct development. To enable such exploration, there is a need for a bioreactor that allows the direct application of mechanical and electrical stimulation to constructs as they develop. Herein, we develop and calibrate a bioreactor, based on our previously established modified Flexcell system, to deliver precise mechanical and electrical stimulation, either independently or in combination, to developing scaffold-free tissue constructs. Linear calibration curves were established, then used to apply precise dynamic mechanical and electrical stimulations, over a range of physiologically relevant strains (0.50%, 0.70%, 0.75%, 1.0%, and 1.5%) and voltages (1.5 and 3.5 V), respectively. Following calibration, applied mechanical and electrical stimulations were not statistically different from their desired target values and were consistent whether delivered independently or in combination. Concurrent delivery of mechanical and electrical stimulation resulted in a negligible change in mechanical (<2%) and electrical (<1%) values, compared to their independently delivered values. With this calibrated bioreactor, we can apply precise, controlled, reproducible mechanical and electrical stimulations, alone or in combination, to scaffold-free, tissue-engineered constructs as they develop.

25 April 2022 in Biomacromolecules
Verified
Journal Article
Closed access
Kening LangKening Lang
Kening Lang
HQHa’aNi-Belle Quichocho
Ha’aNi-Belle Quichocho
SBSarah P. Black
Sarah P. Black
MBMichael T. K. Bramson
Michael T. K. Bramson
RLRobert Linhardt
Robert Linhardt
Richard A. GrossRichard A. Gross
Richard A. Gross