Denis Schenk

Denis Schenk

Auto-generated profile, based on publicly available information

Denis Schenk

ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
DSDenis Schenk
Denis Schenk
MIMichael Indermaur
Michael Indermaur
MSMathieu Simon
Mathieu Simon
BVBenjamin Voumard
Benjamin Voumard
PVPeter Varga
Peter Varga
PZPhilippe Zysset
Philippe Zysset
HR-pQCT based micro finite element (μFE) analyses are considered as "gold standard" for virtual biomechanical analyses of peripheral bone sites such as the distal segment of radius and tibia. An attractive alternative for clinical use is a homogenized finite element method (hFE) based on constitutive models, because of its much shorter evaluation times and modest computational resource requirements. Such hFE models have been experimentally validated for the distal segment of the radius, but neither for the distal segments of the tibia nor for both measurement sites together. Accordingly, the aim of the present study was to refine and experimentally validate an hFE processing pipeline for in vivo prediction of bone strength and stiffness at the distal segments of the radius and the tibia, using only one unified set of material properties. An existing hFE analysis procedure was refined in several aspects: 1) to include a faster evaluation of material orientation based on the mean surface length (MSL) method, 2) to distinguish cortical and trabecular bone compartments with distinct material properties and 3) to directly superimpose material properties in mixed phase elements instead of densities. Based on an existing dataset of the distal segment of fresh-frozen radii (double sections 20.4 mm, n = 21) and a newly established dataset of the distal segment of fresh-frozen tibiae (triple sections, 30.6 mm, n = 25), a single set of material properties was calibrated on the radius dataset and validated on the tibia dataset by comparing hFE stiffness and ultimate load with respective experimental results, obtained by compressing the samples on a servo-hydraulic testing machine at a monotonic and quasi-static displacement rate up to failure. Using the identified set of material properties, the hFE-predicted stiffness and failure load were in excellent agreement with respective experimental results at both measurement sites (radius stiffness R2 = 0.93, slope = 1.00, intercept = 479 N/mm2/radius ultimate load: R2 = 0.97, slope = 1.00, intercept = 679 N; tibia stiffness R2 = 0.96, slope = 1.01, intercept = -1027 N/mm2/tibia ultimate load: R2 = 0.97, slope = 1.04, intercept = 394 N; combined dataset stiffness R2 = 0.95, slope = 1.01, intercept = -230 N/mm2/combined dataset ultimate load: R2 = 0.97, slope = 1.03, intercept = 495 N). In conjunction with unified BV/TV calibration, the established hFE pipeline accurately predicts experimental stiffness and ultimate load of distal multi-sections at the radius and tibia. Processing time for non-linear analysis was substantially reduced compared to previous μFE and hFE methods but could be further minimized by estimating bone strength based on a fast and linear analysis like as is currently done with μ FE.

7 December 2022 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
DSDenis Schenk
Denis Schenk
PZPhilippe Zysset
Philippe Zysset
The microstructure of trabecular bone is known to adapt its morphology in response to mechanical loads for achieving a biomechanical homeostasis. Based on this form–function relationship, previous investigators either simulated the remodeling of bone to predict the resulting density and architecture for a specific loading or retraced physiological loading conditions from local density and architecture. The latter inverse approach includes quantifying bone morphology using computed tomography and calculating the relative importance of selected load cases by minimizing the fluctuation of a tissue loading level metric. Along this concept, the present study aims at identifying an optimal, personalized, multiaxial load case at the distal section of the human radius using in vivo HR-pQCT-based isotropic, homogenized finite element (hFE) analysis. The dataset consisted of HR-pQCT reconstructions of the 20 mm most distal section of 21 human fresh-frozen radii. We simulated six different unit canonical load cases (FX palmar–dorsal force, FY ulnar–radial force, FZ distal–proximal force, MX moment about palmar–dorsal, MY moment about ulnar–radial, MZ moment about distal–proximal) using a simplified and efficient hFE method based on a single isotropic bone phase. Once we used a homogeneous mean density (shape model) and once the original heterogeneous density distribution (shape + density model). Using an analytical formulation, we minimized the deviation of the resulting strain tensors ε(x) to a hydrostatic compressive reference strain ε0, once for the 6 degrees of freedom (DOF) optimal (OPT) load case and for all individual 1 DOF load cases (FX, FY, FZ, MX, MY, MZ). All seven load cases were then extended in the nonlinear regime using the scaled displacements of the linear load cases as loading boundary conditions (MAX). We then compared the load cases and models for their objective function (OF) values, the stored energies and their ultimate strength using a specific torsor norm. Both shape and shape + density linear-optimized OPT models were dominated by a positive force in the z-direction (FZ). Transversal force DOFs were close to zero and mean moment DOFs were different depending on the model type. The inclusion of density distribution increased the influence and changed direction of MX and MY, while MZ was small in both models. The OPT load case had 12–15% lower objective function (OF) values than the FZ load case, depending on the model. Stored energies at the optimum were consistently 142–178% higher for the OPT load case than for the FZ load case. Differences in the nonlinear response maximum torsor norm ‖t‖ were heterogeneous, but consistently higher for OPT_MAX than FZ_MAX. We presented the proof of concept of an optimization procedure to estimate patient-specific loading conditions for hFE methods. In contrast to similar models, we included canonical load cases in all six DOFs and used a strain metric that favors hydrostatic compression. Based on a biomechanical analysis of the distal joint surfaces at the radius, the estimated load directions are plausible. For our dataset, the resulting OPT load case is close to the standard axial compression boundary conditions, usually used in HR-pQCT-based FE analysis today. But even using the present simplified hFE model, the optimized linear six DOF load case achieves a more homogeneous tissue loading and can absorb more than twice the energy than the standard uniaxial load case. The ultimate strength calculated with a torsor norm was consistently higher for the 6-DOF nonlinear model (OPT_MAX) than for the 1-DOF nonlinear uniaxial model (FZ_MAX). Defining patient-specific boundary conditions may decrease angulation errors during CT measurements and improve repeatability as well as reproducibility of bone stiffness and strength estimated by HR-pQCT-based hFE analysis. These results encourage the extension of the present method to anisotropic hFE models and their application to repeatability data sets to test the hypothesis of reduced angulation errors during measurement.