Martina Cihova

Martina Cihova

Auto-generated profile, based on publicly available information

Martina Cihova

Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Acta Materialia
Verified
Journal Article
Closed access
MCM. Cihova
M. Cihova
RSR. Schäublin
R. Schäublin
LHL.B. Hauser
L.B. Hauser
SGS.S.A. Gerstl
S.S.A. Gerstl
CSC. Simson
C. Simson
JLJörg Löffler
Jörg Löffler

1 December 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
MCM. Cihova
M. Cihova
EME. Martinelli
E. Martinelli
PSP. Schmutz
P. Schmutz
AMA. Myrissa
A. Myrissa
RSR. Schäublin
R. Schäublin
JLJörg Löffler
Jörg Löffler

1 September 2020 in Acta Biomaterialia
Verified
Journal Article
Open access
PHPatrick Holweg
Patrick Holweg
LBLeopold Berger
Leopold Berger
MCMartina Cihova
Martina Cihova
NDNicholas Donohue
Nicholas Donohue
BCBernhard Clement
Bernhard Clement
Annelie-Martina WeinbergAnnelie-Martina Weinberg
Annelie-Martina Weinberg
Over the last decade, demand has increased for developing new, alternative materials in pediatric trauma care to overcome the disadvantages associated with conventional implant materials. Magnesium (Mg)-based alloys seem to adequately fulfill the vision of a homogeneously resorbable, biocompatible, load-bearing and functionally supportive implant. The aim of the present study is to introduce the high-strength, lean alloy Mg‒0.45Zn‒0.45Ca, in wt.% (ZX00), and for the first time investigate the clinical applicability of screw osteosynthesis using this alloy that contains no rare-earth elements. The alloy was applied in a growing sheep model with osteotomized bone (simulating a fracture) and compared to a non-osteotomy control group regarding degradation behavior and fracture healing. The alloy exhibits an ultimate tensile strength of 285.7 ± 3.1 MPa, an elongation at fracture of 18.2 ± 2.1%, and a reduced in vitro degradation rate compared to alloys containing higher amounts of Zn. In vivo, no significant difference between the osteotomized bone and the control group was found regarding the change in screw volume over implantation time. Therefore, it can be concluded that the fracture healing process, including its effects on the surrounding area, has no significant influence on degradation behavior. There was also no negative influence from hydrogen-gas formation on fracture healing. Despite the proximal and distal screws showing chronologically different gas release, the osteotomy showed complete consolidation.

29 July 2019 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
NKNicole Kleger
Nicole Kleger
MCMartina Cihova
Martina Cihova
KMKunal Masania
Kunal Masania
ASAndré R. Studart
André R. Studart
JLJörg Löffler
Jörg Löffler

5 September 2019 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
MCMartina Cihova
Martina Cihova
PSPatrik Schmutz
Patrik Schmutz
RSRobin Schaeublin
Robin Schaeublin
JLJörg Löffler
Jörg Löffler

1 October 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
JSJulie Soderlind
Julie Soderlind
MCMartina Cihova
Martina Cihova
RSRobin Schäublin
Robin Schäublin
SRSubhash Risbud
Subhash Risbud
JLJörg Löffler
Jörg Löffler